10.07.2015 Views

Health and Safety in Shearing (PDF 917kb) - WorkSafe Victoria

Health and Safety in Shearing (PDF 917kb) - WorkSafe Victoria

Health and Safety in Shearing (PDF 917kb) - WorkSafe Victoria

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Number threeRelease chutesTraditional designSheep often baulk at enter<strong>in</strong>g a release chute or gate. When this happens anyobstruction will serve as a foothold. This will mean that the shearer has to work veryhard <strong>and</strong> struggle to push the sheep out the chute or gate.How big is the problem?A good gate or chute requires no effort – the sheep just walk away or slide down.To f<strong>in</strong>d out how much force is needed when a shearer needs to push the sheep pastan obstruction, a chute was built with a small obstruction that the sheep could useas a foothold.Experienced shearers pushed sheep out the chute while the forces were measured.ResultsThe results show that the shearer has to do a lot more than just push the sheep towardthe chute. They must control a struggl<strong>in</strong>g animal. This means they must push <strong>and</strong> pull<strong>in</strong> all directions.When struggl<strong>in</strong>g with the sheep many jo<strong>in</strong>ts <strong>in</strong> the body are placed at risk.For example the forces <strong>in</strong> the back were estimated to be about 25% greater than therecognised limits.The risk of a back <strong>in</strong>jury is even greater because the shearer has been stooped overfor several m<strong>in</strong>utes.Recommended releaseThe best release is one where no effort is needed by the shearer.Chutes or level releases can be made easy to use by:1. Mak<strong>in</strong>g sure there are no obstructions (like wood nailed across the entry to thechute) that could be a foothold for the sheep.2. Mak<strong>in</strong>g the chute large enough (about 600 mm wide by 850 mm high).3. Mak<strong>in</strong>g the near side of the chute about 150 – 250 mm from the downtube.4. Cutt<strong>in</strong>g the chute about 150 mm <strong>in</strong>to the shear<strong>in</strong>g board.<strong>WorkSafe</strong> <strong>Victoria</strong> gratefully acknowledgesVIOSH AustraliaUniversity of BallaratPO Box 663Ballarat 3353Tel: 03 5327 9150Shear<strong>in</strong>g Shed Design Note<strong>Health</strong> & <strong>Safety</strong> <strong>in</strong> Shear<strong>in</strong>g 55

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!