thermocouples, for example, change physically at 1300<br />
°C and then can no longer achieve repeatable readings.<br />
For example, forging steel.<br />
• Highly aggressive materials can be measured without<br />
contact and thus without damage to the sensor. For<br />
example, acids in chemical processes.<br />
• Objects can be measured with pyrometers even though<br />
they cannot be physically reached. <strong>Pyrometer</strong>s are<br />
compact units that can be installed nearly anywhere. All<br />
they need is a clear line of sight to the object.<br />
For example, measuring the temperature of metals<br />
during the heating process.<br />
• Objects conducting electricity may be measured without<br />
danger of short-circuiting and without danger to the user.<br />
For example, testing the temperature of electric terminals<br />
in switch boxes.<br />
• Heat is transferred very slowly and incompletely to the<br />
sensor of a contact measuring instrument from poor heatconducting<br />
objects, from low heat capacity objects and<br />
from objects which have a small mass. This method<br />
produces inaccuracies, but they can be eliminated by<br />
using a non-contact device. For example, thin foils and<br />
plastic film.<br />
• Great distances are overcome by appropriate optics. For<br />
example, flare stack monitors.<br />
• It is possible to measure through windows so long as the<br />
windowpane material is compatible 2). For example,<br />
measuring temperatures in furnaces and in a vacuum.<br />
2) see page 51<br />
<strong>Pyrometer</strong> <strong>Handbook</strong><br />
aggressive materials<br />
inaccessible objects<br />
electricity conducting<br />
objects<br />
poor heat conductors<br />
small mass, low heat<br />
great distances<br />
viewing windows<br />