<strong>New</strong><strong>Configurable</strong> <strong>Kelvin</strong><strong>Contactor</strong>LEADED ROL 200K (<strong>Kelvin</strong>) SERIES CONTACTORFor QFP, SO, SOT, and Other Leaded-Style ApplicationsUltimate Performance. <strong>Configurable</strong> Design.The <strong>Johnstech</strong> Leaded ROL 200K Series configurable <strong>Contactor</strong> is theultimate high performance engineering and production <strong>Kelvin</strong> solution. Idealfor high power and precision analog devices that require very tight test guardbands,this <strong>Kelvin</strong> solution delivers unprecedented mechanical and electricalperformance, flexibility and value.Solid Force Contact and Dual Touch Sense DesignThe Leaded ROL200K guarantees a perfect,high current, low resistance connection everytime. Its design is a unique combination of ourtraditional high current solid Leaded ROL 200Contact (the Force) and a dual touch, flexibleSense Contact that surrounds the Force onboth sides. This design ensures a good <strong>Kelvin</strong>connection regardless of device variations.Self Cleaning Wipe ActionTwo self cleaning features ensure that the Leaded ROL200K deliversthe lowest and most repeatable <strong>Kelvin</strong> contact resistance available on themarket today. The Force Contacts include the oxide removal wipe action of<strong>Johnstech</strong>’s patented ROL technology, which automatically prevents surfacedebris build-up on the Contact tip. In addition, the Force and Sense work incombination to remove debris between the two Contacts. These inherent wipefunctions provide long Mean Time Between Assists (MTBA) and Contact life,lowering the overall cost of test.Field <strong>Configurable</strong> DesignWith its unique configurable feature, the Leaded ROL200K <strong>Kelvin</strong> <strong>Contactor</strong>lowers overall acquisition cost and provides the ultimate in customer flexibilityand operating value. The “<strong>Kelvin</strong> Ready” design allows you to configureand reconfigure your <strong>Contactor</strong> for standard contacting, “Selective <strong>Kelvin</strong>”or full <strong>Kelvin</strong> testing. Parts can be tested with both <strong>Kelvin</strong> and non <strong>Kelvin</strong>requirements.Why <strong>Kelvin</strong>?<strong>Kelvin</strong> measurements are theultimate connection for low level,low frequency measurements. In thefour-wire <strong>Kelvin</strong> bridge configuration(shown below), a current source isapplied with one pair of wires (Force),while the voltage is measured acrossthe DUT with the other two (Sense).By separating the Force and Sensecircuits, the current flowing throughthe Sense leads becomes negligible.As a result, the voltage accuracyis only limited by the internalimpedance of the voltmeter (typically10 to 100 MΩ). This gives an inherentvoltage accuracy of parts per million.RloadRcontactSense HISense LOForce HIForce LORcontactYour Contact For High Performance.


LEADED ROL 200K SPECIFICATIONS-10Electrical Specifications Matte Tin Configuration NiPdAu ConfigurationNon-<strong>Kelvin</strong> (<strong>Kelvin</strong> with Sense)Electrical Length 1.98 mm 2.00 mmInductance: Self: 0.46 nH (3.09nH) Self: 0.46 nH (3.26nH)Mutual: 0.04 nH (0.49nH)Mutual: 0.03 nH (0.49nH)Capacitance: Ground: 0.10 pF (0.38pF) Ground: 0.10 pF (0.38pF)S 21Insertion Loss/Bandwidth(GSG):S 11Return Loss/Bandwidth(GSG):S 41Crosstalk/Bandwidth(GSSG):Average Contact DCResistance:Mutual: 0.02 pF (0.06pF)-1dB @ 23.3 GHz (1.8GHz)-20dB @ 8.2 GHz (0.8GHz)-20dB @ 34.7 GHz (5.0GHz)60 mΩ 30 mΩMutual: 0.02 pF (0.06pF)-1dB @ 23.1 GHz (2.4GHz)-20dB @ 9.4 GHz (0.6GHz)-20dB @ 29.9 GHz (6.4GHz)Current Carrying Capability: 2.75A Force (1.25 A Sense) 3.55 A Force (1.25 A Sense)Current Leakage:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!