11.07.2015 Views

Cable

Cable

Cable

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Flexible Rubber Power (All Applications)0.6/1kV 110°CEZseriesNUMBER OF CONDUCTOR OVERALL MINIMUM APPROX. CURRENTCONDUCTORS (c) DIAMETER DIAMETER BENDING WEIGHT RATING*X CROSS SECTION (mm) (mm) RADIUS (kg/km) (Amps)AREA (mm 2 ) Nominal (mm)2c 1.5 1.50 9.1 36 83 282c 2.5 2.10 10.8 43 120 392c 4.0 2.50 11.8 47 161 512c 6.0 3.10 13.3 53 217 652c 10.0 4.10 17.6 70 378 892c 16.0 5.10 20.5 82 538 1202c 25.0 6.40 24.3 97 800 1602c 35.0 7.80 27.7 111 1071 1953c 1.5 1.50 9.8 39 104 243c 2.5 2.10 11.3 45 148 333c 4.0 2.50 12.4 50 203 443c 6.0 3.10 14.2 57 281 563c 10.0 4.10 18.7 75 486 763c 16.0 5.10 21.8 87 696 1003c 25.0 6.40 26.0 104 1051 1353c 35.0 7.80 29.6 118 1414 1653c 50.0 9.20 33.3 133 1942 2003c 70.0 10.80 38.0 152 2607 2553c 95.0 12.80 43.4 173 3490 3153c 120.0 14.50 48.3 193 4324 3653c 150.0 16.30 54.1 216 5403 4153c 185.0 18.00 59.6 239 6647 4803c 240.0 20.30 66.3 265 8466 5703c 300.0 23.00 73.9 296 10476 6504c 1.5 1.50 10.7 43 129 244c 2.5 2.10 12.4 50 185 334c 4.0 2.50 13.8 55 258 444c 6.0 3.10 15.8 63 358 564c 10.0 4.10 20.5 82 613 764c 16.0 5.10 23.9 96 880 1004c 25.0 6.40 28.5 114 1333 1354c 35.0 7.80 32.5 130 1795 1654c 50.0 9.20 36.8 147 2486 2004c 70.0 10.80 42.2 169 3351 2554c 95.0 12.80 48.0 192 4485 3154c 120.0 14.50 53.6 215 5567 3654c 150.0 16.30 60.2 241 6965 4154c 185.0 18.00 66.3 265 8562 4804c 240.0 20.30 73.8 295 10927 5704c 300.0 23.00 82.2 329 13504 6504c 400.0 26.00 92.2 369 17647 7505c 1.5 1.50 11.8 47 157 245c 2.5 2.10 13.9 56 229 335c 4.0 2.50 15.3 61 315 445c 6.0 3.10 17.4 70 436 565c 10.0 4.10 22.6 90 750 765c 16.0 5.10 26.4 105 1077 1005c 25.0 6.40 31.7 127 1641 1355c 35.0 7.80 36.3 145 2221 1655c 50.0 9.20 41.1 164 3074 2005c 70.0 10.80 47.0 188 4139 2555c 95.0 12.80 53.7 215 5552 3155c 120.0 14.50 60.1 240 6901 3655c 150.0 16.30 67.3 269 8622 4155c 185.0 18.00 74.2 297 10613 4805c 240.0 20.30 82.7 331 13555 570*AS/NZS 3008, Table 11/14 (Fixed – Unenclosed touching) 110°C operating temperature, 40°C ambient temperature, 25°C ambient soil temperature. For Current Ratings based on other installation methods,refer to the table on Page 54/55 of this catalogue. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle <strong>Cable</strong>s is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.issue 13.1 Triangle Flexible <strong>Cable</strong>s9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!