Frame AdapterCHALLENGESOLUTIONPrevent oil leaks between theframe adapter <strong>and</strong> the oil sealCause:• The small air spaces between the adapter <strong>and</strong>the oil seal can allow oil to leakFill the air spaces by applying a Loctite ® 243 or 248 MediumStrength Threadlocker to the outside diameter of the oil lip seal• A Loctite ® Medium Strength Threadlocker allows the oil seal to be easily removed with a screwdriver duringthe next overhaulSteps:1. Clean the outside diameter of the oil seal <strong>and</strong> the inside diameter of the frame adapter withLoctite ® 7063 Cleaner & Degreaser2. Apply Loctite ® Medium Strength Threadlocker to the outside diameter of the oil seal3. Wipe off any excess <strong>and</strong> press into the adapter using normal techniques <strong>and</strong> toolsRESULTS• Elimination of leaks along with associated clean up <strong>and</strong> hazards.• Less oil consumption• Reduced risk of running low on lubricant.• Ease of pump service• Elimination of leaks, contamination, <strong>and</strong> corrosion due to aunitized assembly18 19