10.07.2015 Views

LC-2010HT

LC-2010HT

LC-2010HT

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

UV DetectorControllerItem <strong>LC</strong>-<strong>2010HT</strong> (228-45103-3X) <strong>LC</strong>-<strong>2010HT</strong> (228-45102-3X)Light sourceDeuterium lamp,Low pressure mercury lamp (for wavelength accuracy check)Wavelength rangeBandwidthWavelength accuracyWavelength reproducibilityCellCell temperature controlDriftNoise levelLinearitySimultaneous dual wavelengthmeasurementSignal outputDisplayMemory mediaInput / output terminals190-600nm8nm±1nm±0.1nm10mm, 8μLStandard (Setting temperature: High, Low, and OFF, 3 steps)1 x 10 -4 AU / h (250nm, air in cell, constant, room temperature)*±0.25 x 10 -5 AU (2 sec. time, constant, 250nm, air in cell)*~2.5AUSelectable, two wavelengths in 190-370nm or 371-600nm2 channelsBacklit <strong>LC</strong>D display (320 x 240 dots)3.5 inch floppy disk drive (disk format, 2HD, MS-DOS)2 x external inputs, 2 x external outputs (+3 option),1 x optical link (for Chromatopac),1 x RS-232C (for connection to PC),2 x detector signal output (for integrator),BCD output of sample number (option)File numberMethod: 20 filesSystem preparation: 10 filesShut-down: 2 filesSequence: 1 fileSolvent delivery unit controlFlow rate, Concentration, Max. pressure, Min. pressure, Linear, Step, Exponential functionAuto sampler controlSample injection volume, Number of injections, Analysis time, Analysis file numberColumn oven controlDetector controlSelf diagnostics, Safety featureAutomation functionApplicable solventpH rangeLiquid contact surface materialsOperating Ambient temperature range, humidityPower requirementsSizeWeight*Condition according to ASTM E1657-96Oven temperature, Max. temperatureWavelength, Time constant, Lamp ON / OFF, Integrator output rangeMemory check, Max / Min pressure, Oven max. temperature, Lamp current, motor error check, Leaksensor, Lamp cover sensor, Lamp housing max. temperatureAuto start-up, Auto shut-down, Baseline stability autojudgment,Auto validation (Wavelength, Lamp energy, Solvent delivery pulsation, Column temperature, Absorbance,Baseline drift, Baseline noise, Pressure limit, Gradient accuracy)Auto purge, Cell auto recognition, Column management (option)Memory check, Max / Min pressure, Oven max. temperature, Lamp current, Motor revolution monitor,Leak sensor, Lamp cover sensor, Lamp housing max. temperatureOrganic solvents (except fluorine solvent, e.g. HFIPA),Aqueous solution and mixture of diluted acid or base(except halo-acids, e.g. hydrochloric acid)1-13 standardSUS316, Ruby, Sapphire, PTFE, Hasteloy C, PEEK, Trifluoroethylene, PFA Perfluoroelastomer, Quartz,Ceramic4-35°CMax. 80% humidityAC 100V-240V, 700VA, 50 / 60HzW430 x D500 x H605 mm52kg47kg17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!