UECH <strong>210</strong>/211 CONTROLF13 - % velocity… fan maximum during cooling % 100F14 - set velocity… fan maximum during cooling °C/10 - KPa*10 400F15 - % velocity… fan minimum during heating % 100F16 - % velocity… silent fan maximum during heating % 100F17 - set velocity… fan minimum during heating °C/10 - KPa*10 180F18 – fan adjustment band during heating °C/10 - KPa*10 40F19 - % velocity… fan maximum during heating % 100F20 - set velocity… fan maximum during heating °C/10 - KPa*10 120F25 – pre-ventilation time Sec 0P01 – pump operating mode Num 0P02 – compressor activation from pump activation delay Sec 60P03 – pump deactivation from compressor deactivationdelay Sec 20ANTIFREEZE/BOILER PARAMETERS (FRO)r01 - antifreeze resistance configuration Flag 0r02 - antifreeze resistance configuration during cooling Flag 1r03 - antifreeze resistance configuration during heating Flag 1r04 – antifreeze sensor selection during heating Flag 1r05 - antifreeze sensor selection during cooling Flag 1r06 – antifreeze resistance off or on stand-by Flag 1r07 – set internal antifreeze resistance during heating °C 2r08 – set internal antifreeze resistance during cooling °C 4r09 – set maximum antifreeze resistance °C 10r10 – set minimum antifreeze resistance °C 2r11 – antifreeze resistance hysteresis °C 1r12 – activate heat pump block Flag 0r13 – set ext. temp. off heat pump °C -5r14 - delta ext. temp. off heat pump °C 1r15 – Enable resistance integration Flag 0DEFROST PARAMETERS (DFR)d01 – enable defrost Flag 1d02 – defrost count starting temperature °C/10 - KPa*10 -50d03 - defrost count interval Min 30d04 – defrost stop temperature °C/10 - KPa*10 250d05 – defrost maximum temperature Min 4d06 – anti-breathing time Sec 0d07 – dripping time Sec 60d08 – start defrost count temperature °C/10 -25d09 –defrost stop temperature °C/10 400d10 – enable dynamic defrost Flag 1d11 – offset dynamic defrost °C/10 - KPa*10 -50d12 – external t set point in dynamic defrost °C 0d13 – external delta t in dynamic defrost °C -5LABEL – SeT 0LABEL - TP (SENSOR VALUES) 0LABEL - ERR(ALARMS IN PROGRESS) 0LABEL - ID(DIGITAL INPUT STATE) 0LABEL - Par(PARAMETRES) 0LABEL – PSS(PASSWORD) 0LABEL – Ohr(COUNTER) 0LABEL - COO(SET COOLING) 0LABEL - HEA(SET HEATING) 0LABEL - CnF(CONFIGURATION) 0LABEL - CP(COMPRESSOR) 0LABEL - FAN(FANS) 0LABEL - ALL(ALARMS) 0Versjon <strong>1.5</strong><strong>NO</strong> – Mai 2007 21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!