10.07.2015 Views

Arc Protection Relay REA 10_ - APE Distribuidor ABB

Arc Protection Relay REA 10_ - APE Distribuidor ABB

Arc Protection Relay REA 10_ - APE Distribuidor ABB

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Arc</strong> <strong>Protection</strong> <strong>Relay</strong> <strong>REA</strong> <strong>10</strong>_1MRS750929-MBGTable 13: Environmental testsSpecified service temperature range-<strong>10</strong>...+55°CTransport and storage temperature range-40...+70°COperation in dry heat conditions According to IEC 60068-2-2Operation in dry cold conditions According to IEC 60068-2-1Damp heat test cyclic According to IEC 60068-2-30r.h. >95%, t = 20...55°CStorage temperature test According to IEC 60068-2-48Table 14: Encapsulation<strong>REA</strong> <strong>10</strong>1 Degree of protection, IEC 60529 IP 20Weightabout 4.6 kg<strong>REA</strong> <strong>10</strong>3 Degree of protection, IEC 60529 IP 20Weightabout 1.1 kg<strong>REA</strong> <strong>10</strong>5 Degree of protection, IEC 60529 IP 20Weightabout 1.1 kg<strong>REA</strong> <strong>10</strong>7 Degree of protection, IEC 60529 IP 20Weightabout 1.0 kgTable 15: Insulation testsDielectric tests according to IEC 60255-5Impulse voltage test according to IEC 60255-5Insulation resistance according to IEC 60255-52 kV, 50 Hz, 1 min.5 kV, 1.2/50 µs, 0.5 J><strong>10</strong>0 MΩ, 500 V DCTable 16: Electromagnetic compatibility testsEMC immunity test level meets the requirements listed below:1 MHz burst disturbance test according to IEC 60255-22-1, class III:Common modeDifferential modeElectrostatic discharge test according to IEC 6<strong>10</strong>00-4-2, class IV andANSI/IEEE C37.90.3-200:For contact dischargeFor air discharge2.5 kV1 kV8 kV15 kVRadio-frequency electromagnetic field disturbance test according to IEC 6<strong>10</strong>00-4-3 andIEC 60255-22-3:Amplitude-modulated:Frequency fField strength EPulse-modulated:Frequency fField strength ERadio frequency disturbance test according toIEC 6<strong>10</strong>00-4-6 and IEC 60255-22-6:Conducted, common modeFast transient disturbance tests according toIEC 60255-22-4 and IEC 6<strong>10</strong>00-4-4Surge immunity test according to IEC 6<strong>10</strong>00-4-5 and IEC 60255-22-5:Aux. voltage input, trip outputs:Line-to-lineLine-to-earthSignal contacts (IRF), current inputs, RESET input:Line-to-lineLine-to-earthElectromagnetic emission tests according to EN 55011 and IEC 60255-25:80...<strong>10</strong>00 MHz<strong>10</strong> V/m (rms)900 MHz<strong>10</strong> V/m (rms)<strong>10</strong> V, 150 kHz...80 MHz4 kV2 kV4 kV1 kV2 kV<strong>10</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!