(103)Refer to the RM3801 switch diagnosistroubleshooting section of the A.E.S.Diagnostic <strong>Manual</strong> for a detailed explanationon how to troubleshoot these switches. (Seepages A-8-l to A-8-5)(104)The next component to diagnose is thesolenoid valve’s internal winding. The A.E.S.control system uses the solenoid winding toprovide a ground circuit to the printed circuitboard for all modes of operation. If thesolenoid winding is defective, the refrigeratorwill not operate on any heat source.(105)To check the solenoid winding, remove allpower sources from the refrigerator, AC andDC and unplug the connector at the solenoidby pulling firmly outward.Measure the resistance value across the upperand lower terminals on the valve assembly.The proper valve should be 20 ohms withtolerance range of 10 percent. Values outsidethe tolerance range or no ohms reading wouldindicate a defective solenoid valve winding.A-6-36