FD 260-10 Feeder for FD 260 Tabber - Formax
FD 260-10 Feeder for FD 260 Tabber - Formax
FD 260-10 Feeder for FD 260 Tabber - Formax
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3. Pull the FUSE DRAWER out of the POWERENTRY CASING. The LINE FUSES are inside.4. Determine the proper fuse value as well as thecondition of the LINE FUSE. The fuse value isshown on the metal tip of the LINE FUSE. Thechart below lists the selected voltage in the leftcolumn followed by the proper fuse value in theright column.Selected Voltage Line Fuse Value<strong>10</strong>0V…………………….1.0A (250V time delay)120V…………………….1.0A (250V time delay)220V…………………….0.5A (250V time delay)240V (or 230V)…………0.5A (250V time delay)5. Replace the LINE FUSE if necessary. Both LINEFUSES must be intact <strong>for</strong> the <strong>FD</strong> <strong>260</strong>-<strong>10</strong> tooperate properly.6. Install the FUSE DRAWER in the POWERENTRY CASING.POWER ENTRYCASINGFUSEVOLTAGESELECTORFUSE DRAWERVOLTAGESELECTORWINDOWAPPLIANCE INLETPOWER CORDFUSE DRAWERLOCKING TABFigure 6.1 -- <strong>FD</strong> <strong>260</strong>-<strong>10</strong> Power Connection20