CHANNEL 1CHANNEL 2CHANNEL 3CHANNEL 4CHANNEL 5CHANNEL 6CHANNEL 7CHANNEL 8CHANNEL 9CHANNEL 10CHANNEL 11CHANNEL 12ALARMCONTINUITYSTATUSOFF: NORMALRED: LEAK DETECTEDOFF: NORMALRED: CABLE DAMAGEGREEN: NORMALRED: ALARM DEACTIVATEDOFF: UNUSED CHANNELALARM(PUSH TO TEST)RTTG<strong>TraceTek</strong> <strong>Multiple</strong> <strong>Channel</strong> <strong>Alarm</strong> <strong>Module</strong>The <strong>TraceTek</strong> TTG multiple channel alarmmodule is designed for use with all<strong>TraceTek</strong> sensing cables to detect fluidleaks. The TTG can independently monitorup to 12 individual sensing cables(4 and 12 channel models available).Simple operationThe module display includes LEDs foreach channel. In the event of a leak, thealarm sounds and the LED indicates thechannel where the leak occurred. Theoperator silences the alarm by pressingthe external SILENCE BUZZER button.The four pole TTG alarm relay can actuateoptional remote alarm devices.Reliable performanceThe module's faceplate features threeLEDs for each channel to clearly indicatethe system condition:• STATUS - power/activation for channel• CONTINUITY - sensing circuit integrity• ALARM - presence of leaksAny loss of system integrity, whethercaused by an interruption of power or acut in a cable, will be indicated by themodule panel display and relay output.External and internal test features allowthe user to check module functions.Rugged designThe metal enclosure of the TTG alarmmodule can be surface or flush-mounted.The module enclosure can be locked torestrict access by unauthorized personnel.The alarm buzzer can be silencedfrom outside the module enclosure. The95-decibel alarm is easily heard abovethe operating noise of process equipment.The module operates on 120 or240 Vac.12 in.(305 mm)4 in.(102 mm)<strong>TraceTek</strong>1234567PUSH TO SILENCEBUZZER14 in.(356 mm)8MONITORING SYSTEMALARM LIGHT:9101112CONTINUITY LIGHT:STATUS LIGHT:Hasp forpadlockTechnical InformationSensing cable compatibilityAll <strong>TraceTek</strong> sensing cablesMaximum length of sensing cable 100 ft (30 m)Temperature rating32°F to 105°F (0°C to 40°C)Metal enclosure NEMA 13Audible alarm95 decibelsSupply voltage120/240 Vac; 50/60 HzPower consumption TTG-4 25 VATTG-12 41 VARelayActivated by leak or continuity alarmin any channelOne 4PDT, Form C relay3 A rating at 120 Vac/28 VdcOrdering InformationCatalog NumberTTG-4TTG-12Description4 channel alarm module12 channel alarm module


TTG <strong>Multiple</strong> <strong>Channel</strong> <strong>Alarm</strong> <strong>Module</strong>Internal <strong>Module</strong> FunctionsA BC D E F G HRESETABCDEFTerminal stripConnects the four wires from a sensing cable to channel inalarm module.Test buttonInitiates test of individual channel functions.<strong>Channel</strong> SettingsDIP switches determine setting for the channel:- one switch turns power for channel on or off- three switches adjust for sensing cable typeALARM indicator LEDRed LED illuminates on channel which has detected thepresence of liquid (a leak).CONTINUITY fault indicator LEDYellow LED illuminates on channel which has detected acable break—a loss of continuity in the sensing circuit.STATUS indicator LED• Illuminates green on channel powered and connected toalarm circuitry• Illuminates red on channel powered but disconnectedfrom alarm circuitry (with switch G)• Off on unused channel (turned off with DIP switch C)GStatus switchConnects/disconnects channel from alarm circuitry.IHIMaster reset buttonResets alarm circuitry.<strong>Alarm</strong> relaysRelay contacts allow actuation of optional remote alarm devices.Approval InformationISO 9001RLISTEDRaychem CorporationCommercial & IndustrialInfrastructure Division300 Constitution DriveMenlo Park, CA 94025-1164Tel (800) 545-6258Fax (800) 611-2323www.raychem.comThe TTG module is UL Listed for use in Class I Division 2, Groups A, B, C, and D HazardousLocations. <strong>TraceTek</strong> sensing cables connected to the module may be located in Class I Division 1,Groups A, B, C, and D Hazardous Locations.TypicalSystemTTGLeader or jumper cableOrdinary area orClass I, Div. 2Hazardous LocationThe <strong>TraceTek</strong> products group is a part of Raychem Chemelex Division.Chemelex Division is ISO 9001 certified.Ordinary area orClass I, Div. 2 Hazardous Location orClass I, Div. 1 Hazardous Location<strong>TraceTek</strong> sensing cableAll information, including illustrations, is believed to be reliable. Users, however, should independently evaluate thesuitability of each product for their application. Raychem makes no warranties as to the accuracy or completeness ofthe information, and disclaims any liability regarding its use. Raychem’s only obligations are those in the RaychemStandard Terms and Conditions of Sale for this product, and in no case will Raychem be liable for any incidental,indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications aresubject to change without notice. In addition, Raychem reserves the right to make changes—without notification toBuyer—to materials or processing that do not affect compliance with any applicable specification.© 1987, 1996 Raychem Corporation Printed in USA H53053 11/96 <strong>TraceTek</strong> is a trademark of Raychem Corporation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!