11.07.2015 Views

DGHDP Issue 1 (6.1 mb, PDF) - Healthdesign.com.au

DGHDP Issue 1 (6.1 mb, PDF) - Healthdesign.com.au

DGHDP Issue 1 (6.1 mb, PDF) - Healthdesign.com.au

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Part B - Health Facility Briefing and Planninglong hours with the neonate. This space may be separate from the NICU/SCN, but must be in <strong>com</strong>munication with the NICU/ SCN.390 .6.00390 .7.00Physicians' sleeping facilities, with access to a toilet and shower shall beprovided. If not contained within the NICU / SCN itself, the area shall have atelephone or inter<strong>com</strong> connection to the patient care area.PATIENT TREATMENT AREASEach patient treatment area in the NICU is to be 12 m2 and the SCU is to be10 m2 excluding sink and aisles. There shall be circulation adjacent to eachcot bay.Resuscitation Bay / Treatment Area as per NICU Patient Treatment area is tobe included in the SCN.A clinical handbasin is to be provided for every two NICU beds and every fourSCN beds.390 .8.00SUPPORT AREASA Respiratory Therapy Work Area and Storage Room shall be provided asrequired by the Operational Policy.390 .9.00Functional RelationshipsThe Intensive Care - Neonatal/ Special Care Nursery should be a distinct Unitlocated with ready access to the Obstertic Unit, Operating Unit, MaternityInpatient Unit and Pathology Unit. There shall be no traffic to other Unitsthrough this Unit.There should be efficient and controlled access to the NICU / SCN from theLabour and Delivery Area, the Emergency Unit, or other referral entry points.DESIGN390 .10.00390 .11.00390 .12.00390 .13.00DoorsAt least one door to each room in the NICU/ SCN must be large enough toac<strong>com</strong>modate portable X-ray equipment. Both width and height must beconsidered.Environmental ConsiderationsACOUSTICSIn the interest of noise control, sound attenuation shall be a design factor.Infection ControlISOLATION ROOM/SAn Isolation Room (type N) is required in the NICU. The room shall beenclosed and separated from the Nursery Unit with provisions for observationof the infant from adjacent nurseries or control area/s.LightingProvisions shall be made for indirect lighting and high-intensity lighting in allnurseries.DHSThe Department of Human Services, VictoriaDesign guidelines for hospitals and day procedure centres02-Nov-04<strong>Issue</strong> 1Page 227 of 426

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!