KOLLMORGEN Version 1 -11/07 Configuration File Parameters<br />
Chapter 7<br />
Appendix B CONFIGURATION FILE PARAMETERS<br />
The motor parameters must now be changed to suit the specific motors that are<br />
to be connected to the drive controller. The parameters are:<br />
� Peak Current Level<br />
� Drive Temperature (Read <strong>On</strong>ly)<br />
� Drive Bus Voltage displayed in Volts (Read <strong>On</strong>ly)<br />
# sqNode[0] drive[0] "Kollmorgen SqDC4" "1"<br />
SQSTEPParamCURRENT_LEVEL 0.000000<br />
SQSTEPParamDRIVE_TEMP 36<br />
SQSTEPParamBUS_VOLTAGE 37.500000<br />
# sqNode[0] drive[1] "Kollmorgen SqDC4" "1"<br />
SQSTEPParamCURRENT_LEVEL 0.000000<br />
SQSTEPParamDRIVE_TEMP 36<br />
SQSTEPParamBUS_VOLTAGE 37.500000<br />
# sqNode[0] drive[2] "Kollmorgen SqDC4" "1"<br />
SQSTEPParamCURRENT_LEVEL 0.000000<br />
SQSTEPParamDRIVE_TEMP 36<br />
SQSTEPParamBUS_VOLTAGE 37.000000<br />
# sqNode[0] drive[3] "Kollmorgen SqDC4" "1"<br />
SQSTEPParamCURRENT_LEVEL 0.000000<br />
SQSTEPParamDRIVE_TEMP 36<br />
SQSTEPParamBUS_VOLTAGE 37.000000<br />
B.1 Peak Current Level<br />
Amplitude of the sine wave produced as a percentage of the drive peak rated<br />
current which is 4.5 Amps.<br />
Where X: is a value between 0 and 100 and Dlpeak=4.5<br />
SqDC SynqNet DC Drive 31