10.07.2015 Views

pH 500 meter product bulletin - Oakton Instruments

pH 500 meter product bulletin - Oakton Instruments

pH 500 meter product bulletin - Oakton Instruments

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>pH</strong>/mV/°C<strong>pH</strong> <strong>500</strong> MeterOur most economical benchtop <strong>meter</strong>—a new standard in its pricerange! The large dual display shows <strong>pH</strong> or mV, plus temperature.Low cost plus high performancethis <strong>meter</strong> offers laboratory-quality readingsfor a very economical costISO 9001v e n d o rCERTIFIED<strong>pH</strong> MeasurementDual display shows both <strong>pH</strong>(or mV) and temperatureplus mode indicators and annunciators tosignal <strong>meter</strong> statusThree point <strong>pH</strong> calibration withauto buffer recognitioncalibrate at 4.01, 7.00 and 10.00 for highaccuracy across the entire measuring rangeSwitch from <strong>pH</strong> to mV readingswith a button pressFeatures 0.1 mV resolution forORP and ISE measurementsthis is the only <strong>meter</strong> in its price class thatoffers 0.1 mV resolution—a requirement forISE readingsyear3 warranty<strong>meter</strong> onlySelectable manual or automatictemperature compensationfor high accuracy with or without atemperature sensorAnalog recorder outputcreate hard copies of your readingsHold functionfreezes reading until you can record it“Ready” indicatorshows when the reading is stableIdeal for student usethis easy-to-use <strong>meter</strong> is so economical,you’ll want several for your lab!Fully diagrammed manual,plus slide-out instruction cardfor quick referenceTop: The <strong>pH</strong> <strong>500</strong> <strong>meter</strong> is designed for laboratorybenchtop use. It is less sensitive to electronic noise,which gives you stable, repeatable readings.Bottom left: Use the recorder output to create hardcopy records of your data.Bottom right: This simple-to-use <strong>meter</strong> is ideal forroutine measurements or student use.Laboratory benchtop readings at an economical price! The <strong>pH</strong> <strong>500</strong> <strong>meter</strong> providesstable, accurate measurements in <strong>pH</strong>, mV and temperature. It has high 0.1 mV resolution for ORP and ISEmeasurements—it’s the only <strong>meter</strong> in its price class to offer this feature. Since this <strong>meter</strong> so easy to use,you’ll be ready to take readings in minutes!The <strong>pH</strong> <strong>500</strong> <strong>meter</strong> features a large dual display that shows <strong>pH</strong> (or mV) and temperature readings, and awater-resistant membrane keypad. It includes a slide-out instruction card that stores underneath the <strong>meter</strong>for quick reference.The <strong>pH</strong> <strong>500</strong> <strong>meter</strong> is supported by a full selection of OAKTON calibration buffers, electrodes and accessories.See the back of this sheet for ordering information and complete specifications....setting the standard, again and again


Large dual display shows<strong>pH</strong> or mV plus temperature readings,and indicators which signalfunction and <strong>meter</strong> status.<strong>pH</strong> <strong>500</strong> Benchtop Meter• Applications •General Applications: Ideal for all kinds of water quality and chemical testing in the laboratory.Suitable for most ASTM and EPA test procedures.Education Applications: Ideal for students at all levels; suitable for all types of chemistry lab and ecology studies.Industrial Applications: Boiling water/cooling water testing, food processing water testing, process and wastewater testing in metal finishing,printing and chemical industries. Also used in aquarium and hydroponics industries.Back panel has quickconnections for electrode,ATC probe, and recorder output.Slide-out instruction cardwith trouble shooting tips and akeypad reference stores neatly atbottom of <strong>meter</strong>.• Specifications •Type <strong>pH</strong> mV TemperatureRange 0.00 to 14.00 <strong>pH</strong> ±400 mV and ±1999 mV 0 to 100°CResolution 0.01 <strong>pH</strong> 0.1 mV from ±400 mV, 1 mV beyond ±400 mV 0.1°CAccuracy ±0.01 <strong>pH</strong> ±0.2 mV from ±400 mV,±2 mV beyond ±400 mV 0.5°CCalibration Up to three calibration points (4.01, 7.00, 10.00) — Offset up to ±5°CConnectors BNC BNC mini phono plugPower: 9 VDC, <strong>500</strong> mA; using AC adapter (included);choose from 110 VAC, 60 Hz or 220 VAC, 50 Hz models.AC adapter is CSA and UL listed.Input impedance: >10 12 ΩTemperature Compensation:Selectable Manual or Automatic from 0 to 100°CRecorder output: ±1999 mV (directly proportional to input)Recorder output connector: mini pin (subminiature phono plug)Display: Dual display of measurement with temperature andmode annunciatorsError messages: Diagnose operator error, electrode error,and <strong>meter</strong> error. Pull-out instruction card decodes messageOperating Temperature: 0 to 50°C, non condensing humidityDimensions:Meter: 9" x 7" x 2.375" (23 x 18 x 6 cm)Boxed: 15.5" x 10" x 3.5" (39 x 25 x 9 cm)Weight: Meter only 1.25 lbs (0.6 kg); Boxed 3 lbs (1.4 kg)Sturdy benchtop electrode holderkeeps your probe steady and awayfrom the sides of your container(order separately).Calibration solutions are availablein economical bottles or convenientpouches with a tear-off top(order separately).• Ordering Information •<strong>pH</strong> <strong>500</strong> MetersAll <strong>meter</strong>s include AC adapter and instructions.Meter onlyWD-35617-02 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 110 VACWD-35617-07 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 220 VACMeter with single-junction <strong>pH</strong> electrode (WD-35801-00) andseparate temperature probe (WD-35615-05)WD-35617-00 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 110 VACWD-35617-05 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 220 VACMeter with “All in One” combination temperature sensor/single-junction <strong>pH</strong> electrode (WD-35801-71)WD-35617-03 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 110 VACWD-35617-08 <strong>pH</strong> <strong>500</strong> <strong>meter</strong>, 220 VAC<strong>pH</strong> “Singles” Calibration Buffer PouchesEach single-use pouch contains 20 ml of fresh calibration solution(see picture below left). ±0.01 <strong>pH</strong> accuracy at 25°C. Certified toNIST traceable standards. Shpg wt 1 lb (0.5 kg). Box of 20.WD-35653-01 <strong>pH</strong> “Singles”, 4.01WD-35653-02 <strong>pH</strong> “Singles”, 7.00WD-35653-03 <strong>pH</strong> “Singles”, 10.00WD-35653-00 <strong>pH</strong> “Singles”, rinse waterWD-35653-04 <strong>pH</strong> “Singles”, assortment pack,5 each of <strong>pH</strong> 4.01; 7.00; 10.00 and rinse water<strong>pH</strong> Calibration Buffer Solution Bottles1 pint of calibration solution each. ±0.01 <strong>pH</strong> accuracy at 25°C.Certified to NIST traceable standards. Shpg wt 1.3 lbs (0.6 kg).WD-00654-00 <strong>pH</strong> 4.01 calibration bufferWD-00654-04 <strong>pH</strong> 7.01 calibration bufferWD-00654-08 <strong>pH</strong> 10.01 calibration bufferElectrodesWD-35805-04 Laboratory <strong>pH</strong> electrode, double junction,glass body, refillable. 110 mm x 12 mm dia.WD-35801-00 <strong>pH</strong> electrode, single junction;epoxy body, 146 mm L x 12 mm diaWD-35615-05 Temperature (ATC) probe,304 SS, 85 mm LWD-35801-71 “All-in-One” combination <strong>pH</strong>/temperatureprobe, single junction, epoxy body, 147 x 12 mm diaWD-35801-72 “All-in-One” combination <strong>pH</strong>/temperatureprobe, double junction, epoxy body, 147 x 12 mm diaWD-35805-13 ORP electrode, single junction,epoxy body, 146 mm L x 12 mm diaWD-35805-15 ORP electrode, double junction,epoxy body, 146 mm L x 12 mm diaWD-35617-50 Benchtop electrode holder, 360° pivot,holds four electrodes (up to 12 mm dia) and temperature probe.Box dimensions: 9"L x 15"W x 10"H. Shpg wt 4 lbsOAKTON offers a wide selection of <strong>pH</strong> and ORP electrodes; contact your OAKTON distributor for more information.• ORDER FROM •Bulletin <strong>pH</strong> C1R2Printed in the U.S.A. 8/01. OAKTON TM Reg. #1,692,543. Patent Des. 371,748. We reserve the right to make changes, improvements and modifications to<strong>product</strong>s shown. All prices subject to change without notice. OAKTON <strong>Instruments</strong> are available only through authorized OAKTON distributors.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!