A:INCCALIBRATE< INC > < LRV > < URV >B : OUTPUT ADJImportantURV1LRV < Zero adjustment >A-1: CALIBRATELRV ×××.××%×××.× kPa< ENT > < CL >CLENTCLA-1: CALIBRATELRV ×××.××%×××.× kPaCHNG OK? < ENT/CL > 3ENTA-2: CALIBRATINGLRV ×××.××%×××.× kPa< Span adjustment >A-3: CALIBRATEURV ×××.××%×××.× kPa< ENT > < CL >CLA-3: CALIBRATEURV ×××.××%×××.× kPaCHNG OK? < ENT/CL > 6A-4: CALIBRATINGURV ×××.××%×××.× kPaCLENTENTPress LRV or URV at display of 1 .When the following is displayed, it means that calibration can not be made becauseMenu No. H: LINEARIZE is effective. In this case, set INVALID on the panel of No. H: LIN-EARIZE.1. Span adjustment should be performed after zero adjustment is completed.2. When the actual input exceeds the adjustable range, [NOT CALB ] is displayed.In this case, adjustment is required again.Adjustable rangeZero adjustment: Within ±40% of maximum spanSpan adjustment: Within ±20% of calibrated span3. When the adjustment point does not meet the following condition,[SETTING ERR] is displayed. In this case, adjustment is required again.Adjustment point setting condition–1.000%CS (*) PL 100.000%CS (*) 0.000%CS (*) PH 110.000%CS (*)PL =PH =(Lower adjustment point) - LRVURV - LRV(Higher adjustment point) - LRVURV - LRV× 100× 1002457A-1:CALIBRATECan’t proceed.Set Linearizeinvalid (*) : CS (Calibrated Span) is equal to measuring range.Zero/span adjustmentZero and span are adjustable by applyingan actual pressure.When pressing under display 1the screen for zero adjustment 2appears, and that for span adjustment 5appears when pressing .Under display 2 , after applying actualpressure equal to zero point, press two times. Zero adjustment willbe over.When adjustment is made at any pointother than zero, input the pressure valueat that point at the display of 2 , thenpress the key at the display of 3while applying a corresponding pressureto the transmitter.Under display 5 , after applying actualpressure equal to desired span, press two times. Span adjustmentwill be over.When adjustment is made at any pointother than span, input the pressure valueat that point at the display of 5 , thenpress the key at the display of 6while applying a corresponding pressureto the transmitter.17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!