11.07.2015 Views

Regloplas- Temperature Control Technology

Regloplas- Temperature Control Technology

Regloplas- Temperature Control Technology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Standard equipmentElectrical section• RT100 or RT61 control system ➔ Optimal fitfor practically every application.• Electric control in accordance with IECstandards. Tropic-proof up to 90% humidity.Completely separated from the pumpingsection and protected against direct contact➔ Safe operation.Mechanical section• Operating temperature independent ofcooling water pressure ➔ Flexible operation.• All components exposed to water are madeof non-ferrous materials. Tank made of stainlesssteel ➔ Long service life.• Heating elements made of heat-resistantalloy Incoloy® for high corrosion resistance➔ Safe operation, long service life.• Sturdy and powerful centrifugal pump highcapacity ➔ Quick compensation of disturbances,good regulating performance.• Filter in cooling water inlet.• Low-scale, dual-circuit cooling system‘SK/2SK’ ➔ Significant reduction of scaling inthe cooler (not available for the P140smart).• Automatic water refill.• Leak-free Pump (except SG85).Safety• Safety valve ➔ Prevents excessivepressure in the unit.• Pressure gauge for system pressure.• Safety thermostat ➔ Protection againstoverheating.• Automatic fluid level control➔ Protection against running dry.• Acoustic common alarm.P100SP100MP140smartP160SP160M(D)P161XLP180SP180M(D)Quality assurance: At <strong>Regloplas</strong>, all units, whether standard orcustomised, undergo all phases of rigorous final testing.Unit-specific equipmentEquipment P100S P100M P140smart P160S P160M(D) P161XL P180S P180M(D)<strong>Control</strong> system RT100 (options see page 17) • • – • • • • •<strong>Control</strong> system RT61 (options see page 17) – – • – – – – –Solid-state Relay (SSR) instead of heating contactor • • • • • • • •Electronic flow measurement ᐤ ᐤ ᐤ ᐤ ᐤ ᐤ ᐤ ᐤManual shut-off valve in the inlet and outlet ᐤ ᐤ – ᐤ ᐤ • ᐤ ᐤInlet filter • • ᐤ • • • • •Display of outlet pressure on RT100 ᐤ ᐤ – • • • • •Drainage of the fluid from the consumer by suction ᐤ ᐤ ᐤ • • – • •Patented low-scale cooling system «SK» – – – • • • • •Unit in IP54 protection degree • • – • • • • •• Standard equipment°Option – Not available Further options available upon request9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!