11.07.2015 Views

technical data & service manual split system air conditioner - Package

technical data & service manual split system air conditioner - Package

technical data & service manual split system air conditioner - Package

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AW726HL AW726CL AW726HLF AW726CLFController PCBPart No.ControlsControl circuit fuseJumper setting JP1..JP5Remote Control UnitFan & Fan MotorTypeQ'ty ……. Dia. and lenghtFan motor model…Q'tyNo. Of poles…rpm (230 V, Hi)Nominal outputCoil resistance (Ambient temp. 20 °C )mmWΩSafety devicesTypeOperating temp. Open °CCloseRun capacitor µFVACSAC ON-OFF IDUMicroprocessor250 V - 3,15 A2,54mm-5pcsSAC W-REMCross - flow1…. Ø 95 / L 617KFV4Q-11H5P-S…14…116010BRN-WHT: 561,8VLT-WHT: 197,4VLT-ORG: 63,4YEL-ORG: 155,7YEL-PNK: 115,9internal fuse145 ± 5-1440Flap MotorTypeModelRatingCoil resistance (Ambient temp. 25 °C )Heat Exch. CoilCoilRowsFin pitchFace areaΩmmStepping motorMP24GA1DC 12 V380 ± 7%Aluminium plate fin / Copper tube21,40,130DATA SUBJECT TO CHANGE WITHOUT NOTICE8