Watchdog Changeover Unit User Guide - Trilogy Communications
Watchdog Changeover Unit User Guide - Trilogy Communications
Watchdog Changeover Unit User Guide - Trilogy Communications
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6. SPECIFICATION<strong>Trilogy</strong> <strong>Communications</strong> Limited<strong>Watchdog</strong>Note. All measurements are made assuming, where appropriate, that the various offsets controlledfrom the front panel are set to zero unless otherwise stated. All signal measurements are made withinputs and outputs terminated in 75Ω unless otherwise stated.6.1 370-10-00 ACTIVE BOARDReturn LossIsolation between A and B channelsInsertion Loss< -35dB to 10 MHz< -30dB @ 30 MHz> -60dB to 10 MHz< 1dB6.2 370-11-00 PASSIVE BOARDReturn LossIsolation between A and B channels< -35dB to 10 MHz< -30dB @ 30 MHz> -60dB to 10 MHz<strong>User</strong> <strong>Guide</strong> Issue 1.00 Page 27 of 28