10.07.2015 Views

Why choose a PSG furnace?

Why choose a PSG furnace?

Why choose a PSG furnace?

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical data<strong>furnace</strong> and componentsFuelMaximum input capacityMaximum output capacitywood180,000 BTU (53 kW)137,970 BTU (41 kW)Average output capacity89,680 BTU (27 kW)Integrated thermostatic controlyesOptimum efficiency 82%Average emissions5.9 grams / hour or 0,20 g/MJLoading capacityFlue spigot diameterRecommended exhaust pipe diameterType of chimney requiredRecommended chimney diameterFurnace exterior dimensionsFirebox dimensionsDoor opening dimensionsDoor typeHot air plenum dimensionsCold air plenum dimensionsAsh pan dimensionsNumber of filtersFilters dimensionsBlowerSteel thickness (firebox)Minimum clearance (front)Minimum clearance (rear)Minimum clearance (sides)Minimum clearance (ducts)Recommended service clearanceWeightColorWarrantySafety tests standardMAX CADDYup to 90 lbs (41 kg)6”6” if installed as wood or wood-electric combination7” if installed as wood-oil combination2100 O F (1150 O C)6” if installed as wood or wood-electric combination7” if installed as wood-oil combination30”W x 62”D x 50”H20 3/8”W x 26 1/4”D x 14 1/2”H15 11/16”W x 10”Hglass with cast iron frame25 7/16”W x 32 1/8”D19 15/16”W x 17 15/16”D12”W x 19 5/8”D x 2 5/8”H116”W x 20”D x 1”HG-10 blowerwith 1/2 hp motor1780 CFM (maximum at 0.20” WC) - 4 speeds3/16”48”24”6” (wood only) and 24” on the option side6” for the first 6’ with a shield at 1 1/2”, and 1” thereafter24”650 lbs (295 kg)GreenLimited lifetime warrantyCan CSA B366.1, UL 391, CAN/CSA C22.2 no 236,UL 1995, CSA B140.4, UL 727Emissions / Efficiency - test standardCSAB415.1-10Maximum log length 25”Optional electricelement: 20 kWor 25 kW.Optional hotwater loop kitfor pre-heatingdomestic water.11Max CaddyCSA B415.1 wood-oil-electric trio <strong>furnace</strong>caddy seriesTop cold air plenum optionPlenum dimensionsOptional electric elementOutput - Recommended elementOutput - Other optional elementsElement locationOptional oil burnerInput #1Input #2Burner orifice at input #1Burner orifice at input #2Pump pressure at input #1Pump pressure at input #2Efficiency at input #1Efficiency at input #2Standard burnerBurner locationOptional insulated vestibuleRecommended exhaust pipe diameterExhaust pipe locationOptional hot water loop kit for pre-heating domestic waterConnection locationConnecting pipe diameterBack-up tank volumeOptional fresh air intake adapterConnection locationConnecting pipe diameterMAX CADDY19 15/16” W x 17 15/16” DMAX CADDY20 kW / 68,000 BTU25 kW / 85,000 BTULeft or rightMAX CADDY91,000 BTU120,000 BTU0,65 70 o W (Beckett) / 0,50 70 o W (Riello)0,65 70 o W (Beckett) / 0,65 70 o W (Riello)100 PSI (Beckett) / 150 PSI (Riello)175 PSI (Beckett) / 165 PSI (Riello)Beckett (85%) / Riello (87%)Beckett (83%) / Riello (85%)BeckettLeft or rightno5“Left or rightMAX CADDYLeft or right3/4”60 gallons (227 liters)MAX CADDYRight5“Optional fresh airintake adapter.Optional Beckettoil burner.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!