10.07.2015 Views

LC-2010HT

LC-2010HT

LC-2010HT

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

OptionsOptionsOptions for <strong>LC</strong>-<strong>2010HT</strong>Description Part Number Set NoSample rack for 1mL vials (2 racks / set)Sample rack for 1.5mL vials (2 racks / set)*228-37532-91228-45409-91228-44628-91For <strong>LC</strong>-2010AHT / 2010CHT (up to 350 vials)For <strong>LC</strong>-2010AHT (up to 210 vials)For <strong>LC</strong>-2010CHT (up to 140 vials)Sample rack for 4mL vials (2 racks / set)Sample rack for Microtiter plate (2 racks / set)Sample rack for Deep-well plate (2 racks / set)Column Management Device (CMD)CMD cableOptional board228-37544-91228-37545-91228-37546-91228-37281-91228-39991228-40050-91For <strong>LC</strong>-2010AHT / 2010CHT (up to 100 vials)For <strong>LC</strong>-2010AHT / 2010CHT (up to 4 vials)For <strong>LC</strong>-2010AHT / 2010CHT (up to 4 vials)For column management (1 device for 1 column)1 cable is required for 1 <strong>LC</strong>-2010AHT / 2010CHTTo add functions of:1) BCD output of sample number2) addition of event output terminal3) analog output of pump pressure, column oven temperature,ambient temperature sensor, sample cooler temperatureRecycle valveTemperature-controlled flow cell for semi-micro HP<strong>LC</strong>2mL sample loop kitMaintenance kit without toolsMaintenance kit with tools* Sample rack for 1.5mL vials (2racks / set) is included as standard accessory.228-37383-91228-37384-91228-37548-91228-39872-96228-39872-97For solvent recyclePass length: 5mm, cell volume: 24μLFor large-volume injectionVials for AutosamplerRacksApplicable Sample VialsSample Rack for 1mL Vials11mL Glass (with PE cap)250pcs / set(228-39699-91)21.5mL Glass (with cap,silicone rubber septum)100pcs / set(228-15652-92)31mL PP*(with PE cap)200pcs /set(228-31600-91)40.2mL PP*(with PE cap)100pcs / set(228-35217-91)Sample Rack for 1.5mL Vials51.1mL Glass*(with cap, silicone rubberseptum)100pcs / set(228-21283-91)60.3mL Glass*(with metal spacer, cap, silicone rubber septum)100pcs / set (228-16847-92)(Vials without spacer as spare)100pcs / set (228-16850-91)Sample Rack for 4mL Vials74mL Glass(with cap, silicone rubberseptum)100pcs / set(228-21287-91)84mL PP*(with PE cap)100pcs / set(228-31537-91)90.3mL Glass*(with spring to be inserted in 4mL vial)100pcs / set (228-21284-91)(Vials without spring as spare)100pcs / set (228-21285-91)• All vials commonly used with the SIL-20A / 10ADVP / 10AF / 10Ai / HT can be used with the <strong>LC</strong>-<strong>2010HT</strong>.• Regarding vials, microtiter plates, and deep-well plates marked*, the set temperature and actual temperature might differ due to differences in shape or in the thermalconductivity of the materials.• Silicon rubber septa (with PTFE cover) (228-26718-93,100pcs) or PTFE septa (228-15655-91,100pcs) can be chosen for vials No. 2, 5, and 6.• Silicon rubber septa (with PTFE cover) (228-21290-91,100pcs) or PTFE septa (228-23469-91,100pcs) can be chosen for vials No. 7, 8, and 9.• Please use commercially available microtiter plates and deep-well plates.• PP: polypropylene, PE: polyethylene18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!