Frame AdapterCHALLENGESOLUTIONPrevent dowel pins fromseizing to the bearing frame<strong>and</strong> frame adapterCause:• The dowel pins are exposed to the exterior pump environment <strong>and</strong> if notprotected can rust <strong>and</strong> seize themselves to the bearing frame. When thesepins seize in the bearing frame the disassembly becomes very difficultBefore assembly, apply Loctite ® 8023 Marine Grade Anti-Seizeto the dowel pins• Loctite ® 8023 Marine Grade Anti-Seize Compound provides a protective coating to parts that are exposed tosevere heat <strong>and</strong> moistureSteps:1. Clean the parts2. Apply Loctite ® 8023 Marine Grade Anti-Seize to the pins3. Assemble adapter to the bearing frameRESULTS• Prevention of rust <strong>and</strong> seizure of these closefitting parts• The bearing frame <strong>and</strong> frame adapter will beeasier to separate during the next disassembly20 21