110Section 1General <strong>Requirements</strong> For Electric <strong>Service</strong>1.4.4.3 Owner Notice of <strong>Electrical</strong> DefectsAn Owner Notice of <strong>Electrical</strong> Defects is issued by the <strong>SaskPower</strong> <strong>Electrical</strong> Inspections Division to the owner oroccupant of a premise to make the installation comply with the Code.1.4.4.4 Electric <strong>Service</strong> Disconnection OrderWhen orders to correct defects or hazards are not complied with, the Supervisor <strong>Electrical</strong> Inspector can issue anElectric <strong>Service</strong> Disconnection Order to cut off service on a specific date. <strong>SaskPower</strong> shall disconnect the service inquestion on the date specified unless arrangements have been made with the <strong>SaskPower</strong> <strong>Electrical</strong> Inspections Division.Reconnection of the service shall only be made upon instruction from the <strong>SaskPower</strong> <strong>Electrical</strong> Inspections Division.1.4.5 VA Demand<strong>SaskPower</strong> utilizes VA demand metering on certain rates. Consumers affected by VA demand metering and a poorpower factor are well advised to consider power factor correction for their service.1.4.6 Seals and LocksTo permit access to various equipment by <strong>SaskPower</strong> employees only, seals and locks are placed on the supplyequipment components, where located on the line side of the <strong>SaskPower</strong> meter. Examples of this equipment includesplitters, instrument transformer compartments, meters, metering compartments, conduit fittings, and Consumer's servicebox (without fuses). <strong>Service</strong> boxes containing Consumer fuses will not be sealed so as to provide free access to thefuses. Removal of a seal or lock contravenes the Power Corporation Act. Penalties, enforceable by law, may beimposed as stipulated by the Power Corporation Act.Should it be necessary to break seals to perform electrical wiring alterations, <strong>SaskPower</strong> must either remove the seal, orupon receipt of advance notification, authorize the seal(s) removal. <strong>SaskPower</strong> shall be notified by the contractor whenthe work is completed to reseal the service. Upon completion of the work <strong>SaskPower</strong> will reseal the installation.1.4.7 Consumer InstrumentationConsumer's relays, instruments or other devices shall not be connected in <strong>SaskPower</strong> revenue metering circuits and shallnot be mounted on or in any meter enclosures, instrument transformer enclosures or any other equipment supplied foruse by <strong>SaskPower</strong>.1.4.8 <strong>Electrical</strong> Protection of Consumer Equipment<strong>SaskPower</strong> shall not assume responsibility for the electrical protection of Consumer-owned equipment, including thatfor single phasing protection. <strong>Electrical</strong> protection shall be installed as per the Code.1.4.9 AccessFor all installations of <strong>SaskPower</strong> equipment (such as metering equipment or service cable terminations), <strong>SaskPower</strong>staff shall have access to all such equipment for the purpose of changing, servicing, testing and reading. Where accessto the equipment is unobtainable due to locked doors, the local <strong>SaskPower</strong> office shall be provided with a key. Whenmutually agreeable, <strong>SaskPower</strong> will supply a lock box for storage of the key.November, 2004Electric <strong>Service</strong> <strong>Requirements</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!