11.07.2015 Views

Cable

Cable

Cable

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

XUseriesFlexible Rubber VSD/VFD Drive <strong>Cable</strong>0.6/1kV 90°C(Split Earth 10mm 2 and above)TYPICAL APPLICATIONSVariable Speed Drives, Variable Frequency Drives, Electric MotorsCONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinnedInsulation: LSFLEX ® XL-20 (X-90)Cross-linked, PolyethyleneSeparator: Polyethylene tapeBraid/Armour Options:Tinned Copper Wire Braid (90%)Galvanized Steel Wire Braid (90%)Sheath: LSFLEX ® R-70, Cross-linked, Thermoset,Elastomeric, Splash resistant to oil, skydrol,petrol, acid, sea water. Resists ozone and UV.Excellent abrasion resistance.OPERATING TEMP-40°C to +90°CCORE IDENTIFICATIONTo customer specificationSHEATH COLOURTo customer specificationSTANDARDSAS/NZS 1125AS/NZS 5000.13 x Split EarthPower CoresVOLTAGE RATING600/1000 VoltsNUMBER OF CONDUCTOR NOMINAL OD OVERALL MINIMUM APPROX. CURRENTCONDUCTORS (c) DIAMETER OVER DIAMETER BENDING WEIGHT RATING*X CROSS SECTION (mm) BRAID (mm) RADIUS (kg/km) (Amps)AREA (mm 2 ) (mm) Nominal (mm)3c 1.5+1.5E 1.5 9.8 13.6 82 224 193c 2.5+2.5E 2.1 11.3 15.1 90 290 263c 4.0+4.0E 2.5 12.3 16.1 96 364 353c 6.0+6.0E 3.1 13.9 17.6 106 466 453c 10+3c 1.5E 4.1 15.5 19.3 116 588 623c 16+3c 2.5E 5.1 16.8 20.5 123 795 833c 25+3c 4.0E 6.4 20.2 23.9 143 1153 1103c 35+3c 6.0E 7.8 23.1 26.9 161 1530 1353c 50+3c 10E 9.2 26.2 30.2 181 2139 1703c 70+3c 10E 10.8 30.1 34.3 206 2732 2153c 95+3c 16E 12.8 34.4 39.0 234 3669 2653c 120+3c 16E 14.5 38.5 43.3 260 4395 3053c 150+3c 25E 16.3 43.3 48.5 291 5603 3503c 185+3c 25E 18.0 47.8 53.2 319 6678 4053c 240+3c 35E 20.3 53.2 59.0 354 8561 4803c 300+3c 50E 23.0 59.4 65.7 394 10711 5503c 400+3c 50E 26.0 66.8 73.6 442 13530 630*AS/NZS 3008, Table 7 (Fixed – Unenclosed touching) 90°C operating temperature, 40°C ambient temperature, 25°C ambient soil temperature. For Current Ratings based on other installation methods,refer to the table on Page 52 of this catalogue. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle <strong>Cable</strong>s is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.issue 13.1 Triangle Flexible <strong>Cable</strong>s13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!