11.07.2015 Views

CT Manual 1-up - Columbia Boiler

CT Manual 1-up - Columbia Boiler

CT Manual 1-up - Columbia Boiler

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DESCRIPTION OF BOILER COMPONENTSRefer to the drawings in this manual for the location of the following listed components.See Table of Contents for location of applicable drawing and/or specification sheet.PANEL BOX WITH WARRICK SERIES 3K ELE<strong>CT</strong>RODE FITTINGThe standard control circuit for the <strong>CT</strong> Series <strong>Boiler</strong>s consists of probe type, primary andsecondary low water cut off and pump controls enclosed in a panel box; and typical operatingand safety limit pressure controls. The standard water column consists of the WarrickSeries 3K Electrode fitting which houses the three probes used for the primary low watercut off and pump control, the Honeywell L404A Operating Pressure control, the HoneywellL404C Safety Limit Pressure Control, and a 0-300 psi pressure gauge.DESCRIPTION OF PANEL BOX COMPONENTSWarrick Series DF (Dual Function)The boiler water level control consists of the Warrick Series DF (Dual Function) combinationlow water cut-off and pump control. The Series DF handles two separate level functions,one differential, and one single level, using probes and contactors. The differentialfunction uses a low probe (L) and high probe (H) to operate the pump. When the waterlevel in the boiler drops below the level of the low probe, the normally closed contact isenergized, which in turn s<strong>up</strong>plies power to the pump motor contactor/starter, causing thepump to feed water to the boiler. The “PUMP ON” light will also come on. As the pumpraises the level in the boiler and the water makes contact with the high probe, the contactoris de-energized, breaking the circuit, stopping the pump and turning off the “PUMPON” light.If the pump or water s<strong>up</strong>ply should fail, and the water level in the boiler continues to fallbelow the Low Level Cut Off (LLCO) probe, the second contactor de-energizes the normallyclosed contact, shutting off power to the burner, and energizes the normally open contact,turning on the “LOW WATER” light and/or an optional low water alarm bell.The three probe lengths in the Series 3K are:A - High Probe - 8.0"B - Low probe - 9.5"C - LLCO Probe - 11.0"The Warrick Series DF Control will reset automatically after a Low Water Cut Off. If preferred,a normally closed, <strong>Manual</strong> Reset push button is available as an option.Electrical contact ratings for the Warrick Series DF Control are 10 amps at 120 volts.Motor contactor or StarterA Motor contactor or Starter is provided to take the high amperage electrical load off theFM-148 COLUMBIA BOILER COMPANY, REV 6-06- 20 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!