4. Trouble ShootingIf the <strong>UPS</strong> system does not operate correctly, please solve the problem by using the table below.Symptom Possible cause RemedyNo indication and alarm in the frontdisplay panel even though the mains isnormal.The iconand the warning codeflash on LCD display and alarmbeeps every second.The icon and flash onLCD display and alarm beeps everysecond.The icon and flash onLCD display and alarm beeps twiceevery second.Fault code is shown as 43. The iconlights on LCD display andalarm beeps continuously.Fault code is shown as 14, 15, or 17.The iconlights on LCDdisplay, and alarm beeps continuously.Other fault codes are shown on LCDdisplay and alarm beeps continuously.Battery backup time is shorter thannominal valueThe icon and flash on LCDdisplay and alarm beeps every second.The AC input power is notconnected well.EPO function is enabled andEPO switch is in “OFF” status,or the jumper is open.The external or internalbattery is incorrectlyconnected.<strong>UPS</strong> is overload.<strong>UPS</strong> is overloaded. Devicesconnected to the <strong>UPS</strong> are feddirectly by the electricalnetwork via the Bypass.After repetitive overloads, the<strong>UPS</strong> is locked in the Bypassmode. Connected devices arefed directly by the mains.<strong>UPS</strong> is overload too long andbecomes fault. Then <strong>UPS</strong> shutdown automatically.The <strong>UPS</strong> shut downautomatically because shortcircuit occurs on the <strong>UPS</strong>output.A <strong>UPS</strong> internal fault hasoccurred.Batteries are not fully chargedBatteries defectFan is locked or not working;or the <strong>UPS</strong> temperature is toohigh.Check if input cable firmlyconnected to the mains.Set the circuit in closedposition to disable EPOfunction.Check if all batteries areconnected well.Remove excess loads from <strong>UPS</strong>output.Remove excess loads from <strong>UPS</strong>output.Remove excess loads from <strong>UPS</strong>output first. Then shut downthe <strong>UPS</strong> and restart it.Remove excess loads from <strong>UPS</strong>output and restart it.Check output wiring and ifconnected devices are in shortcircuit status.Contact your dealerCharge the batteries for atleast 7 hours and then checkcapacity. If the problem stillpersists, consult your dealer.Contact your dealer to replacethe battery.Check fans and notify dealer.24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!