11.07.2015 Views

Extreme Networks Consolidated "i" Series Hardware Installation Guide

Extreme Networks Consolidated "i" Series Hardware Installation Guide

Extreme Networks Consolidated "i" Series Hardware Installation Guide

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Meeting Site RequirementsNOTENote that automatic shutdown is based solely on the power supply temperature sensor and is not basedon the temperature sensor of the MSM. The power supply temperature sensor readings are not visiblethrough the <strong>Extreme</strong>Ware command set. This protection is designed to prevent thermal runawayconditions, and does not ensure the protection of the system modules. Internal temperatures above55° C (+/- 5° C) can produce a decline in the long-term reliability of the system overall.The system will recover automatically once the temperature has dropped to 80° C as tracked by theindependent temperature sensor within the power supply. The temperature sensor remains active whenthe system is in a shutdown state.System Alarms in an Overheating Condition. <strong>Extreme</strong> supports the following SNMP alarms toreport overheating conditions:• Over Temperature Alarm: This trap sends notification of an overheating condition, but takes noaction. The alarm threshold is fixed at 55° C; however, you can control the alarm by turning it ON orOFF.• Overheat: This is a trap sent before the system is taken offline. It indicates that the onboardtemperature sensor has reported an overheating condition. The system will shut down until the unithas cooled sufficiently. A cold start trap will be issued when the unit has come back online.You can use the <strong>Extreme</strong>Ware command set to capture temperature logs on an hourly basis. However,the traps on the system are not configurable.You can use these traps to trigger an SNMP management platform to react with an external program toperform programmed actions to remedy the situation. For example, you could shut down power byusing a remote power management device available from a third party. The actions performed dependon both the capability of the management platform and any third-party device that can be set to controlthe flow of power to the switch.Monitoring Overheating Symptoms. In general, any system reporting temperatures above 40° Cshould be closely monitored. You should take the following actions:• Use the <strong>Extreme</strong>Ware command set to enable temperature logging and monitor for any rises ordecline in temperature in the system logs.• Ensure proper environment conditions as described earlier in this section.Environmental conditions with especially poor airflow can severely impact system performance.Numerous racks to the left and right of the system being monitored can result in the system beingcooled by the exhaust of another system or influenced by the heat emitted from the adjoiningsystems. In addition, enclosed racks can prevent proper airflow. Poor environment placement of thistype can typically result in as much as a 10° C increase to the ambient temperature (that is, thetemperature of the environment around the switch) being fed to the system.• Check airflow into and out of the system, ensuring appropriate spacing for proper air circulation.• Verify that any additional equipment installation has not blocked airflow.• Check fans to ensure that there has not been a slowdown or failure of fan operation.• Ensure that proper blank faceplates are used for all open slots.Openings in a chassis can result in air eddies in the system, resulting in regions of the systemoperating at higher temperatures.<strong>Extreme</strong> <strong>Networks</strong> <strong>Consolidated</strong> "e" and "i" <strong>Series</strong> <strong>Hardware</strong> <strong>Installation</strong> <strong>Guide</strong> 37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!