Model 70523Fault - LogicTroubleshootingThis fault - logic troubleshooting guide is adiagnostic aid in locating pump problems.Match the pump systems with the problemstatements and follow the action steps shown in thebox diagrams. This will give expedient aid incorrecting minor problems eliminating unnecessarymachine down time.Following the fault - logic diagrams are diagramaction comments of the action steps shown in thediagrams. Where applicable, the comment number ofthe statement appears in the action block of thediagrams.Recommended Gauge LocationsLoad Sensing PortTee in Line to CheckLoad Sensing PressureExplanatoryDiagramCommentNumberDecisionSolutionSymptom:1Inspect?DefectiveRepairorReplaceActionStepInstall an in lineTest Port for:System Pressureand Inlet VacuumDrain PortTee in Line to CheckCase PressureGauges RecommendedInlet vacuum gauge: 2 bar to 1 bar [30 PSI to 30 inHg]System pressure gauge: 700 bar [10,000 PSI]Case pressure gauge: 0 to 25 bar [0 to 300 PSI]17