Technical description 07/2010 Kollmorgen<br />

6.9.8 Functional description<br />

In case of use of the STO function the input STO-Enable must be connected to the exit of<br />

a security control or a safety relay, which meets at least to therequirements of the SIL<br />

CL2 according to IEC 62061 and PL d according to ISO 13849-1 (see the connection diagram<br />

on page 40).<br />

Possible states of the servo amplifier in connection with STO function:<br />

STO-ENABLE ENABLE Display Motor has torque SIL CL2 / PL d<br />

0 V 0 V -S- no yes<br />

0 V +24 V F27 no yes<br />

+24 V 0 V normal status e.g. 06 no no<br />

+24 V +24 V<br />

normal status e.g.<br />

E06<br />

yes no<br />

When STO function is engaged during operation by separating input STO-Enable<br />

from 24 VDC, the motor runs down out of control and the servo amplifier displays<br />

the error F27. There is no possibility of braking the drive controlled. If a controlled<br />

braking before the use of the restart lock is necessary, the drive must be braked<br />

and the input STO-ENABLE has to be separated from +24 VDC time-delayed.<br />

Because restart lock is a single-channel system, erroneous engaging will not be<br />

recognized. Therefore the output of the control must be supervised for possible<br />

malfunction.<br />

If the STO function is not needed in the application, then the input STO-ENABLE<br />

must be connected directly with +24VDC. The STO function is passed by now and<br />

cannot be used. The servo amplifier cannot be used as a safety component<br />

referring to the EC Machine Directive now.<br />

When wiring the input STO-ENABLE within one enclosure it must be paid attention to the<br />

fact that the used cables and the enclosure meet the requirements of IEC 60204-1.<br />

If the wiring leads outside the demanded enclosure, the cables must be laid durably<br />

(firmly), and protected from outside damage (see chapter "Wiring").<br />