Regloplas- Temperature Control Technology
Regloplas- Temperature Control Technology
Regloplas- Temperature Control Technology
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Interconnecting system(insulating channels)Max. operating temperature 300 °C.Max. pressure 16 bar.Item Description Order No.1 Channel with 4 tubes, L = 1 mChannel with 4 tubes, L = 2 mChannel with 4 tubes, L = 2.5 m480-080635480-080636480-0806372 Elbow 480-03916233aAdapter M 30/24° – M 18/60°for connections of channel to hoseM 26 x 1.5Adapter M 30/24° – M 18/60°for connection of channel to hoseM 18 x 1.5301-080809301-0808164 Angled coupling W 22-PLfor inter-connection of channel5 Angled coupling, EVW 22-PLfor connection of channel to hose305-068107305-0681206 Straight coupling G 22-PL 305-0680357 Hose M 26 x 1.5 bzw. M 18 x 1.5 Page 26,item 2 – 4Advantages– Reduction of heat losses over long distancesbetween consumer and temperature controlunit.– Increased safety: Tubes are sturdier thanhose lines.– Savings in time and costs: Instead of buildingthe installation yourself, a complete connectionsystem including screw couplings,hoses, etc. is at your disposal.RemarksFor safety reasons and in order to compensatefor expansion due to heat, we recommendusing heat-insulated all-metal flexible tubesfor high temperatures between temperaturecontrol unit, insulating channel and insulatingchannel-consumer.Depending on the temperature, suitable heatinsulatedplastic tubes can also be used.Further accessories on request28