UECH <strong>210</strong>/211 CONTROLH16 - ST2 polarity Flag 0H17 - ST4 polarity Flag 0H26 – serial configuration Num 0H27 – select output mode Num 0H28 – presence of heat pump Flag 1H29 – set change to heating mode °C 0H38 – polarity … relay 3 (inversion) Flag 1H39 - offset sensor ST1 °C 0H40 - offset sensor ST2 °C 0H41 - offset sensor ST3 °C/10 - Kpa*10 0H42 - offset sensor ST4 °C 0H43 – network frequency Flag 0H44 – family protocol address Num 0H45 – device protocol address Num 0H46 – user password Num 22H47 – supervisor password Num 177H48 – Number of compressors per circuit Num 1H49 – Select pressure-temperature mode Num 3H50 – Compressor switch on sequence Num 0H51 – Polarity relay compressor 2 or partialization Num 0H52 – 0 degrees Celsius 1 Fahrenheit Num 0H53 – Enable air machines Num 0H56 – Alarm output polarity Num 0ALARM PARAMETERS (ALL)A01 - bypass low pressure from ON compressor Sec 90A02 – no. of times in an hour low pressure switch triggers Num 3A03 - bypass flow switch from pump Sec 10A04 – time flow switch is ON for ON alarm Sec 2A05 – time flow switch is OFF for OFF alarm Sec 2A06 – number of times an hour flow switch triggers Num 3A07 – bypass thermal compressor Sec 0A08 – number of times an hour thermal compressortriggers Num 3A09 – number of times an hour thermal fan triggers Num 3A10 - bypass antifreeze alarm from machine ON Min 1A11 - antifreeze alarm set °C 2A12 – antifreeze alarm hysteresis °C 3A13 – number of times an hour antifreeze alarm triggers Num 3A20 – special antifreeze: water pump activation set °C 8A21 – special antifreeze: heating mode activation set °C 5A22 – special antifreeze: set deactivation °C 12A23 – special antifreeze: enable function Flag 0A24 – enable low pressure during de-frost Flag 0A25 – set maximum adjustment temperature °C 30A26 – duration high temperature alarm ON Sec*10 120COMPRESSOR PARAMETERS (CP)C01 – compressor safety time ON OFF Sec*10 9C02 – compressor safety time ON ON Sec*10 30C03 – thermo regulator hysteresis during cooling °C 2C04 - thermo regulator hysteresis during heating °C 2C05 – Delta triggering adjustment levels °C 3C06 – interval between first-second compressor triggering Sec 5C07 – interval between first-second compressor switch off Sec 5C08 – enable accumulation compensation Flag 1C09 – set block accumulation compensation during cooling °C 3C10 - set block accumulation compensation during heating °C 45Versjon <strong>1.5</strong><strong>NO</strong> – Mai 2007 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!