11.07.2015 Views

ZR24/7 Hazer - SXS Events

ZR24/7 Hazer - SXS Events

ZR24/7 Hazer - SXS Events

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MACHINE LAYOUT<strong>ZR24</strong>/7 <strong>Hazer</strong>USERGUIDE<strong>ZR24</strong>/7 <strong>Hazer</strong>courtesy of Event Phone: production 0870 and 080 Audio-Visual 2342 Serviceswww.sxsevents.co.uk email: enquiries@sxsevents.co.ukUSERGUIDETHE FLUID SYSTEMThe <strong>ZR24</strong>/7 <strong>Hazer</strong> uses a 2.5L container to give approximately 6 hours ofcontinuous operation at full output. Power supply voltage fluctuations shouldhave little effect on this, since the unit has automatic supply voltagecompensation for pump speed.FluidcompartmentDisplay unitDMX in/out3/5 pinRemoteinputOn/Off switchPower inletwith fuseThe machine control system uses a water based fluid to create the hazeeffect, and has adequate power to produce the maximum haze outputcontinuously.Supply voltage and frequency variations are measured and compensatedfor, within the limits of the specified operating voltage/frequency range for themodel concerned.Continuous operation gives rise to the possibility of pump damage if themachine runs out of fluid. This is overcome in the <strong>ZR24</strong>/7 <strong>Hazer</strong> by using anindirect electronic fluid sensing system, ensuring that the pump is shut downwhen the fluid level is too low. The display will show a Flu Out message towarn the user that the machine is shut down due to lack of fluid. The indirectnature of the system means that it is slow to respond, and may take up to 10minutes to recognize a low fluid condition. However, the fluid systemcomponents are capable of running dry for this length of time, with no risk ofdamage.When the machine is refilled with fluid, the user must reset the Flu Out errorby entering the Pri menu and choosing ‘ y’, followed by the enter key. Thiswill clear the error and prime the fluid system ready for use. The primefunction will run the pump at maximum for 10 seconds, but only if themachine is at operating temperature.Haze outlet4Air-guideadjustmentwww.sxsevents.co.ukRemember that the type of fluid used will play a large part in determining theresulting effect. The list of fluids inside the front cover of this handbookshows the main fluids compatible with this machine. Choose a fluid suitablefor the venue and type of effect you want to create. Generally, use thestandard Haze fluid, but for longer lasting effects, contact a distributor foradvice on using another fluid grade.Changing the fluid type may also require the operating temperature of themachine to be altered to suit the new fluid. This can be done from the displayunit by using the Hot menu, and selecting from the options Hi, Lo and Nor.See the inside front cover for the correct setting for the type of fluid in use.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!