10.07.2015 Views

LC-2010HT

LC-2010HT

LC-2010HT

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SpecificationsSpecificationsSpecifications of <strong>LC</strong>-<strong>2010HT</strong>Item <strong>LC</strong>-<strong>2010HT</strong> (228-45103-3X) <strong>LC</strong>-<strong>2010HT</strong> (228-45102-3X)PumpPump typeFlow rate setting rangeFlow rate accuracyFlow rate precisionPressure display accuracyPlunger cleaningSerial dual pluger, micro volume (10μL on primary side, 5μL on secondary)0.001-5 mL / min [1.0-35 Mpa / 145-5076psi]±1% or ±2μL / min, whichever is larger (1mL / min, 3-10.0MPa / 435-1450psi, water, ambient temperatureat 20°C, except in gradient solvent delivery), ±2% or ± 2μL / min, whichever is larger(except above condition and in gradient solvent delivery)±0.075% RSD or 0.02min SD, whichever is larger (0.05-2mL / min, 1.0-35Mpa / 145-5076psi, methanol,ambient temperature at 20°C)±2% or ±0.5MPa, whichever is largerAutomatic rinsing mechanism as standard equipmentLPGE Number of solvents andsetting rangeConcentration accuracyConcentration precisionUp to 4 solvents0-100%, 0.1% step±0.5%(0.1-2mL / min, 1.0-20.0MPa / 145-2900psi, aqueous acetone / water)±0.1%(0.1-2mL / min, 1.0-20.0MPa / 145-2900psi, aqueous acetone / water)DegasserAutosamplerTypeVolumeInjection methodInjection volume setting rangeMembrane on-line degasser, 5 lines (4x mobile phase, 1x autosampler rinsing liquid)4mL / line for mobile phase, 2mL / line for autosampler rinsing liquidFull volume injection, variable injection possible (no sample loss)0.1-100μL (standard), 1-2000μL (optional)(0.1-0.9μL in 0.1μL step, 1-2000μL in 1μL step)Samplecapacity1 mL vials1.5 mL vials350140 2104 mL vials100Microtiter platesDeep well platesInjection volume repeatabilityCarryoverInjection volume accuracyRepetition injection frequencyAnalytical run time settingInjection condition stepsOperating pressureRinsing liquid degassingMax.4 plates (up to 384 samples with 96 well or 1536 samples with 384 well plates)Max.4 plates (up to 384 samples with 96 plates)RSD < 0.3% (10μL injection)0.01% (under conditions determined by Shimadzu)±1% (50μL, n=6)1-99 / sample0.01-9999.9 min (0.01 min step)Max. 202 steps35.0MPa maximumStandardSamplecooler(<strong>LC</strong>-<strong>2010HT</strong> only)TypeTemperaturesetting rangeDirect cooling type.(For setting temperature at 4°C, ambienttemperature shall be 30°C or lower and humidity70% or lower.)Dehumidifier incorporated.4-40°C (For setting temperature at 4°C, ambienttemperature shall be 30°C or lower and humidity70% or lower.)Column OvenTypeTemperature setting rangeTemperature control precisionTemperature control rangeColumns accommodatedPreheater volumeBlock heating with preheating of the mobile phase4-60°C, 1°C step±0.1°C(Ambient temperature-15°C) -60°C2 x 250mm columns4μL (for Semi-micro), and 9μL, 2 channels16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!