32 <strong>MicroLogix</strong> <strong>1400</strong> <strong>Programmable</strong> <strong>Controllers</strong>Working VoltageWorking Voltage for 1766-L32AWA/ADescriptionPower Supply Input toBackplane IsolationInput Group to BackplaneIsolationInput Group to Input GroupIsolationOutput Group to BackplaneIsolationOutput Group to OutputGroup IsolationRecommendationVerified by one of the following dielectric tests: 1836V AC for 1 second or2596V DC for 1 second265V AC Working Voltage (IEC Class 2 reinforced insulation)Verified by one of the following dielectric tests:1517V AC for 1 second or2145V DC for 1 second132V AC Working Voltage (IEC Class 2 reinforced insulation)Verified by one of the following dielectric tests:1517V AC for 1 second or2145V DC for 1 second132V AC Working Voltage (basic insulation)Verified by one of the following dielectric tests: 1836V AC for 1 second or2596V DC for 1 second265V AC Working Voltage (IEC Class 2 reinforced insulation)Verified by one of the following dielectric tests: 1836V AC for 1 second or2596V DC for 1second265V AC Working Voltage (basic insulation), 150V AC Working Voltage (IECClass 2 reinforced insulation)Working Voltage for 1766-L32BWA/ADescriptionPower Supply Input toBackplane IsolationInput Group to BackplaneIsolation and Input Group toInput Group IsolationOutput Group to BackplaneIsolationOutput Group to OutputGroup IsolationRecommendationVerified by one of the following dielectric tests:1836V AC for 1 second or2596V DC for 1 second265V AC Working Voltage (IEC Class 2 reinforced insulation)Verified by one of the following dielectric tests: 1100V AC for 1 second or1697V DC for 1 second75V DC Working Voltage (IEC Class 2 reinforced insulation)Verified by one of the following dielectric tests: 1836V AC for 1 second or2596V DC for 1 second265V AC Working Voltage (IEC Class 2 reinforced insulation).Verified by one of the following dielectric tests: 1836V AC for 1 second or2596V DC for 1 second265V AC Working Voltage (basic insulation) 150V Working Voltage (IEC Class 2reinforced insulation)Publication 1766-IN001A-EN-P - July 2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!