Pump Start/Master ValveValveCommonPump Start RelayValve Common WireMaster ValveCAUTION: To avoid possible equipment damage, do not connect pump starter directlyto the controller. A 24V, 0.5A (maximum) relay must be used for this connection.Flow Sensor Connection1. Route the flow sensor wires into the controller cabinet.2. Connect the flow sensor wires to the flow-enabled expansion module as follows: Black tonegative (–) and Red to positive (+).NOTE: Flow Sensor wiring polarity must be correct to enable operation.Black (–) Red (+) MasterValveFlow SensorMaster Valve3. If the master valve circuit is used, connect either solenoid wire to the MV terminal and theremaining wire to either common terminal (C).NOTE: The master valve circuit is controlled by operation of the corresponding expansionmodule only.23