142000 and 3000Wood and combination <strong>furnace</strong>s2000 and 3000 seriesWood and combination <strong>furnace</strong>s2000 and 3000 seriesBelow, a <strong>PSG</strong> 2000 wood-oil combo shown with the burner'sexhaust pipe coming out on the left side.Technical data<strong>furnace</strong> and components <strong>PSG</strong> 2000 <strong>PSG</strong> 3000FuelMaximum input capacityMaximum output capacityAverage output capacityIntegrated thermostatic controlLoading capacityFlue spigot diameterRecommended exhaust pipe diameterType of chimney requiredRecommended chimney diameterFurnace exterior dimensionsFirebox dimensionsDoor opening dimensionsDoor typeHot air plenum dimensionsCold air plenum dimensionsAsh pan dimensionsNumber of filtersFilters dimensionsBlowerSteel thickness (firebox)Minimum clearance (front)Minimum clearance (rear)Minimum clearance (sides)Minimum clearance (ducts)Recommended service clearance (blower)WeightColorWarrantyTests standardMaximum log lengthOptional fuel oil burnerInput capacityBurner orificePomp pressureStandard burnerEfficiencyBurner locationRecommended service clearance (burner)Optional insulated vestibule for burnerRecommended exhaust pipe diameterExhaust pipe locationOptional electric elementsOutput - recommended electric elementThe electric element simply slidesunderneath the firebox.woodwood75,000 BTU (21.9 kW)120,000 BTU (35.2 kW)47,250 BTU (13.9 kW) 75,600 BTU (22.2 kW)30,715 BTU (9 kW) 49,140 BTU (14.4 kW)yesyesup to 35 lbs (16 kg)up to 60 lbs (27 kg)6” 6”6”6” or 7” **2100 o F (1150 o C)2100 o F (1150 o C)6”6” or 7” **23,5”W x 46”D x 46”H26”W x 47”D x 48”H14”Wx 22”D x 12,5”H16”W x 26”D x 16”H12”W x 13”H12”W x 13”HDouble plate steelDouble plate steel22,25”W x 26,25”D24,5”W x 28,25”D22,25”W x 15,75”D24,5”W x 15,75”D12”W x 16”D x 3”H12”W x 16”D x 3”H2211”W x 20”D x 1”H12”W x 24”D x 1”H1/3 HP1/3 HPDirect driveDirect driveFour speed, 950 cfmFour speed, 1300 cfm3/16”3/16”48”48”29” recommended for servicing29” recommended for servicing24” recommended for servicing24” recommended for servicing6” for the first 6 feet and 2” thereafter6” for the first 6 feet and 2” thereafter29”29”450 lbs (205 kg)540 lbs (245 kg)GreenGreenLimited lifetime warrantyLimited lifetime warrantyCan CSA B366.1-M91, CSAB212-93,Can CSA B366.1-M91, CSAB212-93,UL391 3e Ed. rev. 1999UL391 3e Ed. rev. 199920” 24”<strong>PSG</strong> 2000 <strong>PSG</strong> 300085,000 BTU (25 kW)0,65 gal/hr.* (2,46 l/hr.)110 PSIBeckett AFG82%right24”no5”leftOutput - other optional electric elements18 kW15, 20, 25 kWElement locationRecommended service clearance (element)left24”left24”* US Gallon (1 US Gallon = 0,83 Imperial Gallon) ** 6” if installed as wood or wood-electric combination or 7” if installed as wood-oil combination15 kWBelow, a <strong>PSG</strong> 3000 wood-electric combo shown with theelectrical element accessible from the left side.91,000 BTU (27 kW)0,65 gal/hr.* (2,46 l/hr.)120 PSIBeckett AFG82%right24”yes5”left<strong>PSG</strong> 2000 <strong>PSG</strong> 300018 kW
Suspended fuel oil unit heater6500 series156500Suspended fuel oil unit heater6500 seriesRear view with direct-vent systemIdeal for commercial and industrial buildingsThe suspended <strong>PSG</strong> 6500 fuel oil unit heater is designed for commercial and industrial uses. It is a simple and reliable productthat your enterprise can count on. Even though it is designed to be suspended, the <strong>PSG</strong> 6500 can also be installed on anon-combustible stand with clearance space of 6 inches to the combustible floor material. The adjustable louvers at the front of the<strong>PSG</strong> 6500 enable you to direct the heat where you most need it.Easy to installThe <strong>PSG</strong> 6500 can be installed conventionally, i.e., with a chimney or directly through a wall with the <strong>PSG</strong> direct vent kit. This flexibilitygives you all the options whether you install your <strong>PSG</strong> 6500 in a new building or use it to replace an old space heater.Technical dataunit heater and componentsFuelType of ventingInput capacityOutput capacityBurner orificeStandard burner modelEfficiencyIntegrated thermostatic controlRecommended exhaust pipe diameterType of chimney requiredRecommended chimney diameterUnit heater exterior dimensionsBlowerSteel thickness (combustion chamber)Adjustable louversMinimum clearance (underneath the unit)Minimum clearance (front of unit)Minimum clearance (rear of unit)Minimum clearance (side of unit)Recommended service clearance (burner)WeightColorWarrantySafety tests standard* US Gallon (1 US Gallon = 0,83 Imperial Gallon)<strong>PSG</strong> 6500oilWith chimneyor direct-vent90,000 BTU (26 kW)75,000 BTU (22 kW)0,65 gal/hr.* (2,46 l/hr.)Beckett AFG83.4%yes5”L-vent for oil or <strong>PSG</strong> DV Kit5”20”W x 37”D x 39”H1/6 HP16” Dia., 22 O pitch1075 rpm / 1750 cfm16 Ga H.R.yes6”48”24”6”24”190 lbs (86 kg)greyLimited lifetime warrantyCSA B140.4 (C2001), UL731-1995Direct ventsystemNatural draftwith chimney