data sheet NanoLC-Ultra™ system - Eksigent

data sheet NanoLC-Ultra™ system - Eksigent

data sheet NanoLC-Ultra™ system - Eksigent

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

traptrapFlexible <strong>system</strong> configurations for proteomicsCurrently, four configurations of the <strong>NanoLC</strong>-Ultra <strong>system</strong> areavailable for proteomics researchers:• <strong>NanoLC</strong>-Ultra 1D,• <strong>NanoLC</strong>-Ultra 1Dplus,• <strong>NanoLC</strong>-Ultra 2D,• and <strong>NanoLC</strong>-Ultra 2Dplus.The <strong>NanoLC</strong>-Ultra 1D <strong>system</strong> contains one binary gradientpump, allowing for direct on-column injections. The <strong>NanoLC</strong>-Ultra 1Dplus <strong>system</strong> adds an isocratic loading pump for sampleenrichment experiments in which sample is loaded onto a trapcolumn prior to analysis on a <strong>NanoLC</strong> column.<strong>NanoLC</strong>-Ultra 2D <strong>system</strong>s include all of the features of the1D, plus the added capability of automated 2-dimensionalchromatography. The <strong>NanoLC</strong>-Ultra 2D (two gradients) <strong>system</strong>and <strong>NanoLC</strong>-Ultra 2Dplus <strong>system</strong> (two gradients and oneisocratic loading pump) are designed for advanced applicationssuch as on-line 2D LC (see Figure 5) or high throughput setupsusing two nanoLC columns.All <strong>NanoLC</strong>-Ultra 2D and 2Dplus <strong>system</strong>s are available withone or two built-in 10-port valves. <strong>NanoLC</strong>-Ultra 2D and2Dplus <strong>system</strong> can be configured to run in either 2-dimensionalseparation mode or as two parallel, completely independentbinary gradient HPLC <strong>system</strong>s.AS-2 autosamplerThe new AS-2 Autosampler stacks together with the <strong>NanoLC</strong>-Ultra and both are operated by our <strong>Eksigent</strong> Control Softwareor through integration with the MS software. The flexible andeasy-to-use autosampler employs a 2.4 ul volume needle forinjection of small volumes without sample losses. The needleis coated with a proprietary inert coating on both the insideand outside to prevent sample losses due to adsorption.The sample compartment is completely enclosed to ensuretemperature control down to 4°C. Capacity is two microtiterplates or 96 vials. Using two different wash positions, theneedle is washed inside and outside to reduce carry-over.The 6-port injection valve has port-to-port volumes of

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!