(29)NOTE: The 120 volt mode is not affected bythe delay cycle. Any time the refrigerator issupplied with 120 volts AC the unit will befully operational on the AC mode, even if therefrigerator is in a delay cycle.THE 120 VOLT MODEIS NOT AFFECTED BYTHE DELAY CYCLE(30)After the customers have reached the campsiteand have parked the <strong>RV</strong>, they plug the 120volt shore line into a power source. At thispoint the unit will operate it’s ingrainedpriority system.(31)The added benefit of this system is if the ACpower source is lost during a storm or the like,the refrigerator will automatically switch tothe LP gas mode during the power failure. Assoon as the AC power is re-established, theA.E.S. system will switch again to 120 volts.(32)Now that we have a basic understanding ofhow a customer will use an A.E.S. refrigerator,let’s take a look at some of the other featuresincorporated into the control system. First, wehave the L.E.D. lamp assembly which willprovide the customer with useful informationin regard to the operation of the refrigerator.A-6-9