10.07.2015 Views

Centricity PACS Version 1.0 CONFORMANCE STATEMENT for ...

Centricity PACS Version 1.0 CONFORMANCE STATEMENT for ...

Centricity PACS Version 1.0 CONFORMANCE STATEMENT for ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GEMS INFORMATION TECHNOLOGIESCENTRICITY <strong>PACS</strong> <strong>1.0</strong> <strong>CONFORMANCE</strong> <strong>STATEMENT</strong>REV 0, MAY 2002 IIS FP 10617Attribute Name Tag Change ReasonPatient ID (0010,0020) SOP Instance is associated to another patient, orwrong Patient ID is included in the data setPatient’s Name * (0010,0010) Wrong data in data set. Most likely manual input.Patient’s Birth Date (0010,0030) Wrong data in data set. Most likely manual input.Patient’s Sex (0010,0040) Wrong data in data set. Most likely manual input.Other Patient Ids (0010,1000) Data corrected or supplementedStudy Instance UID ** (0020,000D) SOP Instance is associated to another studyAccession Number (0008,0050) Wrong data in data set. Most likely manual input.Study Date (0008,0020) Study with multiple steps per<strong>for</strong>med on differentdevice, <strong>Centricity</strong> <strong>PACS</strong> takes the earliest studydate / time.Study Time (0008,0030) See above.Referring Physician's Name (0008,0090) Wrong data in data set. Most likely manual input.Study Description (0008,1030) Study with multiple steps per<strong>for</strong>med on differentdevice, <strong>Centricity</strong> <strong>PACS</strong> can only take one.Requested Procedure ID (0040,1001) Data corrected or supplementedSeries Instance UID ** (0020,000E) Bad Series Instance UID in the data setSeries Number (0020,0011) User specific reasons.SOP Instance UID ** (0008,0018) Bad SOP Instance UID in the data setImage Number (0020,0013) User specific reasons.Number of Images inAcquisition(0020,1002) User specific reasons.TABLE 4-5: DATA ELEMENT COERCION OF THE SOP INSTANCES* : Patient Name may be multi-valued and encoded with extended character sets, see Section3.1.3.** : If these UID values are changed, the original UID values are saved in the data set as privatetags, see Appendix B.4.2.4 Supported Uses of SOP InstancesUsually, <strong>Centricity</strong> <strong>PACS</strong> is applied in the radiology practice <strong>for</strong> image data management, storage,archiving, display, print, and distribution.The DICOM Con<strong>for</strong>mance Statement in<strong>for</strong>mation specifies which DICOM Storage SOP Classes aresupported by the <strong>Centricity</strong> DICOM Server as SCP, i.e., they can be received by <strong>Centricity</strong> <strong>PACS</strong>.This does not automatically confirms that all SOP Instances can be displayed or printed or processed incertain application.This section gives the in<strong>for</strong>mation of the supported uses of the received SOP Instances in <strong>Centricity</strong><strong>PACS</strong>.4.2.4.1 Data Storage<strong>Centricity</strong> <strong>PACS</strong> will store all successfully received SOP Instances in its on-line storage subsystem.4–38

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!