11.07.2015 Views

Beamtower ING - Tecnoalarm

Beamtower ING - Tecnoalarm

Beamtower ING - Tecnoalarm

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

AnalysisTemperatureTemperature loggerThe <strong>Beamtower</strong> barrier is equipped with a logger which constantlyregisters the temperature inside the column and shows itgraphically. The logger records the data of the last 23 hours offunctioning, the activity of the heaters with indication of date andtime, and a possible disqualification of the individual beams or theentire barrier.The temperature logger is also a measuring instrument whichpermits assessment of the barrier’s functioning according to theclimatic conditions.Data FileEventsEvent logThe event log contains the events relating to the barrier, i.e. thealarms, the diagnostics and the changes in state.A maximum of 128 events are recorded in reverse chronologicalorder, with indication of date and time, in the memory of themodule or the control panel the barrier is connected to. The eventsalways show the status of all of the barrier’s beams, i.e. presence,interruption, masking, disqualification and disabling, identifyingeach beam with a number. The event log also lists the tamperalarms, anti-climb-over alarms, the intervention of the heatermodules as well as power supply signaling for each individualcolumn (TX and RX).Serial DataAnalysisCommunication analysisThe serial communication both between the columns and betweenthe barrier and the control panel or the module is constantlymonitored, and so is the exactness and coherence of the sent data.A counter records all of the communication transactions, whereasa second counter totalizes the possible communication errors.The communication analysis allows us to determine the amountof communication errors caused by electrical disturbances or bythe deterioration of the serial bus, confronting the counters andclassifying the errors as insignificant, not critical or dangerous.AlignmentMonitorAlignmentThe alignment of the beams is constantly monitored. For eachbeam both the reference alignment value, i.e. the average samplevalue, and the temporary alignment value are viewed. The beam’soptical alignment levels are viewed graphically on a three-levelscale: minimum, good and insufficient. The window also shows theprogrammed beam power for the beam in question.


Open perimeter modeClosed perimeter mode


<strong>Beamtower</strong>General principles and characteristicsAnti-climb-over and antiopening protectionThe top cap of the column contains an antitamper board withantiopening and anti-climb-over protection.ControllerThe controller is the heart of the column and allits electronic components are connected to it. Thecontroller of the receiver column is connectedto the control panel or to the module and, forsynchronization, to the corresponding controllerof the transmitter column. The connectionsbetween the columns and the control panel aremade through two different RS485 serial busses.Battery bayEach column is equipped with a bay for one12V/7Ah battery.Front coverThe front cover of the <strong>Beamtower</strong> barriers consist inremovable polycarbonate modules which are insertedone on top of the other. In this way, access to theelectronic components is comfortable both during theinstallation and maintenance.


Orientation of the optical systemMODBEAM modulesThe MODBEAM are the optical system ofthe barrier, we distinguish: transmissionand reception modules. Each module emits2 beams, each of them being composed oftwo parallel rays. The interruption of thebeam is detected by analyzing the cuttingof the rays it is composed of: a techniquewhich increases significantly the immunityagainst false alarms. The beams can beprogrammed independently. For eachof them it is possible to program oneof the numerous detection modes. Thedetection modes analyze: the number ofsimultaneously interrupted beams in adetermined period of time, the interruptiontime and the position of the beam inside thecolumn.OrientationThe lenses of the MODBEAM modules can beturned individually on the horizontal and verticalaxis. The alignment of the beams is made with thehelp of two precision control knobs permitting amillimetric adjustment.The +/-90° horizontal orientation of the beamspermits the installation of the column in perimeterconfigurations with 180 degrees orientationof the beams. The +/-10° vertical orientationof the beams permits the compensation ofdifferences of levels if the columns are installedon craggy ground. According to the distance, thecompensation varies from 1.7 to 10.5 meters.AlignmentHeaterEach column can be equipped,depending on the model, with amaximum of two heater modules whichcompensate the temperature insidethe column in case it is particularlylow (anti-freeze protection). Thethermostatic control of the heaters isguaranteed by the controller.1 3The alignment of the barriers is a three-stageprocedure:1 Stage 1: preliminary alignmentwith optical viewfinder2 Stage 2: alignment with buzzer and handheldMONITOR 868 wireless receiver3 Stage 3: fine-tuning alignment with shutterFastening baseThe steel plate for floor mounting is equipped withreinforcing ribs and a special anti-corrosive coating andcan be fixed directly to a solid surface or a concrete plinth.2MONITOR 868


TECHNICAL SPECIFICATIONS BEAMTOWER/4 BEAMTOWER/6 BEAMTOWER/8 BEAMTOWER/8 3MColumn height H 1425mm H 1970mm H 2515 mm H 3060 mmColumn dimensionsFixingMaximum rangeInstallation configurations(L x P) 153 x 178mmWall mounting or floor mounting with optional fastening base100mBarrier – Closed perimeter (3 configurations) – Open perimeter (6 configurations)Number of beams 4 6 8 8Orientation of beams Horizontal 180° (+/- 90°) - Vertical 20° (+/- 10°)Emission powerSynchronizationOperating voltageRated voltageMains supplyBatteryBeam interruption timeDetection modeAntimasking controlDisqualificationTamperProgrammable on 5 levelsDigital automatic10.5V ... 14.5V DC13V DCWith optional 28V AC transformerBay for one 12V/7Ah batteryEach beam programmable individually with 4 valuesProgrammable with 16 modesProgrammable with 3 valuesProgrammable with the number of beams and the duration of the conditionAntiopening protection (2 micro switch) – Anti-climb-over protection (6 micro switch)Max. consumption RX 165mA at 13V 180mA at 13V 196mA at 13VMax. consumption TX 197mA at 13V 243mA at 13V 288mA at 13VMax. consumption heater moduleOperating temperatureProtection class770mA at 28V (bay for max. 2 heater modules, depending on the model)-25°C ... +55°CIP45 (retrofitting possible)Compatibility: the <strong>Beamtower</strong> barriers are compatible with the <strong>Tecnoalarm</strong> TP8-64 BUS, TP16-256, TP8-96 and TP16-512 GSM control panelsACCESSORIESFastening baseHeater moduleTransformerMONITOR 868Floor mounting fastening base – dimensions (L x H x D): 400 x 400 x 23mmThermostat and heater moduleTransformer kitWireless receiver for alignmentVia Ciriè, 38 - 10099 San Mauro T.se - Torino (Italy)tel. +390112235410 - fax +390112735590tecnoalarm@tecnoalarm.comwww.tecnoalarm.com495, Rue Antoine Pinay - 69740 Genas - Lyon (France)tél. +33478406525 - fax +33478406746tecnoalarm.france@tecnoalarm.com - www.tecnoalarm.comAgence de Paris: 125, Rue Louis Roche - 92230 Gennevilliersc/Vapor 18 (Pol. Ind. El Regas)08850 Gavá - Barcelona (España)tel. +34936622417tecnoalarm@tecnoalarm.es - www.tecnoalarm.es

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!