2. How to use ADJ Tool when replacing Lens unitMake sure to perform the following procedure after replacing the lens.A floppy disk with the lens data is bundled in the spare parts of the lens unit.How to enable USB TCC ON is the same as <strong>EX</strong>-Z750.1 Enter the TEST mode.1. Turn the power on while pressing both "BS" and "UP" buttons.2. Press "DOWN" button, "DOWN" button, "BS" button, and "MENU"button while the program version is displayed.3. Select "2.USB TCC TEST", and press "SET" button.4. Select "1. USB TCC ON", and press "RIGHT" button, "RIGHT" buttonand "SET" button.5. Turn the power OFF.2 Connect the camera to the computer by the USB cable.3 Boot "adj03ssaw" .4 Select the model name and click "Load FW " Key.• <strong>EX</strong>-<strong>S500</strong>5 Click "ADJ ALL READ", and display the data on the "adj03ssaw".6 Find the No.1163, "LCD VCOM DC".7 Write down this value(data).8 Replace the Lens unit.9 Perform the above 1 to 3.0 Select the model name and click "Load FW " Key.• <strong>EX</strong>-<strong>S500</strong>A From "File/Open", open the bundled floppy disk, and transfer the data tothe "adj03ssaw".AB Find the No.1163,"LCD VCOM DC"C Change the data to the former value.(Refer to 7).D Click "WRITE" button of "ADJ ALL".E After adjustment, change "1. USB TCC ON" to "2. USB TCC OFF".64D— 12 —