11.07.2015 Views

Cable

Cable

Cable

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

XNseriesFlexible Rubber Termite ResistantPower & Control for Fixed Wiring0.6/1kV 90°CTYPICAL APPLICATIONSMains and Sub-Mains, Final Sub Circuits in Termite Prone AreasCONSTRUCTIONConductor: Finely stranded annealed copperto IEC 60228 Class 5&6 & AS/NZS 1125.Available in plain or tinnedInsulation: LSFLEX ® XL-20 (X-90)Cross-linked, PolyethyleneSheath: LSFLEX ® R-70 Cross-linked, Thermoset,Elastomeric, Splash resistant to oil, skydrol,petrol, acid, sea water. Resists ozone and UV.Excellent abrasion resistance..VOLTAGE RATING600/1000 VoltsCORE IDENTIFICATIONTo customer specificationSHEATH COLOURTo customer specificationSTANDARDSAS/NZS 1125AS/NZS 5000.1Nylon: Extruded nylon protective barrierSacrificial Oversheath: LSFLEX ® S-40 (HF-110-R)Flame Retardant, Crosslinked, Thermoset,Elastomeric, Low Smoke, Zero Halogen.Splash resistant to oil, skydrol, petrol, acid,sea water. Resists ozone and UV.Excellent abrasion resistance.OPERATING TEMP-40°C to +90°CNUMBER OF CONDUCTOR NOMINAL OD OVERALL MINIMUM APPROX. CURRENTCONDUCTORS (c) DIAMETER OVER DIAMETER BENDING WEIGHT RATING*X CROSS SECTION (mm) INSULATION (mm) RADIUS (kg/km) (Amps)AREA (mm 2 ) (mm) Nominal (mm)1c 2.5 2.1 3.6 8.6 129 81 281c 4.0 2.5 4.0 9.0 136 98 371c 6.0 3.1 4.7 9.7 145 122 471c 10.0 4.1 5.7 10.7 160 172 651c 16.0 5.1 6.9 11.9 178 233 861c 25.0 6.4 8.5 13.5 203 334 1151c 35.0 7.8 9.9 14.9 224 438 1451c 50.0 9.2 11.5 16.5 247 593 1751c 70.0 10.8 13.3 18.3 275 782 2251c 95.0 12.8 15.3 20.6 308 1036 2801c 120.0 14.5 17.3 22.5 337 1268 3251c 150.0 16.3 19.5 25.0 374 1571 3751c 185.0 18.0 21.7 27.3 410 1924 4351c 240.0 20.3 24.2 30.1 451 2446 5201c 300.0 23.0 27.2 33.2 499 3004 6001c 400.0 26.0 30.7 36.9 554 3916 7001c 500.0 29.2 34.4 40.8 612 4914 8101c 630.0 32.8 38.4 45.1 676 6137 940*AS/NZS 3008, Table 7 (Fixed – Unenclosed touching) 90°C operating temperature, 40°C ambient temperature, 25°C ambient soil temperature. For Current Ratings based on other installation methods,refer to the table on Page 52 of this catalogue. Refer to Technical Information for correction factors, voltage drop, short circuit rating and other conditions.Triangle <strong>Cable</strong>s is not liable for any errors, omissions, etc., and reserves the right to modify specifications at any time.20Triangle Flexible <strong>Cable</strong>s issue 13.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!