12.07.2015 Views

Prisma Plus LV Switchboards - POWERLAB

Prisma Plus LV Switchboards - POWERLAB

Prisma Plus LV Switchboards - POWERLAB

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CatalogueG SystemPack, wall mount andfloor standing enclosures<strong>Prisma</strong> <strong>Plus</strong> <strong>LV</strong> <strong>Switchboards</strong>Devised to save time


General contentsIndex 2General presentation 8System G Pack 10System G 17General presentationInstallation and connection of units in the switchboardInstallation and connection of units in the ductChoice of enclosureDistribution, connection, accessoriesDimensions 133Characteristics 1451


IndexCat. no Designation Pages Cat. no Designation Pages03196 4 M6 hexagonal spacers, H=23mm 55, 67, 117, 11903197 4 M6 hexagonal spacers, H=55mm 55, 67, 117, 11903198 4 M6 hexagonal spacers, H=25mm 55, 6703199 4 M8 hexagonal spacers, H=40+10mm 55, 6703202 Modular front plate, 2 modules 5303203 Modular front plate, 3 modules 45, 48, 52, 5303204 Modular front plate, 4 modules 4503205 Modular front plate, 5 modules 13, 45, 4803213 Modular front plate, 3 modules, W=250mm 62, 6403214 Modular front plate, 4 modules, W=250mm 6203220 Blanking strip, L=1000mm 15, 47, 12803221 4 divisible blanking plates, W=90mm 15, 47, 12803230 Front plate for horizontal fixed NS250 with toggle 3403231 Front plate for horizontal INS250 380300003001 Modular device rail 45, 48, 52, 5303002 Adjustable modular device rail 35, 37, 39, 43,45, 48, 54, 11703003 Recessed modular device rail 39, 49, 5403004 Rear modular device rail 13, 48, 49, 54,11703005 45° DIN rail support 117, 11903008 Modular device rail for NSA in Pack enclosure 1303010 Modular device rail, L=250mm 62, 64, 6603011 Adjustable modular device rail, L=250mm 59, 61, 62, 64,65, 6603030 Mounting plate for horizontal fixed NS-INS250 with 34, 38toggle03031 Mounting plate for horizontal fixed NS250 with 36rotary handle03032 Mounting plate for horizontal fixed NS250 with 34, 36, 39motor mechanism or horizontal plug-in NS250 withtoggle03033 Mounting plate for horizontal fixed Vigi NS250 with 34toggle03040 Mounting plate for vertical fixed NS250 with toggle 35, 3903041 Mounting plate for vertical fixed NS250 with rotary 37handle03043 Mounting plate for NS-INS250 source changeover 40, 41system with rotary handles03050 Mounting plate for vertical fixed NS-INS250 with 58, 60toggle, W=250mm03051 Mounting plate for vertical fixed NS-INS250 with 58rotary handle, W=250mm03070 Mounting plate for horizontal fixed NS630 with 32, 38toggle03073 Mounting plate for vertical fixed NS-INS630 with 33, 39toggle03074 Mounting plate for vertical fixed NS630 with rotary 33handle03080 Mounting plate for vertical fixed NS-INS630 with 58, 60toggle, W=250mm03081 Mounting plate for vertical fixed NS-630 with rotary 58handle, W=250mm03113 Mounting plate for INF32/40 42, 4303114 Mounting plate for INF63-160 42, 4303164 20 M4 clip-nuts for DIN rails 55, 6703165 20 M5 clip-nuts for DIN rails 55, 6703166 20 M6 clip-nuts for DIN rails 55, 6703168 Mounting plate for Tego Power 4903170 Slotted mounting plate, 4 modules, for wall-mount 54or floor-standing enclosure03171 Recessed slotted mounting plate, 4 modules, for 49, 54wall-mount or floor-standing enclosure03172 Recessed slotted mounting plate, 6 modules, for 13, 49, 54wall-mount or floor-standing enclosure03173 Recessed slotted mounting plate, 9 modules, for 54wall-mount or floor-standing enclosure03175 Slotted mounting plate, 4 modules, W=250mm 65, 6603176 Recessed slotted mounting plate, 4 modules, 66W=250mm03177 Recessed slotted mounting plate, 6 modules, 66W=250mm03178 Recessed slotted mounting plate, 9 modules, 66W=250mm03180 20 M4 clip-nuts for slotted mounting plates 55, 6703181 20 M5 clip-nuts for slotted mounting plates 55, 6703182 20 M6 clip-nuts for slotted mounting plates 55, 6703183 20 M5 self-tapping screws for functional unit 55, 67mounting03185 4 M5 hexagonal spacers, H=9mm 55, 6703186 4 M5 hexagonal spacers, H=23mm 55, 6703187 4 M5 hexagonal spacers, H=55mm 55, 6703194 20 captive nuts for M6 hexagonal spacers 55, 67, 12403195 4 M6 hexagonal spacers, H=9mm 55, 67, 117, 11903232 Front plate for horizontal fixed NS250 with rotary 36handle03233 Front plate for horizontal plug-in NS250 with toggle 3403234 Front plate for horizontal fixed NS250 with motor 36mechanism03235 Front plate for INS250 source changeover system 41with rotary handles03236 Front plate for horizontal fixed NS250 with toggle + 34ammeter03237 Front plate for horizontal fixed Vigi NS250 with 36rotary handle03238 Front plate for horizontal fixed Vigi NS250 with 34toggle03241 Front plate for 3-4 vertical Vigi NS250 devices with 35toggles03243 Front plate for 3-4 vertical NS250 devices 35, 3703244 Front plate for 3-4 vertical Vigi NS250 devices with 37rotary handles or motor mechanisms03245 Front plate for vertical NS250 source changeover 40system with rotary handles03247 Front plate for INS250 complete source41changeover assembly03248 Front plate for vertical INS250 3903249 Blanking plate for vertical NS-INS250 12803250 Front plate for vertical fixed NS250 with toggle, 58W=250mm03251 Front plate for vertical fixed INS250 with toggle, 60W=250mm03252 Front plate for vertical fixed Vigi NS250 with 58toggle, W=250mm03253 Front plate for vertical fixed NS250 with rotary 58handle, W=250mm03270 Front plate for horizontal fixed NS630 with toggle 3203271 Front plate for horizontal INS630 3803273 Front plate for vertical NS630 with toggle 3303274 Front plate for vertical INS630 3903275 Front plate for vertical NS630 with rotary handle or 33motor mechanism03276 Front plate for vertical Vigi NS630 with toggle 3303277 Front plate for vertical Vigi NS630 with rotary 33handle or motor mechanism03280 Front plate for vertical fixed NS630 with toggle, 58W=250mm03281 Front plate for vertical fixed INS630 with toggle, 60W=250mm03282 Front plate for fixed Vigi NS630 with toggle, 58W=250mm03283 Front plate for vertical NS630 with rotary handle or 58motor mechanism, W=250mm03312 Front plate for vertical INF32/40, 3P 4303313 Front plate for INF32/40, 4P and horizontal 3P 42, 4303314 Front plate for INF63-160, 3P and vertical INV63, 42, 433P03315 Front plate for vertical INF63, 4P and vertical 43INF16003342 Transparent front plate, 4 modules 13, 48, 5603343 Transparent front plate, 6 modules 49, 5603344 Transparent front plate, 9 modules 562


IndexCat. no Designation Pages Cat. no Designation Pages03345 Transparent front plate, 12 modules 5604054 Multi-stage distribution block, 4P, 400A 11203352 Transparent front plate, 4 modules,W=250mm 56, 64, 6804055 Multi-stage distribution block, 4P, 630A 11203353 Transparent front plate, 6 modules,W=250mm 56, 6804060 Power supply block for horizontal NS250 34, 38, 9903354 Transparent front plate, 9 modules,W=250mm 56, 6804061 Universal power supply block, 250A 35, 36, 37,03358 4 lead-sealable front plate screws 12839, 59, 61,9903801 Plain front plate, 1 module 13, 33, 34, 35,37, 38, 39, 48, 04062 Connection between vertical NS-INS250 and 35, 37, 39, 9949, 56universal power supply block03802 Plain front plate, 2 modules 33, 34, 35, 36, 04064 Connection between vertical NS-INS250 in duct 59, 61, 9937, 39, 40, 41,and universal power supply block42, 43, 5604065 Connection between vertical NS-INS250 in duct 59, 6103803 Plain front plate, 3 modules 13, 32, 33, 38,and busbars40, 48, 56, 117 04066 Incoming connection block for NS-INS250 34, 3803804 Plain front plate, 4 modules 33, 49, 56supplied via the top03805 Plain front plate, 5 modules 49, 56, 117 04067 Incoming connection block for NS-INS250 34, 38supplied via the bottom03806 Plain front plate, 6 modules 39, 49, 56, 11704070 Power supply block for horizontal NS400 32, 38, 9903807 Plain front plate, 9 modules 5604071 Power supply block for horizontal NS630 32, 38, 9903808 Plain front plate, 12 modules 5604073 Connection between vertical NS-INS400-630 in 59, 61, 9903811 Plain front plate, 1 module, W=250mm 58, 62, 64, 68duct and universal power supply block03812 Plain front plate, 2 modules, W=250mm 58, 60, 6804074 Universal power supply block, 400-630A 33, 39, 59, 61,03813 Plain front plate, 3 modules, W=250mm 64, 689903814 Plain front plate, 4 modules, W=250mm 65, 6804075 Connection between vertical NS-INS630 in duct 59, 6103815 Plain front plate, 5 modules, W=250mm 68and busbars03816 Plain front plate, 6 modules, W=250mm 6803817 Plain front plate, 9 modules, W=250mm 6803890 Front plate for fan or grill 13003891 IP30 ventilated front plate, 1 module 13103895 IP30 ventilated front plate, 3 modules 13103900 Plain mounting plate for 72x72mm meter 5003901 Plain mounting plate for 96x96mm meter 5003902 Mounting plate with cut-out for 72x72mm meter 5003903 Mounting plate with cut-out for 96x96mm meter 5003904 Front plate with cut-outs for meter mounting plates 5003907 Blanking plate, 72x72mm 5103908 Blanking plate, 96x96mm, for meters 5103910 Front plate with cut-outs for 72x72mm meters 5103911 Front plate with cut-outs for 96x96mm meters 51, 5203912 Front plate with cut-outs for 144x144mm + 4 5172x72mm meters03914 Front plate with holes for 22mm dia. pushbuttons 51and lamps03928 Visor for human/switchboard interface (HSI) 5003934 Front plate for Vigilohm TR22A+6 72x72mm 52meters0400004004 Multiclip distribution block, 4P, 80A, 1 row 14, 47, 11404008 Multiclip distribution block, 4P, 63A, 1/2 row 14, 47, 11404012 Multiclip distribution block, 2P, 200A, 1 row 47, 11504013 Multiclip distribution block, 3P, 200A, 1 row 47, 11504014 Multiclip distribution block, 4P, 200A, 1 row 47, 11504018 Multiclip distribution block, 4P, 160A, 1/2 row 47, 11504021 Powerclip busbar connection for 200A Multiclip 47, 99, 115distribution block04024 Duct busbar connection for 200A Multiclip 103, 115distribution block04029 Rear busbar connection for 200A Multiclip 101, 115distribution block04031 Polybloc distribution block, 1P, 160A 12, 11104033 Polybloc distribution block, 3P, 250A 34, 35, 36, 37,38, 39, 43, 59,61, 11004034 Polybloc distribution block, 4P, 250A 34, 35, 36, 37,38, 39, 43, 59,61, 11004037 4 Cu spacers for Polybloc 250A distribution block 3904045 Distribloc 125 12, 47, 10804046 Distribloc 160+connections 12, 47, 10804047 4 NG-INS125 connections for Distribloc 10904052 Multi-stage distribution block, 4P, 160A 11204053 Multi-stage distribution block, 4P, 250A 11204076 In-duct incoming connection block for NS630 3204103 Powerclip busbars, 125A, 3P, L=450mm 12, 9804104 Powerclip busbars, 125A, 4P, L=450mm 12, 9804107 Powerclip busbars, 125A, 3P, L=750mm 12, 9804108 Powerclip busbars, 125A, 4P, L=750mm 12, 9804111 Powerclip busbars, 160A, 3P, L=1000mm 12, 9904112 Powerclip busbars, 250A, 3P, L=1000mm 9904113 Powerclip busbars, 400A, 3P, L=1000mm 9904114 Powerclip busbars, 630A, 3P, L=1000mm 9904116 Powerclip busbars, 160A, 3P, L=1400mm 12, 9904117 Powerclip busbars, 250A, 3P, L=1400mm 9904118 Powerclip busbars, 400A, 3P, L=1400mm 9904119 Powerclip busbars, 630A, 3P, L=1400mm 9904121 Powerclip busbars, 160A, 4P, L=1000mm 12, 9904122 Powerclip busbars, 250A, 4P, L=1000mm 9904123 Powerclip busbars, 400A, 4P, L=1000mm 9904124 Powerclip busbars, 630A, 4P, L=1000mm 9904126 Powerclip busbars, 160A, 4P, L=1400mm 12, 9904127 Powerclip busbars, 250A, 4P, L=1400mm 9904128 Powerclip busbars, 400A, 4P, L=1400mm 9904129 Powerclip busbars, 630A, 4P, L=1400mm 9904145 4 connections, 125A 12, 98, 10104146 4 connections 160 A 10104146 4 connections, 160A 12, 9904150 8 IPxxB covers for Powerclip busbars 12, 9904151 12 Powerclip tap-off blocks with 6mm² + 10mm² 12, 99terminals04152 12 Powerclip tap-off blocks with 16mm² terminals 12, 9904155 Additional 35mm² block, 3P 99, 11104156 Additional 35mm² block, 4P 99, 11104158 20 screws for Powerclip busbars 12, 9904161 4 bars with threaded holes, 160A, L=1000mm 101, 10304162 4 bars with threaded holes, 250A, L=1000mm 101, 10304163 4 bars with threaded holes, 400A, L=1000mm 101, 10304171 4 bars with threaded holes, 160A, L=1400mm 101, 10304172 4 bars with threaded holes, 250A, L=1400mm 101, 10304173 4 bars with threaded holes, 400A, L=1400mm 101, 10304174 4 bars with threaded holes, 630A, L=1400mm 10304190 4 copper angle brackets, 250A 10104191 Rear busbar support 10104192 Multi-stage bar support for duct 10304194 20 M6x20mm bolts for 5mm bars 101, 10304195 40 M6x16mm screws for bars with threaded holes, 101, 103less than 630A04197 Busbar power supply barrier, 630A 10304198 Rear busbar barrier 1013


IndexCat. no Designation Pages Cat. no Designation Pages04200 Earth bar, 24 modules 14, 11808096 Transparent door for Pack enclosure, W=550mm, 1104201 Earth bar for direct earth blocks, 12x3mm 14, 1186 rows04202 2 earth bars, 12 modules 11804205 2 supports for earth bar on DIN rail 11904206 Fixing brackets for vertical earth bar in wall-mountor floor-standing enclosure, H=15mm04207 Fixing brackets for vertical earth bar in wall-mountor floor-standing enclosure, H=45mm04208 Fixing brackets for vertical earth bar in wall-mountor floor-standing enclosure, H=80mm14, 117, 119,120117, 119, 120117, 119, 12004210 Kit for neutral bar 12104214 4 earth blocks with 12x4mm² spring terminals 14, 11804215 4 earth blocks with 3x16mm² spring terminals 14, 11804220 Mounting plate for terminal block and earth bar in 116, 120duct04223 Mounting plate with 4 vertical DIN rails for terminal 117, 120blocks04224 5 Practic raisers 55, 6704226 Modular device rail, L=1600mm 54, 66, 11604228 Terminal block for auxiliaries 53, 12704233 Trunking for door, L=2000mm 53, 12704234 10 grommets for wiring through front 53, 12704235 Flexible trunking for wiring to door 53, 12704239 12 horizontal cable straps 14, 47, 12604243 4 covers for horizontal cable straps 14, 47, 12604255 12 horizontal trunking supports 14, 47, 12604257 4 horizontal trunking sections, L=450mm, + 14, 47, 127supports04263 2 covers for vertical cable straps, L=1000mm 47, 12604264 12 vertical cable straps, System G 47, 12604265 12 vertical trunking supports 47, 12604267 Vertical trunking, L=2000mm 47, 12704330 Vertical partition 9504331 Horizontal partition for wall-mount or floor-standing 94enclosure04332 Horizontal partition for duct 9404390 Réf 04390 dans fichier 100F22200.rtf pas trouvé 123dans indexe04742 Insulated flexible bar 20x2mm, L=1800mm 10404743 Insulated flexible bar 20x3mm, L=1800mm 10404746 Insulated flexible bar 24x5mm, L=1800mm 10404751 Insulated flexible bar 32x5mm, L=1800mm 10404752 Insulated flexible bar 32x6mm, L=1800mm 10404753 Insulated flexible bar 32x8mm, L=1800mm 1040800008002 Surface-mount Pack enclosure, W=550mm, 2 11rows08003 Surface-mount Pack enclosure, W=550mm, 3 11rows08004 Surface-mount Pack enclosure, W=550mm, 4 11rows08005 Surface-mount Pack enclosure, W=550mm, 5 11rows08006 Surface-mount Pack enclosure, W=550mm, 6 11rows08082 Plain door for Pack enclosure, W=550mm, 2 rows 1108083 Plain door for Pack enclosure, W=550mm, 3 rows 1108084 Plain door for Pack enclosure, W=550mm, 4 rows 1108085 Plain door for Pack enclosure, W=550mm, 5 rows 1108086 Plain door for Pack enclosure, W=550mm, 6 rows 1108092 Transparent door for Pack enclosure, W=550mm, 112 rows08093 Transparent door for Pack enclosure, W=550mm, 113 rows08094 Transparent door for Pack enclosure, W=550mm, 114 rows08095 Transparent door for Pack enclosure, W=550mm, 115 rows08102 Wall-mount enclosure, W=600mm, 6 modules 7408103 Wall-mount enclosure, W=600mm, 9 modules 7408104 Wall-mount enclosure, W=600mm, 12 modules 7408105 Wall-mount enclosure, W=600mm, 15 modules 7408106 Wall-mount enclosure, W=600mm, 18 modules 7408107 Wall-mount enclosure, W=600mm, 21 modules 7408108 Wall-mount enclosure, W=600mm, 24 modules 7408109 Wall-mount enclosure, W=600mm, 27 modules 7408122 Plain door for wall-mount enclosure, 6 modules 7408123 Plain door for wall-mount enclosure, 9 modules 7408124 Plain door for wall-mount enclosure, 12 modules 7408125 Plain door for wall-mount enclosure, 15 modules 7408126 Plain door for wall-mount enclosure, 18 modules 7408127 Plain door for wall-mount enclosure, 21 modules 7408128 Plain door for wall-mount enclosure, 24 modules 7408132 Transparent door for wall-mount enclosure, 6 74modules08133 Transparent door for wall-mount enclosure, 9 74modules08134 Transparent door for wall-mount enclosure, 12 74modules08135 Transparent door for wall-mount enclosure, 15 74modules08136 Transparent door for wall-mount enclosure, 18 74modules08137 Transparent door for wall-mount enclosure, 21 74modules08138 Transparent door for wall-mount enclosure, 24 74modules08172 Duct for wall-mount enclosure, W=300mm, 6 74modules08173 Duct for wall-mount enclosure, W=300mm, 9 74modules08174 Duct for wall-mount enclosure, W=300mm, 12 74modules08175 Duct for wall-mount enclosure, W=300mm, 15 74modules08176 Duct for wall-mount enclosure, W=300mm, 18 74modules08177 Duct for wall-mount enclosure, W=300mm, 21 74modules08178 Duct for wall-mount enclosure, W=300mm, 24 74modules08179 Duct for wall-mount enclosure, W=300mm, 27 74modules08182 Door for wall-mount enclosure duct, 6 modules 7408183 Door for wall-mount enclosure duct, 9 modules 7408184 Door for wall-mount enclosure duct, 12 modules 7408185 Door for wall-mount enclosure duct, 15 modules 7408186 Door for wall-mount enclosure duct, 18 modules 7408187 Door for wall-mount enclosure duct, 21 modules 7408188 Door for wall-mount enclosure duct, 24 modules 7408197 Transparent door for wall-mount enclosure duct, 7421 modules08198 Transparent door for wall-mount enclosure duct, 7424 modules08202 Floor-standing enclosure, W=600mm, 27 modules 7608203 Floor-standing enclosure, W=600mm, 30 modules 7608204 Floor-standing enclosure, W=600mm, 33 modules 7608212 Floor-standing enclosure extension, W=600mm, 7627 modules08213 Floor-standing enclosure extension, W=600mm, 7630 modules08214 Floor-standing enclosure extension, W=600mm, 7633 modules08222 Plain door for wall-mount and floor-standing 74, 76enclosure, 27 modules08223 Plain door for floor-standing enclosure, 30 76modules4


IndexCat. no Designation Pages Cat. no Designation Pages08224 Plain door for floor-standing enclosure, 33 76modules08232 Transparent door for wall-mount and74, 76floor-standing enclosure, 27 modules08233 Transparent door for floor-standing enclosure, 30 76modules08234 Transparent door for floor-standing enclosure, 33 76modules08272 Duct for floor-standing enclosure, W=300mm, 27 76modules08273 Duct for floor-standing enclosure, W=300mm, 30 76modules08274 Duct for floor-standing enclosure, W=300mm, 33 76modules08282 Door for wall-mount and floor-standing enclosure 74, 76duct, 27 modules08283 Door for floor-standing enclosure duct, 30 modules 7608284 Door for floor-standing enclosure duct, 33 modules 7608292 Transparent door for wall-mount and74, 76floor-standing enclosure duct, 27 modules08293 Transparent door for floor-standing enclosure 76duct, 30 modules08294 Transparent door for floor-standing enclosure 76duct, 33 modules08302 IP55 enclosure, 7 modules 8608303 IP55 enclosure, 11 modules 86, 8708304 IP55 enclosure, 15 modules 86, 8708305 IP55 enclosure, 19 modules 8608306 IP55 enclosure, 23 modules 8608307 IP55 enclosure, 27 modules 8608309 IP55 enclosure, 33 modules 8608312 IP55 enclosure extension, 7 modules 8608313 IP55 enclosure extension, 11 modules 86, 8708314 IP55 enclosure extension, 15 modules 8608315 IP55 enclosure extension, 19 modules 8608316 IP55 enclosure extension, 23 modules 8608317 IP55 enclosure extension, 27 modules 8608319 IP55 enclosure extension, 33 modules 8608322 IP55 plain door, 7 modules 8608323 IP55 plain door, 11 modules 8608324 IP55 plain door, 15 modules 8608325 IP55 plain door, 19 modules 8608326 IP55 plain door, 23 modules 8608327 IP55 plain door, 27 modules 8608329 IP55 plain door, 33 modules 8608332 IP55 transparent door, 7 modules 8608333 IP55 transparent door, 11 modules 8608334 IP55 transparent door, 15 modules 8608335 IP55 transparent door, 19 modules 8608336 IP55 transparent door, 23 modules 8608337 IP55 transparent door, 27 modules 8608339 IP55 transparent door, 33 modules 8608342 IP55 duct, W=300mm, 7 modules 8608343 IP55 duct, W=300mm, 11 modules 8608344 IP55 duct, W=300mm, 15 modules 86, 8708345 IP55 duct, W=300mm, 19 modules 8608346 IP55 duct, W=300mm, 23 modules 8608347 IP55 duct, W=300mm, 27 modules 8608349 IP55 duct, W=300mm, 33 modules 8608352 IP55 side panels, 7 modules 8608353 IP55 side panels, 11 modules 86, 8708354 IP55 side panels, 15 modules 8608355 IP55 side panels, 19 modules 8608356 IP55 side panels, 23 modules 8608357 IP55 side panels, 27 modules 8608359 IP55 side panels, 33 modules 8608362 IP55 side panels with cut-outs, 7 modules 8808363 IP55 side panels with cut-outs, 11 modules 8808364 IP55 side panels with cut-outs, 15 modules 8808365 IP55 side panels with cut-outs, 19 modules 8808366 IP55 side panels with cut-outs, 23 modules 8808367 IP55 side panels with cut-outs, 27 modules 8808369 IP55 side panels with cut-outs, 33 modules 8808371 Top and bottom plates, W=600mm 86, 8708372 Top and bottom plates, W=300mm 86, 8708374 IP55 4-module partial plain door for 11-27 module 88enclosures08375 IP55 6-module partial plain door for 33-module 88enclosures08376 IP55 4-module partial door with cut-outs for 11-27 88module enclosures08377 IP55 6-module partial door with cut-outs for 8833-module enclosures08378 IP55 4-module partial TEGO door for 11-27 88module enclosures08379 IP55 6-module partial TEGO door for 33-module 88enclosures08381 IP55 horizontal/vertical combination kit 8708382 IP55 L combination kit 8708383 IP55 square combination kit 8708386 Canopy for IP55 enclosures, W=600mm 9108387 Canopy for IP55 duct, W=300mm 9108391 IP55 mounting upright 87, 9008392 IP55 plinth gusset 9008393 IP55 plinth cover panels, W=600mm 9008394 IP55 plinth cover panels, W=300mm 9008395 Pole-mount kit for enclosures 9108396 2 IP55 lifting rings 9108801 2 lifting rings 8008803 4 external wall-mount brackets 15, 8108805 100mm plinth raiser for floor-standing enclosures 7708807 100mm plinth raiser for ducts 7708810 2 lifting/reinforcement cross-members for single 80wall-mount or floor-standing enclosures08811 2 lifting/reinforcement cross-members for 2 75, 77, 80wall-mount or floor-standing enclosures08812 2 lifting/reinforcement cross-members for single 75, 77, 80wall-mount or floor-standing enclosure and duct08813 2 lifting/reinforcement cross-members for two 75, 77, 80wall-mount or floor-standing enclosures and a duct08816 Combination kit 7508817 2 combination uprights 7508818 Multiple combination kit 7508819 Flush-mount kit for wall-mount enclosures, 6-18 78modules08820 Flush-mount kit for wall-mount enclosures, 21-27 78modules08821 Trunking spreader for Pack enclosure 1108822 Pack flush-mount kit 1108824 Trunking spreader for wall-mount or floor-standing 80enclosure08830 IP31 canopy for wall-mount or floor-standing 78enclosure08831 IP31 canopy for 2 wall-mount or 2 floor-standing 78enclosures08832 IP31 canopy for single wall-mount or floor-standing 78enclosure and duct08833 IP31 canopy for 2 wall-mount or 2 floor-standing 78enclosures and duct08840 IP43 door gasket kit, 6-21 modules 7808841 IP43 door gasket kit, 24-33 modules 7808850 6-module partial door for wall-mount or78floor-standing enclosure08851 6-module partial door with cut-out for human/ 78switchboard interface (HSI) for wall-mount orfloor-standing enclosure08861 Plain mounting plate, 210x150mm 8908862 Mounting plate with eight 22mm diameter holes 8908863 Mounting plate with two 70x85mm holes for 89industrial sockets5


IndexCat. no Designation Pages Cat. no Designation Pages08864 IP55 mounting plate with 70x85mm and8990x100mm holes for industrial sockets08865 Mounting plate with 90x180mm hole for industrial 89sockets08866 Cable tie support adapter 12408867 3408867 2 cable tie supports for wall-mount or15, 34, 124floor-standing enclosure08868 4 cable tie supports for ducts 12408870 Plain metal gland plate for wall-mount or 79floor-standing enclosure08871 Interface for FL21 gland plate for wall-mount or 79floor-standing enclosure08874 Plain metal gland plate for duct 7908875 Interface for FL21 gland plate for duct 7908878 Plastic gland plate and interface for Pack 11enclosures08879 Plain metal gland plate for Pack enclosures 1108880 Plastic gland plate and interface for wall-mount or 79floor-standing enclosure08881 Plain FL21 gland plate 7908884 Plastic gland plate and interface for ducts 7908887 Gland plate for floor-standing enclosure plinth 7908888 Gland plate for duct plinth 7908891 Not yet available 7908892 Not yet available 7908895 FL21 gland plate with 20x16mm diameter entries 7908896 FL21 gland plate with 16/30/47mm diameter 79entries08897 FL21 gland plate with 2x66mm diameter entries 7908898 FL21 gland plate with 39x7-26mm diameter entries 9108899 FL21 IP55 gland plate with 2x33-72mm diameter 91entries08900 Switchboard identification plate 12808903 12 adhesive label holders, H=24mm, W=432mm 15, 12908904 12 adhesive label holders, H=36mm, W=432mm 15, 12908905 12 adhesive label holders, H=24mm, W=180mm 12908906 12 adhesive label holders, H=36mm, W=180mm 12908907 12 adhesive label holders, H=24mm, W=650mm 15, 12908908 12 adhesive label holders, H=36mm, W=650mm 15, 12908910 Earthing braid, 6mm² 15, 12908911 Earthing wire, 6mm² 15, 12908913 12 clip-on labels, 18x35mm 15, 12808914 12 engraving plates, 18x35mm 15, 12808915 12 clip-on labels, 18x72mm 15, 12808916 12 engraving plates, 18x72mm 15, 12808917 12 clip-on labels, 25x85mm 15, 12808918 12 engraving plates, 25x85mm 15, 12808930 Standard handle without insert 8208932 EURO handle without insert 8208933 ASSA handle without insert 8208934 IP55 EURO handle for cylinder 9208935 IP55 handle, L=155mm 9208936 IP55 door latch with lock and 2 no. 405 keys 9208938 Handle padlocking kit 8208939 IP55 handle padlocking kit 9308940 Barrel lock no. 405 8208941 Barrel lock no. 455 8208942 Barrel lock no. 1242E 8208943 Barrel lock no. 3113A 8208944 Barrel lock no. 2433A 8208945 DIN double bar insert 8208946 Screwdriver slot insert 8208947 6.5mm male triangle insert 8208948 7mm male triangle insert 8208949 8mm male triangle insert 8208950 9mm male triangle insert 8208951 6mm male square insert 8208952 7mm male square insert 8208953 8mm male square insert 8208955 6mm female square insert 8208961 Touch-up paint brush 15, 12908962 Touch-up spray paint 15, 12908963 Adhesive drawing holder 15, 12908964 Switchboard lighting 5608987 Fan 13008988 Grill with filter 13008989 5 standard filters 13008990 5 fine filters 13008992 Resistor, 55W 13108993 Resistor, 90W 13108994 Resistor, 250W 13108998 Thermostat 1310900009931 IP55 screwdriver slot insert 9209932 IP55 3mm double bar insert for handle 9209933 IP55 barrel + 2 no. 2433A keys 9209937 IP55 7mm male triangle insert for handle 9209938 IP55 8mm male triangle insert for handle 92(CNOMO)09939 IP55 9mm male triangle insert for handle (EDF) 9209942 IP55 barrel + 2 no. 1242E keys 9209943 IP55 barrel + 2 no. 3133A keys 9209945 IP55 barrel + 2 no. 455 keys 9209946 IP55 6mm female square insert for handle 9209947 IP55 7mm male square insert for handle 9209948 IP55 8mm male square insert for handle 9209949 IP55 6mm male square insert for handle 9209981 IP55 screwdriver slot insert for door 9209982 IP55 3mm double bar insert for door 9209983 IP55 7mm male triangle insert for door 9209984 IP55 8mm male triangle insert for door (CNOMO) 9209985 IP55 9mm male triangle insert for door (EDF) 9209986 IP55 6mm male square insert for door 9209987 IP55 7mm male square insert for door 9209988 IP55 8mm male square insert for door 9209989 IP55 6mm female square insert for door 921300013735 10 self-adhesive label sheets for common symbols 15, 12913736 10 self-adhesive label sheets for special symbols 15, 1296


General presentationSystem G<strong>Prisma</strong> <strong>Plus</strong>electrical switchboardsup to 630 APresentation<strong>Prisma</strong> <strong>Plus</strong> - a tried and tested modular systemA dependable electrical installationThe total compatibility of Schneider devices with the <strong>Prisma</strong> <strong>Plus</strong> system is a keyadvantage in ensuring a high level of installation dependability.System design has been validated by type tests as per standard IEC 60439-1 andbenefits from the combined experience of Schneider customers over many years.An upgradeable electrical installationThanks to modular design, <strong>Prisma</strong> <strong>Plus</strong> switchboards can be modified easily tointegrate new functions as needed.Maintenance operations, carried out with the switchboard de-energised, are fast andstraight-forward due to easy access to devices.Total safety for personnelWork in a <strong>Prisma</strong> <strong>Plus</strong> switchboard is risk-free when carried out by qualified personsin compliance with all applicable safety regulations.Devices are installed behind protective front plates and only the operating handlesare accessible.Additional internal separations protect against direct contact with live parts.Terminal shields are mandatory for installation of Compact NS and Interpact INS/INVdevices in <strong>Prisma</strong> <strong>Plus</strong> enclosures.8


General presentationSystem G<strong>Prisma</strong> <strong>Plus</strong>electrical switchboardsup to 630 APD390670PD390665PresentationSystem GIP55 enclosures.IP30/31/43wall-mountand floorstandingenclosures.Pack wall-mount enclosuresb Applications:v indoor enclosures containing all modular devices, for distribution switchboards insmall and medium-sized commercial buildings (hotels, offices, shops), or formedium-sized and large residential installations (houses)v supplied mounted, with modular rails and front plates (48 modules (9 mm) per row)b rated operational current: 160 Ab degree of protection: IP30 with or without doorb degree of protection against mechanical impacts:v IK07 (without door)v IK08 (with door)b enclosure dimensions:v five heights: 480 mm to 1080 mmv width: 555 mmb depth: 157 mm without doorv 186 mm with door and handle.IP30/31/43 wall-mount and floor-standing enclosuresb Applications:v indoor wall-mount and floor-standing enclosures for all types of low-voltageswitchboards (main, subdistribution and final) in commercial and industrialenvironmentsv supplied in kit form, can be combined side-by-side and one on top of anotherb rated operational current: 630 Ab degree of protection:v IP30: with or without doorv IP31: with door + canopyv IP43: with door + canopy + gasketb degree of protection against mechanical impacts:v IK07 (without door)v IK08 (with door)b enclosure dimensions:v eleven heights: 330 mm to 1830 mm (including the plinth for floor-standingenclosures)v two widths: 595 mm and 305 mm (duct)v depth: 205 mm without doorv 250 mm with door + handleIP55 enclosuresb Applications:v indoor enclosures for distribution, protection and process control in commercialand industrial applicationsv supplied in kit form, can be combined side-by-side and one on top of anotherb rated operational current: 630 Ab degree of protection: IP55b degree of protection against mechanical impacts: IK10b enclosure dimensions:v seven heights: 450 mm to 1750 mmv width: basic enclosure: 600 mmv extensions: 575 and 325 mm (duct)v depth: 260 mm + 30 mm (handle).9


EnclosuresSystem GPack wall-mount enclosuresup to 630 ACatalogue numbersPresentationPack electrical-distribution enclosures are speciallydesigned for modular devices up to 160 A.The design, based on the System G wall-mount andfloor-standing enclosures, offers a number ofadvantages:b easy device access and mountingb distribution using 125 and 160 A Powerclip insulatedbusbars as well as Distribloc and Polybloc distributionblocksb supply of devices using 63/80 A Multiclip distributionblocks or comb busbarsb horizontal cable straps and trunkingb earth and neutral barsb identification labelsb closing accessories including barrel locks andinserts.The optimised depth and extra-thin door ensure perfectintegration in all environments.In addition, Pack enclosures are specially equipped foreasy on-site installation.Supplied with modular rails and front plates alreadymounted, they can also be fitted with blanking platesand plastic gland plates.They can be equipped with plain or transparent doors.Characteristicsb rated operational current: 160 Ab degree of protection: IP30 (with or without door)b degree of protection against mechanical impacts:IK07 (without door), IK08 (with door)b insulation: class 1b compliance with standards: IEC 60439-1b dimensions:v H: see the table on the next pagev W: 555 mmv D: 157 mm without door186 mm without doorb Capacity per row: 48 width modules (9 mm each).PD390536PD390550PD39055110


EnclosuresSystem GPack wall-mount enclosuresCatalogue numbersDD381811EnclosuresDD381800DD381801DD381802No. of rows Height ofenclosureEnclosure Plain door Transparentdoor2 480 08002 08082 080923 630 08003 08083 080934 780 08004 08084 080945 930 08005 08085 080956 1080 08006 08086 08096Reversible doors (opening to left or right), equipped with a handle (without barrellock).For barrel locks and inserts, see page 82.DD381812Gland platesDesignationCat. no.Top or bottom plate with additional plastic gland plate 08878Plain metal gland plate 0887908878.DD38181308879.DD381814Trunking spreaderDesignationCat. no.Trunking spreader 08821DD381256Flush-mount kitDesignationCat. no.Flush-mount kit 0882211


EnclosuresSystem GPack wall-mount enclosuresDistributionCable runningCatalogue numbersDD381815160 A Powerclip busbarssee page 99.Available in two lengths (450 and 750 mm) in three and four-pole versions.The busbars can be cut to length every 150 mm.They are supplied with clip-on covers that block off the connected cable lugs and canbe cut as needed.Cat. no. selection125 A Powerclip busbars Cat. no.Three-pole L = 450 mm 04103L = 750 mm 04107Four-pole L = 450 mm 04104L = 750 mm 04108160 A Powerclip busbars Cat. no.Three-pole L = 1000 mm 04111Four-pole L = 1000 mm 04121Busbar connectionFour 125 A connections, L = 230 mm04145(for NG125, NSA and INS equipped with tunnel terminals)A 35 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.95 mm² tunnel terminals for INS : cat. no. 28947 (set of 3)cat. no. 28948 (set of 4)DD381379Four 160 A connections, L = 250 mm(for NSA160)A 45 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.04146DD381816DD381817Powerclip tap-off blocksEach block can be used to connect:b one 6 mm² and one 10 mm² cable (04151)b one 16 mm² cables (04152).Equipped with spring terminals.DesignationCat. no.12 Powerclip tap-off blocks with 6 mm² + 10 mm² terminals 0415112 Powerclip tap-off blocks with 16 mm² terminals 04152Connection coverClip-on covers that block off the connected cable lugs and can be cut as needed.They maintain the IPxxB value for cables from 10 to 25 mm² with 90° angle lugs.DesignationCat. no.8 IPxxB covers for Powerclip busbars 041508.8 class mounting hardwareUsed for electrical connections to the copper bars.DesignationCat. no.Set of 20 CHC M6 x 12 mm screws for Powerclip busbars 04158DD381200160 A Polybloc distribution blocksee page 110.DesignationCat. no.160 A Polybloc distribution block, 1P 04031Insulation voltage Ui: 750 V ACNominal current: 160 (40 °C)Upstream connection: tunnel terminals up to 70 mm 2Downstream connections: spring loaded terminals up to 6 x 16 v flexible or rigid.rtioDD381818125/160 A Distribloc distributionblocksee page 108.DesignationCat. no.125 A Distribloc distribution block 04045160 A Distribloc distribution block 0404612


DD381806EnclosuresSystem GCatalogue numbersInstallation on a modular railPack wall-mount enclosuresDevice on a modular railDevice on a slotted plateNSA125/160, NG125 circuit breakerDepth behindfront plate (mm)Useful length(mm)DesignationCat. no.Rear modular rail 79 432 03004DD381807Installation on a slotted mountingplateDesignationRecessed slottedmounting plateNo. ofverticalmodulesUseful height(mm)Useful width(mm)Depth behindfront plateCat. no.6 300 420 112 03172DD382565DD382564DD382661NG125 circuit breakerNSA125/160 circuit breakerFront plateNo. ofverticalmodulesModular railModularront plateDesignationNG1256 b 03205 03801Vigi NG125Direct supply via cables.Capacity of modular rail: 48 Multi 9 modules.Width of devices: NG125 3P: 9 modulesNG1250 4P: 12 modules63 A instantaneous or séelective 3P: 18 modules63 A instantaneous or séelective 4P: 21 modules63 A adjustable I/S/R 3P: 20 modules63 A adjustable I/S/R 4P: 23 modulesNo. ofverticalmodulesModular railModular frontplatePlain front platePlain front plateDesignationNSA125/160 circuit 6 03008 03205 03801breakerVigi circuit breakerNSA125/160Capacity of modular rail: 48 Multi 9 modules.Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device)the symmetrical rail + raiser set (28041).Width of devices: NSA125/160 3P: 10 modulesNSA125/160 4P: 14 modulesVigi NSA125/160 3P: 24 modulesVigi NSA125/160 4P: 27 modulesHeigh Plain front plateTransparent front platein mmDesignation1 module (H = 50 mm) 50 038013 modules (H = 50 mm) 150 038034 modules (H = 200 mm) 200 03342Other solutionssee page 5413


EnclosuresSystem GPack wall-mount enclosuresDistributionCable runningCatalogue numbersDD382657Multiclip distribution blocksee page 114.DesignationCat. no.80 A Multiclip, 4P 0400463 A Multiclip, 4P, 1/2 row 04008Comb busbarssee page 47.DD382658DD382659Cable runningsee page 126.DesignationCat. no.Cable straps12 horizontal cable straps 042394 covers for horizontal cable straps, L = 430 mm 04243Trunking4 horizontal sections, 60 x 30 mm, L = 450 mm + supports 0425712 horizontal trunking supports 042552 fixing brackets, H = 15 mm (for vertical trunking) 04206DD382653Earth barsee page 118.04201.PresentationThe earth bar can be:b a bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with a 35mm² tunnel terminal and on which earth blocks with spring terminals can be clippedb an earth bar (200 or 450 mm long), equipped with clamps with captive screws.Earth bar with spring terminalsCat. no.Bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with 04201a 35 mm² tunnel terminal (for earth blocks with spring terminals)4 earth blocks with 12 x 4 mm² spring terminals (L = 75 mm) 042144 earth blocks with 3 x 16 mm² spring terminals (L = 37 mm) 042152 fixing brackets, H = 15 mm (for vertical earth bar) 04206DD38151604214. 04215.Earth bar with clampsCat. no.Earth bar with 40 clamps + one 35 mm² terminal (L = 450 mm) 0420004200.DD382660Neutral barsee page 121.A neutral bar is created by inserting insulating spacers behind an earth bar.DesignationCat. no.Kit for neutral bar 0421014


EnclosuresSystem GPack wall-mount enclosuresAccessoriesCatalogue numbersDD382615Blanking platessee page 128.DesignationCat. no.Blanking strip, H = 46 mm, L = 1 m 032204 divisible blanking plates, H = 46 mm, L = 90 mm 03221DD382616Identification labelssee page 128.DesignationCat. no.Clip-on labels12 clip-on labels 18 x 35 0891318 x 72 0891525 x 85 0891712 engraving plates 18 x 35 08914Clip-on labels. 18 x 72 0891625 x 85 08918Adhesive labels12 adhesive label holders, W = 432 mm H = 24 mm 08903H = 36 mm 0890412 divisible label holders, W = 650 mm H = 24 mm 08907H = 36 mm 08908Symbol sheetsAdhesive labels. Set of ten adhesive symbol sheets standard 13735special 13736DD382617DD382618Enclosure accessoriessee page 129.DesignationCat. no.Earthing braid, 6 mm² 08910Earthing wire, 6 mm² 08911DD382619DD382620DesignationCat. no.Touch-up spray paint, RAL 9001 08962Touch-up paint brush, RAL 9001 08961DD382621DesignationCat. no.Adhesive drawing holder 08963DD382613Cable-tie supportsDesignationCat. no.2 cable-tie supports 08867DD382614Wall mountingDesignationCat. no.4 external wall-mount brackets 0880315


System G contentsGeneral presentation 18Electrical switchboards up to 630 A 18Examples of switchboard configurations 20Cat. no. selection 26Typical configuration with catalogue numbers 26Determining catalogue numbers 30Functional units 32Compact NS400/630 32Compact NS100/250 34Interpact INS-INV250/630 38Manual source changeover system 40Fupact INF 42Modular devicesNG125 circuit breakersNSA125/160 circuit breakersINS40/160 switch-disconnectors 44Industrial control devices 48Human-switchboard interface 50Other devices 54Switchboard lighting 56Reserve space 56300 mm wide functional units 58Compact NS100/630 58Interpact INS-INV250/630 60Modular devicesNSA125/160 circuit breakersINS40/160 switch-disconnectors 62Industrial control devices 64Other devices 66Fixing accessories 67Reserve space 68Enclosures 70IP30/IP31/IP43 wall-mount enclosuresPresentation 70IP30/IP31/IP43 floor-standing enclosuresPresentation 72IP30/IP31/IP43 wall-mount enclosures 74IP30/IP31/IP43 floor-standing enclosures 76IP30/IP31/IP43 enclosures 78Enclosure accessories 82IP55 enclosures Presentation 84IP55 enclosures Enclosure 86Partitioning 94Distribution 96Main distribution 96630 A Powerclip busbars 98400 A rear busbars 100630 A multi-stage busbars 102Insulated flexible bars 104Overview of distribution blocks 106Distribloc distribution block 108Polybloc distribution block 110160/630 A multi-stage distribution block 112Multiclip distribution block 114Terminal blocks support 116Earth bars 118Neutral bars 121Terminal blocks 122IP30/31/43/55 enclosures 124Cable running 126Front plate accessories 128Air-conditioning accessories 13017


General presentationSystem GElectrical switchboardsup to 630 APresentationPD39528The <strong>Prisma</strong> <strong>Plus</strong> functionalsystemThe <strong>Prisma</strong> <strong>Plus</strong> functional system can be used for all types of low-voltagedistribution switchboards up to 630 A, in commercial and industrial environments.Switchboard design is very simple.A functional structure for devicesmade up of wall-mount and floor-standing enclosures that can be used alone orcombined.A distribution systemmade up of centralised distribution blocks and vertical busbars installed on the sideor in the rear of the switchboard.Complete functional unitsEach device is part of a functional unit comprising:b a dedicated mounting plate for device installationb a front plate to block direct access to live partsb prefabricated busbar connectionsb systems for on-site connections and running of auxiliary wires.The functional units are modular and are arranged rationally, one on top of another,within the enclosure.The system includes everything required for functional unit mounting, supply and onsiteconnection.The components of the <strong>Prisma</strong> <strong>Plus</strong> system and those of the functional units inparticular have been designed and tested taking into account device characteristics.This design approach ensures a high degree of reliability in system operation andoptimum safety for personnel.PD390441Functional units are arranged rationally, one on top of another.18


General presentationSystem GElectrical switchboardsup to 630 APresentationPD390530<strong>Prisma</strong> <strong>Plus</strong> enclosuresAdvantages of <strong>Prisma</strong> <strong>Plus</strong>switchboardsElectrical characteristicsb steel sheet metalb electrophoresis treatment + hot-polymerised polyester epoxy powder, white colourRAL 9001.b IP30 / 31 / 43 wall-mount enclosuresv degree of protection:- IP30: with or without door- IP31: with door + canopy- IP43: with door + canopy + IP43 gasketv IK07 (without door), IK08 (with door)v can be dismantledv can be combined side by side and one on top of anotherv eight heights from 330 to 1380 mmv width: 595 mmv width of duct: 305 mm, can be combined side by sidev depth: 250 mm with door (205 mm without door)b IP30 / 31 / 43 floor-standing enclosuresv degree of protection:- IP30: with or without door- IP31: with door + canopy- IP43: with door + canopy + IP43 gasketv IK07 (without door), IK08 (with door)v can be dismantledv can be combined side by sidev three heights: 1530, 1680 and 1830 mmv width: 595 mmv width of duct: 305 mm, can be combined side by sidev depth: 250 mm with door (205 mm without door)b IP55 enclosuresv IK10v can be dismantledv can be combined side by side and one on top of anotherv width: 600 mmv seven heights: 450 to 1750 mmv widths: 325 and 575 mm, can be combined side by side and one on top of anotherv depth: 260 mm with door + 30 mm (handle).A dependable electrical installationThe total compatibility of Schneider devices with the <strong>Prisma</strong> <strong>Plus</strong> system is a keyadvantage in ensuring a high level of installation dependability.System design has been validated by type tests and benefits from the combinedexperience of Schneider customers over many years.An upgradeable electrical installationThanks to modular design, <strong>Prisma</strong> <strong>Plus</strong> switchboards can be modified easily tointegrate new functional units as needed.Maintenance operations, carried out with the switchboard de-energised, are fast andstraight-forward due to easy access to devices and the use of standard components.Total safety for personnelDevices are installed behind protective front plates; only the operating handles areaccessible.The electrical installation and operating personnel are fully protected.In addition, all distribution components are protected by an IPxxB degree ofprotection.Terminal shields are mandatory for installation of Compact NS and INS/INV devicesin <strong>Prisma</strong> <strong>Plus</strong> enclosures.Electrical switchboards built using the <strong>Prisma</strong> <strong>Plus</strong> functional system andSchneider recommendations fully comply with international standard IEC60439-1.<strong>Prisma</strong> <strong>Plus</strong> components comply with standard IEC 60439-1 and have the followingelectrical characteristics:b rated insulation level of main busbars at rear of enclosure: 1000 Vb rated operational current Ie (40°C): 630 Ab rated peak withstand current Ipk: 53 kÂb rated short-time withstand current Icw: 25 kA rms / 1 secondb frequency: 50/60 Hz.19


General presentationSystem GExamples of switchboardconfigurationsPresentationIncomerCompact NS250 4PFixed, front connectionToggleIncoming cables via bottomto incoming connection blockPD390444DistributionPolybloc distribution blockOutgoing devicesMulti 9 devicesSupplyCable runningConnectionMotor circuit breakersSupplyCable runningConnection80 A MulticlipComb busbarsStraps + coverTerminal block at top ofswitchboardComb busbarsStraps + coverTerminal block at top ofswitchboardIP30 enclosureWall-mount enclosure, W = 595 mm, H = 930 mmPlain doorPartial plain doorPD39044320


General presentationSystem GExamples of switchboardconfigurationsPresentationIncomerInterpact INS160 4PIncoming cables via topPD390446Distribution160 A Powerclip busbarsOutgoing devicesMulti 9 devicesSupply80 A MulticlipComb busbarsStraps + coverCable runningConnectionTerminal block in duct,W = 300 mmMotor circuit breaker + contactor combinationsSupplyCable runningConnectionCable wiringStraps + coverTerminal block in duct,W = 300 mmIP30 enclosureWall-mount enclosure,W = 595 mm, H = 1230 mmTransparent doorDuct, W = 305 mm,H = 1230 mmPlain doorPD39044521


General presentationSystem GExamples of switchboardconfigurationsPresentationIncomerCompact NS250Fixed, front connectionToggleIncoming cables via top to incoming connection blockPD390527DistributionPowerclip busbarsOutgoing devicesMulti 9 devicesSupplyCable runningConnectionMotor circuit breakersSupplyCable runningConnection80/200 A MulticlipComb busbarsStraps + coverTrunkingTerminal block in duct,W=300mmCable wiringTrunkingTerminal block in duct,W=300mmIP30 enclosureWall-mount enclosure, Transparent doorW = 595 mm, H = 1230 mmDuct, W = 305 mm, Plain doorH = 1230 mmPD39053122


General presentationSystem GExamples of switchboardconfigurationsPresentationIncomerInterpact INS160Lateral handleIncoming cables via bottom, directly to devicePD390451DistributionDistribloc distribution blockOutgoing devicesMulti 9 devicesSupplyComb busbarsCable runningStraps + coverConnectionTerminal block at bottom ofenclosureMotor control and protection devicesSupplyComb busbarsCable runningTrunkingConnectionTerminal block at bottom ofenclosureIP55 enclosureWall-mount enclosure, W = Transparent door595 mm, H = 1250 mmPD39045023


General presentationSystem GExamples of switchboardconfigurationsPresentationIncomerCompact NS400Fixed, front connectionToggleIncoming cables via bottom in duct (W = 300 mm) to incomingconnection blockPD390449DistributionPowerclip busbarsOutgoing devicesCompact NS250Fixed, front connectionToggleSupplyMulti 9 devicesSupplyPowerclip busbars with powersupply blockComb busbars200 A MulticlipCable runningTrunkingConnectionVertical terminal block at bottom offloor-standing enclosureMotor control and protection devicesSupply200 A MulticlipCable runningTrunkingConnectionVertical terminal block at bottom offloor-standing enclosureIP30 enclosureFloor-standing enclosure, Transparent doorW = 595 mm, H = 1830 mmDuct, W = 305 mm, Plain doorH = 1830 mm24


General presentationSystem GExamples of switchboardconfigurationsPresentationPD39059825


Cat. no. selectionSystem GTypical configuration withcatalogue numbersPresentationPD39067412345Device compartment See page 70Connection compartment See page 70Front plate See page 70Transparent door See page 74Plain door See page 7427


Cat. no. selectionSystem GDetermining catalogue numbersPresentationStarting with the electricaldiagram: IP30 switchboardDD380887DD381888Install the incomersee page 34b order the mountingplates and the frontplatesb the incomingconnection blockb the power supply blockfor the Powerclip busbars.DD381877Installation/connection1Device No. ofverticalmodulesFixed Compact NSDD381974MountingplateCut-out Upstreamfront plate front plateConnection blockcablesvia topcablesvia bottom2DD381878Distribution usingPowerclip busbarsDD381975Device Power supply block Terminal shields (set of 2) Powerclip busbarsFixed Compact NS and Vigicompact NSDD381888Install the modular devicesMulti 9Order the mountingplates and front platestaking into account:b supply to the rowsb cable running.Device No. of vertical1see page 44modulesAll Multi 9 devicesAll supply systems (comb busbars, Multiclip)with cable straps and trunking sectionsMulti 9 devicesSupply via 63/80 A Multiclip or combbusbars with cable strapsSupply via 63/80 A Multiclip or combbusbars with cable strapsDD381879DD381976Modular railModularfront plateDD381881DD381977DeviceAll Multi 9 devicesAll supply systems (comb busbars, Multiclip)with cable straps and trunking sectionsMulti 9 devicesSupply via 63/80 A Multiclip or combbusbars with cable strapsNo. of verticalmodulesModular railModularfront plate2DD381880TeSys "U"see page 48DD381978DeviceNo. ofverticalmodulesTeSys U modelTeSys U modelUsefullength of rail(mm)Rearmodular railTransparentfront plateb Multiclip distribution block see page 114b cable running see page 126Determine the size of the switchboardb count the number ofoccupied modules19 modulesb determine thecorresponding wallmountenclosure21 modulesb order the additionalplain front plate.Plain front platesee page 68DD381979500 mm wide plain front plateCat. no.30


Functional unitsSystem GCatalogue numbersInstallationCompact NS400/630HorizontalFixedToggleConnection to the in-duct incoming connection blockDD380782Cables via top to in-duct incoming connection block.Device No. of Mounting Cut-out frontvertical plate platemodulesCompact NS installed at top of switchboardNS400/630(cablesvia top)NS400/630(cablesvia bottom)Compact NS installed at bottom of switchboardNS400/630(cablesvia bottom)NS400/630(cablesvia top)Upstreamfront plateIncomingconnectionblock9 03070 03270 03803 040766 03070 03270 040769 03070 03270 03803 040766 03070 03270 04076DD380781Cables via bottom to in-duct incoming connection block.DD380783DistributionPowerclip insulated busbarsDevice Power supply block Powerclip insulated busbarsCompact NSNS400 04070 see page 99NS630 04071 see page 99Powerclip insulated busbars, supplied by 400 A power supplyblock (04070).Other distribution solutionsDD380777DD380761Rear busbarssee page 100.Multi-stage busbarssee page 102.32


DD380784Functional unitsSystem GCatalogue numbersInstallationCompact NS400/630VerticalFixedToggle or direct rotary handleToggleDeviceNo. ofverticalmodules (1)MountingplateCut-outfront plateUpstreamfront plateDownstreamfrontplateLongterminalshields(set of 2)Compact NS and Vigicompact NSNS400 11 03073 03273 03802 32564 (3P)32565 (4P)NS630 12 03073 03273 03802 03801 32564 (3P)32565 (4P)Vigi NS400 13 03073 03276 03802 32564 (3P)32565 (4P)Vigi NS630 14 03073 03276 03802 03801 32564 (3P)32565 (4P)(1) With or without spreaders.DD380785Direct rotary handleDeviceNo. ofverticalmodules (1)MountingplateCut-outfront plateUpstreamfront plateDownstreamfront plateLongterminalshields(set of 2)Compact NS and Vigicompact NSNS400 14 03074 03275 03802 03803 32564 (3P)32565 (4P)NS630 14 03074 03275 03802 03803 32564 (3P)32565 (4P)Vigi NS400 17 03074 03277 + 03802 03804 32564 (3P)2928532565 (4P)(collar)Vigi NS630 17 03074 03277 + 03802 03804 32564 (3P)2928532565 (4P)(collar)(1) With or without spreaders.DD381345DistributionPowerclip insulated busbarsDevicePower supply block(without connection)Short terminal shields(set of 2)Powerclip insulatedbusbarsCompact NS and Vigicompact NSNS400/630 and Vigi 3P 04074 32562 see page 994P 04074 32563Powerclip insulated busbars, supplied by power supply block(04074) (supplied without connection).Other distribution solutionsDD380777DD380761Rear busbarssee page 100.Multi-stage busbarssee page 102.33


DD380586DD380585Functional unitsSystem GCatalogue numbersInstallationCompact circuit breaker with incoming connection block(04066).Compact NS100/250HorizontalFixed or plug-inToggleWithout cable duct: with incoming connection blockDeviceNo. ofverticalmodulesMountingplateCut-outfront plateUpstreamfront plateConnection blockcables viatopcables viabottomFixed Compact NSNS100/250 5 03030 03230 03801 04066 or 04067Without cable duct: connection directly by cableDeviceNo. ofverticalmodulesMountingplateCut-outfront plateUpstreamfront plateLongterminalshieldsFixed Vigicompact NSVigi NS100/250 6 03033 03238 03802 29323 (3P)29324 (4P)Maximum size of connection cables: 95 mm².With cable duct: direct connection to the deviceCabletying08867DeviceNo. of verticalmodulesMountingplateCut-outfront plateLong terminalshields (set of 2)Fixed Compact NS and Vigicompact NSNS100/250 4 03030 03230 29323 (3P)29324 (4P)NS100/250 4 03033 03236 29323 (3P)with ammeter module29324 (4P)Vigi NS100/250 4 03033 03238 29323 (3P)29324 (4P)Compact NS, plug-inNS100/250 4 03032 03233 29332 (3P)29333 (4P)Direct connection to the Compact circuit breaker.DD380587DistributionPolyblocDevicePolybloc 250 ACompact NS, Vigicompact NS, Fixed Compact NS and Vigicompact NSNS100/250 3P 040334P 04034Vigi NS100/250 3P 040334P 04034Compact NS, plug-inNS100/250 3P 040334P 04034DD380522Distribution using Polybloc (04034).Distribution via Powerclip insulated busbars and NS250 powersupply block (04060).Powerclip insulated busbarsDevice Power supply block Terminal shieldsPowerclip busbars(set of 2)Fixed Compact NS and Vigicompact NSNS100/250 04060 see page 99NS100/250 with 04060 29321 (3P) see page 99ammeter module29322 (4P)Vigi NS100/250 04060 29321 (3P) see page 9929322 (4P)Compact NS, plug-in (1)NS100/25004060 + connection 29332 (3P) see page 99must be made 29333 (4P)(1) Two additional modules are required; add a lower plain front plate (03802).Other distribution solutionsDD380777DD380761Rear busbars,see page 100.Busbars in a duct,see page 102.34


DD380592Functional unitsSystem GCatalogue numbersInstallationCompact NS100/250VerticalFixedToggleDeviceNo. ofdevicesper rowNo. ofvert.mod.(1)MountingplateCut-outfrontplateUpstreamfront plateDownstreamfront plateLongterminalshields(set of 2)Fixed Compact NS and Vigicompact NSNS100/160 14 x 3P, 3 x 4P7 03040 03243 03802 29323 (3P)29324 (4P)NS250 14 x 3P, 3 x 4P9 03040 03243 03802 03802 29323 (3P)29324 (4P)VigiNS100/16014 x 3P, 3 x 4P8 03040 03241 03801 29323 (3P)29324 (4P)Vigi NS250 14 x 3P, 3 x 4P11 03040 03241 03802 03802 29323 (3P)29324 (4P)(1) With or without spreaders, whatever the distribution solution (Powerclip insulated busbars,Polybloc distribution block, etc.).DD380666DD381339AccessoriesBlanking plate for vertical NS100/250 (03249): see page 128.DD380780DistributionPolyblocDevice Polybloc 250 A Modular rail(adjustable)Fixed Compact NS and Vigicompact NSNS100/250 3P 04033 030024P 04034 03002Vigi NS100/250 3P 04033 030024P 04034 03002Distribution using a Polybloc distribution block (04034)on an adjustable modular device rail (03002).DD380593Powerclip insulated busbarsDeviceUniv. power +Short Powerclip busbarssupply block(w/oconnection)connection terminalshields(set of 2)Fixed Compact NS and Vigicompact NS (1 device centred on mounting plate)NS100/250 04061 + 04062 29321 (3P)29322 (4P)see page 99Vigi NS100/250 04061 mustbe made29321 (3P)29322 (4P)see page 99Distribution via Powerclip insulated busbars and a 250 Auniversal power supply block (04061) (without connection)+ connection (04062).DD380777Other distribution solutionsDD380761Rear busbars,see page 100.Busbars in a duct,see page 102.35


DD380594Functional unitsSystem GCatalogue numbersInstallationCompact NS100/250Horizontal, fixedDirect rotary handle or motormechanismWithout cable ductDeviceNo. of Mounting Cut-out Upstreamverticalmodules (1)plate front plate front plateFixed Compact NS and Vigicompact NSNS100/250Dir. rotary handleNS100/250Motor mech.Vigi NS100/250Dir. rotary handleDownstreamfront plateLongterminalshields8 03031 03232 03802 03802 29323 (3P)29324 (4P)8 03032 03234 03802 03802 29323 (3P)29324 (4P)8 03031 03237 +29285(collar)(1) Distribution using Polybloc.Size reduced two modules, lower front plate (03802) not needed.03802 03802 29323 (3P)29324 (4P)DD380589With cable ductDeviceNo. of Mounting Cut-out Downstream Long terminal shieldsverticalmodules (1)plate front plate front plateFixed Compact NS and Vigicompact NSNS100/250Dir. rotary handleNS100/250Motor mech.Vigi NS100/250Dir. rotary handle6 03031 03232 03802 29323 (3P)29324 (4P)6 03032 03234 03802 29323 (3P)29324 (4P)6 03031 03237 + 03802 29323 (3P)2928529324 (4P)(collar)(1) Distribution using Polybloc.Size reduced two modules, lower front plate (03802) not needed.DD380590DistributionPolyblocDevicePolybloc 250 AFixed Compact NS and Vigicompact NSNS100/250 3P 040334P 04034Vigi NS100/250 3P 040334P 04034Distribution using Polybloc (04034).DD380591Powerclip insulated busbarsDeviceUniv. power supplyblock(w/o connection)Short terminal shields(set of 2)Fixed Compact NS and Vigicompact NSNS100/250 04061 29321 (3P)29322 (4P)Vigi NS100/250 04061 29321 (3P)29322 (4P)Powerclip busbarssee page 99see page 99Distribution via Powerclip insulated busbars and a 250 Auniversal power supply block (04061) (supplied withoutconnection).DD380777Other distribution solutionsDD380761DD380761Rear busbars,see page 100.Busbars in a duct,see page 102.36


DD380595Functional unitsSystem GCatalogue numbersInstallationCompact NS100/250VerticalFixedDirect rotary handleDevice No. ofdevicesper rowNo. ofvert.mod. (1)MountingplateCut-outfrontplateFixed Compact NS and Vigicompact NSNS100/ 1160 4 x 3P, 3 x 4PNS250 14 x 3P, 3 x 4PVigiNS100/160VigiNS25014 x 3P, 3 x 4P14 x 3P, 3 x 4PUpstreamfront plateDownstreamfront plateLongterminalshields7 03041 03243 03802 29323 (3P)29324 (4P)9 03041 03243 03802 03802 29323 (3P)29324 (4P)8 03041 03244 +03801 29323 (3P)2928529324 (4P)(collar)11 03041 03244 +29285(collar)03802 03802 29323 (3P)29324 (4P)(1) With or without spreaders,whatever the distribution solution (Powerclip insulated busbars,Polybloc distribution block, etc.).AccessoriesDD380788DD381339Blanking plate for vertical NS100/250 (03249): see page 128.DD380596DistributionPolyblocDevicePolybloc250 AModular rail(adjustable)Fixed Compact NS and Vigicompact NSNS100/250 3P 04033 030024P 04034 03002Vigi NS100/250 3P 04033 030024P 04034 03002Distribution using a Polybloc distribution block (04034) on anadjustable modular device rail (03002).DD382304Powerclip insulated busbarsDevice Univ. power connection Short terminal Powerclip busbarssupply block(w/o connection)shields (set of 2)Fixed Compact NS and Vigicompact NS (1 device centred on mounting plate)NS100/250 04061 + 04062 29321 (3P)29322 (4P)see page 99VigiNS100/25004061 must be made 29321 (3P)29322 (4P)see page 99Distribution via Powerclip insulated busbars and a 250 Auniversal power supply block (04061) (supplied withoutconnection) + connection (04062).DD380777Other distribution solutionsDD380761Rear busbars,see page 100.Busbars in a duct,see page 102.37


Functional unitsSystem GInterpact INS-INV250/630HorizontalDirect front handleCatalogue numbersDD380669InstallationWithout cable duct: with connection blockDeviceNo. ofverticalmodulesMountingplateCut-out frontplateUpstreamfront plateConnection blockcables viatopcablesvia bottomInterpact INS-INVINS-INV250 5 03030 03231 03801 04066 or 04067Interpact INS-INV250 with incoming connection block (04066).DD380670With cable duct: direct connection to the deviceDeviceNo. ofverticalmodulesMountingplateCut-out frontplateUpstreamfront plateLong terminalshields(set of 2)Interpact INS-INVINS-INV250 4 03030 03231 29324INS-INV320/630 9 03070 03271 03803 32565cables via topINS-INV320/630cables via bottom6 03070 03271 32565Direct connection to Interpact INS-INV250.DD381346DistributionPolyblocDevice Polybloc250 AInterpact INS-INVINS-INV250 3P 040334P 04034Distribution using Polybloc (4P).DD381349Powerclip insulated busbarsDevice Power supply block Powerclip busbarsInterpact INS-INVINS-INV250 04060 see page 99INS-INV320/400 04070 see page 99INS-INV500/630 04071 see page 99Other distribution solutionsDD380777DD380761Distribution via Powerclip insulated busbars and NS250 powersupply block (04060).Rear busbars,see page 100.Multi-stage busbars,see page 102.38


DD380671Functional unitsSystem GCatalogue numbersInstallationInterpact INS-INV250/630VerticalDirect front handleLateral handleDeviceNo. of Mounting Cut-outverticalmodules (1)plate front plateUpstream Downstreamfront plate front plateLongterminalshield(set of 2)Interpact INS-INVINS-INV250 front 8 03040 03248 03801 03802 29324handleINS-INV250 lateral 8 03032 03806 03802 29324handleINS-INV320/400 front 10 03073 03274 32565handleINS-INV500/630 front 12 03073 03274 03802 32565handle(1) With or without spreaders.DD381347DistributionPolyblocDevice Polybloc Modular rail250 A adjustableInterpact INS-INVINS-INV250front handleINS-INV250lateral handle04037: copper spacer.3P 04033 030024P 04034 030023P 04033 + 04037 030034P 04034 + 04037 03003Distribution using a Polybloc distribution block (04034) on anadjustable modular device rail (03002).DD381348Powerclip insulated busbarsDevicePower supplyblock(w/oconnection)+ connection Short terminalshield(set of 2)Powerclip busbarsInterpact INS-INVINS-INV250 04061 + 04062 29322 see page 99INS-INV320/630 04074 must be made 32563 see page 99Distribution via Powerclip insulated busbars and a 250 Auniversal power supply block (04061) (without connection) +connection (04062).Other distribution solutionsDD380777DD380761Rear busbars,see page 100.Multi-stage busbars,see page 102.28 April 200439


esetOOFFONIFunctional unitsSystem GCatalogue numbersManual source changeoversystemFixed NS100/250, front connectionDirect rotary handleDD380535Source changeover system withmechanical interlockingDevice No. ofverticalmodulesMountingplateCut-out frontplateUpstreamfront plateDownstreamfront plateCompact NS with direct rotary handleNS100/250 10 03043 03245 03802 03803ODesignation Cat. no.Interlock 29369Coupling accessory 29358 (for 3P device)29359 (for 4P device)Long terminalshields (set of 2)29323 (3P)29324 (4P)40


IDD380536Functional unitsSystem GCatalogue numbersSource changeover system withmechanical interlockingManual source changeoversystemINS-INV250Front direct rotary handleDevice No. ofverticalmodulesMountingplateCut-outfront plateUpstreamfront plateDownstreamfront plateSource changeover system with mechanical interlockingINS-INV250changeover system9 03043 +31064 x 203235 03802 03802OFFOON II ONDesignationCat. no.Mechanical interlock 31073Coupling accessory 29358 (for 3P device)29359 (for 4P device)Long terminal shields 29324(set of 2)DD380537Complete source changeoverassemblyDevice No. ofverticalmodulesMountingplateComplete source changeover assemblyINS-INV250changeover systemCut-out frontplateUpstreamfront plateDownstreamfront plate9 03043 03247 03802 03802Designation Rating For 3PdeviceFor 4PdeviceComplete source 100 A 31140 31141changeover assembly160 A 31144 31145200 A 31142 31143250 A 31146 31147DesignationCoupling accessoryLong terminal shields(set of 2)Cat. no.29358 (for 3P device)29359 (for 4P device)2932441


Functional unitsSystem GFupact INFHorizontalDirect front rotary handleCatalogue numbersDD382474InstallationDeviceNo. ofdevicesper rowNo. ofverticalmodulesSwitch-disconnector fusesMountingplateCut-outfrontplateDownstreamfront plateLong terminalshields (qtyper device)INF32/40 3/4P 3 03113 03313INF63 3P 5 03114 03314 496584P 5 03114 03314 49658 x 2INF100/160 (1) 3P 7 03114 03314 03802 49659 x 64P 7 03114 03314 03802 49659 x 8(1) For direct distribution, downstream front plate (03802) not needed.INF32/40.DD382475INF100/160.DD382476DistributionMulti-stage busbars in a ductDevice Connection Multi-stage busbarsSwitch-disconnector fusesINF32/40 must be made see page 102INF63must be madeINF100/160 must be made42


Functional unitsSystem GFupact INFVerticalDirect front rotary handleCatalogue numbersDD382477InstallationINF32/40.DeviceNo. ofdevicesper rowNo. ofverticalmodulesSwitch-disconnector fusesMountingplateCut-outfrontplateDownstreamfront plateLong terminalshields (qtyper device)INF32/40 4 x 3P 3 03113 033123 x 4P 3 03113 03313INF63 3 x 3P 5 03114 03314 496582 x 4P 5 03114 03315 49658 x 2INF100/160 (1) 2 x 3P 7 03114 03315 03802 49659 x 62 x 4P 7 03114 03315 03802 49659 x 8(1) For direct distribution, downstream front plate (03802) not needed.DD382478INF100/160.DD382479DistributionPolybloc distribution blockDevice Polybloc Adjustable modular device railSwitch-disconnector fusesINF100/160 3P 04033 030024P 04034 03002Other distribution solutionsDD380761Multi-stage busbars in a duct,see page 102.43


PD390542Functional unitsSystem GCatalogue numbersPresentationModular devicesNG125 circuit breakersNSA125/160 circuit breakersINS40/160 switch-disconnectorsGeneralA rigid modular railMade using an aluminium alloy, the rail design is extremely rigid. The rail supportsare crimp mounted.Fast mountingThe pre-mounted rail supports have positioning studs to guide the rail at the rear ofthe enclosure.Only two mounting screws are required.Multiple functionsA number of devices clip directly onto the rear of the rails, including 80 A and 200 AMulticlip distribution blocks, all horizontal cable-running accessories such as cablestraps and trunking supports, as well as the supports for earth bars.Supply from all directionsSupply to the rows, using comb busbars or Multiclip distribution blocks, can be via:b a Polybloc distribution block installed on the incoming deviceb Powerclip insulated busbars installed behind the devicesb multi-stage busbars installed in a lateral ductb flat busbars installed at the rear of the enclosure.PD390543Distribution using Powerclip busbars:see page 99.Distribution using Distribloc in a Pack wall-mount enclosure:see page 108.Distribution blocksMulticlip distribution blocksFast and secure front connection using spring terminals.Particularly reliable connections, will not loosen over time, insensitive to vibrationsand thermal variations.All types of modular devices can be mixed.Easy balancing of phases.Interchangeable devices.Easy installation upgrades.Fully insulated.Comb busbarsDirect connection to device terminals or via a connector.Fully insulated.Can be cut to length.Cable runningCable strapsEasy and fast to install.Low cost.TrunkingPerfectly integrated cable running.Attractive.44


DD380678Functional unitsSystem GCatalogue numbersMulti 9 devicesModular devicesNG125 circuit breakersNSA125/160 circuit breakersINS40/160 switch-disconnectorsDeviceNo. of verticalmodulesModular railModular frontplateAll Multi 9 devicesAll supply systems (comb busbars, 4 03001 03204Multiclip) with cable straps and trunkingsectionsMulti 9 devices y 40 ASupply via 63/80 A Multiclip or comb 3 03001 03203busbars with cable strapsCapacity of modular rail: 48 Multi 9 modules.Note: For a modular row with a 160 A (half row) and 200 A Multiclip distribution block positioneddirectly below a non-modular mounting plate (Compact, Interpact, etc.), or at the top of aswitchboard, add one vertical module (i.e. 4 + 1) and a plain upstream front plate (03801).DD382417Supply: 80 A Multiclip.Cable running: cable straps.Mounting requires 3 vertical modules.NG125 circuit breakerDevice No. of verticalmodulesModular railModular frontplateNG125 circuit breakerNG125, Vigi NG125 5 03001 03205Direct supply via cables.Capacity of modular rail: 48 Multi 9 modules.Width of NG125 circuit breakers: NG125 3P : 9 Multi 9 modulesNG125 4P : 12 Multi 9 modulesVigi NG125 3P : 18 Multi 9 modulesVigi NG125 4P : 21 Multi 9 modulesDD380686NSA125/160 circuit breakerDeviceNo. of verticalmodulesModular rail(adjustable)Modular frontplateNSA125/160 circuit breakerNSA125/1605 03002 03205Vigi NSA125/160Direct supply via cables.Capacity of modular rail: 48 Multi 9 modules.Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device)the symmetrical rail + raiser set(28041).Width of devices: NSA125/160 3P: 10 Multi 9 modulesNSA125/160 4P: 14 Multi 9 modulesVigi NSA125/160 3P: 24 Multi 9 modulesVigi NSA125/160 4P: 27 Multi 9 modulesDD380685INS switch-disconnectorDeviceNo. of verticalmodulesModular railModular frontplateINS40/160INS40/160 4 03001 03204INS100/1605 03001 03205with long terminal shieldsDirect supply via cables.Capacity of modular rail: 48 Multi 9 modules.Width of devices: INS40/80: width 10 Multi 9 modulesINS100/160: width 15 Multi 9 modules45


Functional unitsSystem GCatalogue numbersPowerclip insulated busbarsModular devicesNG125 circuit breakersNSA125/160 circuit breakersINS40/160 switch-disconnectorsBusbar selectionsee page 99.DD381212DD380679DD380674Tap-off blocks for insulated busbars (04151).Supply to a 200 A Multiclip distribution block(04021).DD381610Connection 04145.Cover for connection04150.Rear busbarsBusbar selectionsee page 100.DD381213DD381214DD381215200 A Multiclip connection (04029). 125 A connection to a comb busbar (04145).Busbars in a ductBusbar selectionsee page 102.DD381216DD381397Supply to a 200 A Multiclip distribution block(04024).46


DD381308Functional unitsSystem GCatalogue numbersDistribloc distribution blockModular devicesNG125 circuit breakersNSA125/160 circuit breakersINS40/160 switch-disconnectorsDesignationCat. no.125 A Distribloc distribution block 04045160 A Distribloc distribution block 04046see page 108DD380675Multiclip distribution blocksDesignationCat. no.Multiclip, 80 A, 4P 04004Multiclip, 63 A, 4P, 1/2 row 04008Multiclip, 200 A, 2P 04012Multiclip, 200 A, 3P 04013Multiclip, 200 A, 4P 04014Multiclip, 160 A, 4P, 1/2 row 04018Connection between 200 A Multiclip and Powerclip insulated busbars 04021see page 114DD380755Comb busbarsFor C60 circuit breakersDesignationCat. no.1P 24-module comb busbar (9 mm modules) 14481Two 48-module comb busbars (9 mm modules) 148912P 24-module comb busbar (9 mm modules) 14482Two 48-module comb busbars (9 mm modules) 148923P 24-module comb busbar (9 mm modules) 14483Two 48-module comb busbars (9 mm modules) 148934P 24-module comb busbar (9 mm modules) 14484Two 48-module comb busbars (9 mm modules) 14894For C120 and NG125 circuit breakersDesignationCat. no.1P (W = 430 mm, 16 poles) 148112P (W = 430 mm, 16 poles) 148123P (W = 430 mm, 16 poles) 148134P (W = 430 mm, 16 poles) 14814Thoot caps (set of 20) 14818DD380812DD380805Cable runningBlanking platesDesignationCat. no.Cable straps12 vertical cable straps 042642 covers, 1-meter long, for vertical cable straps 0426312 horizontal cable straps 042394 covers, 430 mm long, for horizontal cable straps 04243Trunking4 horizontal sections, 60 x 30 mm, L = 450 mm 04257Vertical section, 80 x 60 mm, L = 2 m 0426712 horizontal trunking supports 0425512 vertical trunking supports 04265see page 126DesignationCat. no.Blanking strip, H = 46 mm, L = 1 m 032204 divisible blanking plates, H = 46 mm, L = 90 mm 03221see page 12847


Functional unitsSystem GIndustrial control devicesCatalogue numbersDD381613Series D and K contactorsDevice No. ofverticalmodulesUseful raillength (mm)Series D and K contactorsSeries D and Kcontactors y 40 ARear modularrail3 432 03004 03803Plain front plateDD381317GV2/GV3 circuit breakersDeviceNo. ofverticalmodulesUseful lengthof rail(mm)Modular railCut-out frontplateGV2/GV3 circuit breakersGV2 3 432 03001 03203GV3 5 432 03002 03205Width of devices without lateral auxiliaries: 45 mm.AccessoriesDD381426Modular blanking plates: see page 128.DD381318GV2 + contactor combinationDeviceNo. ofverticalmodulesUseful lengthof rail(mm)GV2 + contactor combinationGV2 + Series D orK contactor y 40 ARear modularrailTransparentfront platePlainfront plate5 432 03004 03342 03801Width of devices without lateral auxiliaries: 45 mm.DD381319TeSys U modelDeviceNo. ofverticalmodulesUseful lengthof rail(mm)Rear modularrailTransparentfront plateTeSys U modelTeSys U model 4 432 03004 03342Width of devices without lateral auxiliaries: 45 mm.48


Functional unitsSystem GIndustrial control devicesDD382601Catalogue numbersLH4 soft startersDeviceLH4 soft startersLH4 N1LH4 N2Width of devices:LH4 N1: 45 mm.LH4 N2: 90 mm.No. of verticalmodulesUseful lengthof rail(mm)Rearmodular railPlain frontplate4 432 03004 03804DD382602Tego PowerDeviceTego PowerTego Power 2 to 8feedersNo. of verticalmodulesMountingplateTransparentfront plateUpstreamfront plateDownstreamfront plate8 03168 03343 03801 03801DD382603ATS01 soft startersDeviceNo. of verticalmodulesUseful lengthof rail(mm)Modular railPlain frontplateModular railATS01N103/106FT 4 432 03004 03804ATS01N109/112FT 5 432 03003 03805ATS01N206 to 212 5 432 03003 03805ATS01N222 to 232 6 432 03003 03806ATS01N230LY 5 432 03003 03805ATS01N244LY 5 432 03003 03805ATS01N244Q 5 432 03003 03805DD382604No. of verticalmodulesRecessed slottedmounting platePlainfront plateSlotted mounting plateATS012N272LY 6 03172 03806ATS012N285LY 6 03172 03806ATS012N272Q 6 03172 03806ATS012N285Q 6 03172 03806Width of devices:ATS01N103/106FT: 22,5 mmATS01N109/112FT: 45 mmATS01N206 to 212: 45 mmATS01N222 to 232: 45 mmATS01N230LY: 180 mmATS01N244LY: 180 mmATS01N244Q: 180 mmATS012N272LY: 180 mmATS012N285LY: 180 mmATS012N272Q: 180 mmATS012N285Q: 180 mmDD382605<strong>LV</strong>/<strong>LV</strong> transformerDeviceNo. of verticalmodulesRecessed slottedmounting platePlainfront plate<strong>LV</strong>/<strong>LV</strong> transformerABL6-TS/TD up to 4 03171 03804630 VAABL6-RF up to 120 W 4 03171 0380449


6040100604010060401006040100604010060401006040100604010060401006040100604010060401006040100404040Functional unitsSystem GHuman-switchboard interfaceCatalogue numbersDD381705DD381684Measurement devices with interfaceand plastic mounting platesFront plate with cut-outs, four mounting plates and one plainmounting plate for 72 x 72 mm devices.AAAAPresentationThe interface for 72 x 72 and 96 x 96 mm measurement devices is made up of:b a special front plate with cut-outs (03904) for plastic mounting platesb plastic mounting plates for the 72 x 72 or 96 x 96 mm devices.The front plate can be equipped with:b five mounting plates with cut-outs for 72 x 72 mm devicesb four mounting plates with cut-outs for 96 x 96 mm devices.It can also be equipped with plain plastic mounting plates to blank off any unusedpositions. The plain mounting plates can be easily cut out for lamps, pushbuttons or72 x 72 mm devices.Each mounting plate has a cable-running system for auxiliary wires and can beidentified by a label.InstallationThe interface for 72 x 72 and 96 x 96 mm devices is installed similar to a front plate:b in the device zone of enclosuresb on a partial door with cut-outs in wall-mount and floor-standing enclosures(except IP55).The degree of protection for installed devices is IP30.Cat. no. selectionDesignationCat. no.Front plate (3 modules) for five 72 x 72 mm or four 96 x 96 mm devices 03904Mounting plate for 72 x 72 mm with cut-outs 03902deviceplain 03900Mounting plate for 96 x 96 mmdevicewith cut-outs 03903plain 03901Doors with cut-outs for the measurement-device interfaceMounting on a cubicle door cut-out (System P).Partial door6 modulesIP30/31/43 enclosures (08851) see page 78DD381685DD381687DD381688AAAAThe mounting plates have guides for auxiliarywires.Mounting plates can be identified by a label(not supplied).Note: For degree of protection IP55, devices must be installed behind a transparent door. If theyare installed on the door, use the mounting plates intended for IP55 enclosures (see page 86).Mounting in the device zone of an enclosure (System G).DD380862AAAAVisor for measurement devicesPresentationThe interface with the plastic mounting plates for 72 x 72 mm and 96 x 96 mmdevices can be mounted on a visor.The visor can be installed on 300 and 400 mm wide doors with cut-outs in cubiclesor on partial doors in wall-mount and floor-standing enclosures.It is supplied with a drilling diagram for mounting on a plain door.Cat. no. selectionDesignationCat. no.Visor for measurement devices 03928DD381686AVisor mounted on a cubicle door cut-out.100A 60100A 60A 60100Visor mounted on the partial door of an enclosure.50


Functional unitsSystem GHuman-switchboard interfaceCatalogue numbersDD381689Measurement devices on a metalfront plateInstallationThe 72 x 72 mm or 96 x 96 mm measurement devices are installed directly on a frontplate with cut-outs, H = 150 mm (3 modules):b in the device zone of enclosuresb on a partial door with cut-outs in wall-mount and floor-standing enclosures (exceptIP55).The degree of protection for installed devices is IP30.Unused positions are blanked off using blanking plates.Device No. of vertical modules Cut-out frontplateMeasurement deviceSix 72 x 72 mm measurement devices 3 03910Four 96 x 96 mm measurement devices 3 03911One 144 x 144 mm device + four 72 x 72 devices 4 0391203910.DD381711Accessories72 x 72 mm blanking plate 0390796 x 96 mm blanking plate 03908Blanking plates have knock-outs for 22 mm lamps or pushbuttons.03911.DD381712DD38169103912.DD381690Pushbuttons or lampsInstallation in the device zone on a metal front plate with cut-outs.Device No. of vertical modules Cut-out frontplatePushbuttons12 pushbuttons or lamps (22 mm diameter) 2 0391403914.51


MERLIN GERINVigirexRH10MTestTest no tripFunctional unitsSystem GHuman-switchboard interfaceCatalogue numbersDD382536Powerlogic systemDevice No. of vertical modules Cut-out front platePowerMeter PMPower Meter PM700/500/800(96 x 96 mm case)3 03911Installation in the device compartment.DD382535VigilohmDeviceNo. of verticalmodulesModular railCut-out frontplateVigilohmTR22A/AH (1 TR + 6 measurement 5 03934devices, 72 x 72 mm)EM9, TR5A, SM21 (modular devices) 3 03001 03203Installation in the device compartment.03934.DD381700VigirexReset onfaultDeviceNo. of verticalmodulesModular railCut-out frontplateVigirexRH10/RH21/RH99 relaysModular device 3 03001 0320372 x 72 mm cases see page 50RHU relay (72 x 72 mm cases) see page 50RMH relay and RM12T multiplexerRMH (modular devices) 3 03001 03203RM12T (72 x 72 mm cases see page 50Installation in the device compartment.52


2 3A452 3A45Functional unitsSystem GHuman-switchboard interfaceCatalogue numbersDD381701Multi 9 measurement deviceDeviceNo. of verticalmodulesModular railCut-out frontplateMulti 9 measurement deviceLamps, pushbuttons, etc. 2 03001 03202Ammeter, voltmeter, etc. 3 03001 03203Installation in the device compartment.DD381756Cable runningDesignationCat. no.Cable trunking for doors, L = 2000 mm 04233Flexible trunking for wiring to door 04235Terminal block for auxiliaries 0422810 grommets for wiring through front 04234DD381641DD381643Auxiliary wiring on partial door with cut-outs. Trunking for a door. Flexible trunking to protect and guide wires.DD381644DD381755Terminal block for auxiliaries.Grommets.53


Functional unitsSystem GOther devicesOn a modular railOn a slotted plateCatalogue numbersDD381351Installation on a modular railDesignationDepth behind frontplate (mm)Useful length(mm)Cat. no.Modular railModular rail (adjustable) 47 to 114 432 03002Recessed modular rail 158 432 03003Rear modular rail 128 432 03004Modular rail, with 4 holes,dia. 6.4 mm, 450 mm betweencentres1600 04226DD381352Modular rail (adjustable) (03002).DD381355Plain and transparent front plates:see page 56.Recessed modular device rail (03003).DD381353Rear modular rail (03004).DD381310Modular rail, L = 1600 mm (04226).DD381356Installation on a slotted plateDesignationNo. ofverticalmodulesSlotted mounting plateFlat slotted mountingplateRecessed slottedmounting plateUsefulheight(mm)Usefulwidth(mm)Depth behindfront plateCat. no.4 200 440 140 031704 200 420 160 031716 300 420 160 031729 450 450 160 03173Flat slotted mounting plate (03170).DD381355DD381357Plain and transparent front plates:see page 56.Recessed slotted mounting plate (03171).54


Functional unitsSystem GOther devicesAccessoriesCatalogue numbersDD382594Clip-nuts for slotted mountingplatesThese nuts are used to install various devices (contactors, transformers) on a slottedmounting plate.They can also be installed on the cable-tie supports in enclosures.DesignationCat. no.20 clip-nuts for slotted mounting platesM4 03180M5 03181M6 03182DD382595Clip-nuts for modular railsThese nuts are used to install various devices on a modular rail.DesignationCat. no.20 clip-nuts for modular railsM4 03164M5 03165M6 03166DD382596Clip-nuts for lateral andlongitudinal cross-membersThese nuts can be installed on the functional uprights in IP30/55 wall-mount andfloor-standing enclosures.DesignationCat. no.20 M6 captive nuts 03194DD382597Pratic raiser Colour RAL 9001.The raiser clips onto a slotted mounting plate or a modular rail.It is 27 mm wide and serves to raise a device 10 mm.It is made of an insulating material and can directly receive terminal blocks, modulardevices, etc.DesignationCat. no.5 Pratic raisers 04224DD382598M5 self-trapping screwsDesignationCat. no.20 M5 self-trapping screws for mounting on functional uprights 03183DD382599Hexagonal spacersDesignationCat. no.M5 hexagonal spacers4 spacers H = 9 mm 03185H = 23 mm 03186H = 55 mm 03187M6 hexagonal spacers4 spacers H = 9 mm 03195H = 23 mm 03196H = 25 mm 03198H = 55 mm 03197M8 hexagonal spacers4 spacers H = 40 + 10 mm 03199DD38260055


Functional unitsSystem GSwitchboard lightingReserve spaceCatalogue numbersDD381719Switchboard lightingThis system is generally used to illuminate the front of a switchboard.The kit is made up of:b a baseb a neon tubeb afront plate with cut-out (1 module)b a door contact.Characteristicsb supply voltage: 220/240 Vb power rating: 8 W.Cat. no. selectionDesignation No. of modules Cat. no.Switchboard lighting 1 08964Installation in a wall-mount or floor-standing enclosure(System G).DD381583Device compartment, W = 600 mm500 mm wide plain front plate Cat. no.1 module (H = 50 mm) 038012 modules (H = 100 mm) 038023 modules (H = 150 mm) 038034 modules (H = 200 mm) 038045 modules (H = 250 mm) 038056 modules (H = 300 mm) 038069 modules (H = 450 mm) 0380712 modules (H = 600 mm) 03808DD381582500 mm wide transparent front plate Cat. no.4 modules (H = 200 mm) 033426 modules (H = 300 mm) 033439 modules (H = 450 mm) 0334412 modules (H = 600 mm) 0334556


DD380744300 mm wide functionalunitsSystem GCatalogue numbersInstallationCompact NS100/630VerticalFixedToggle or direct rotary handleToggleDeviceNo. ofverticalmodules (1)MountingplateCut-out Upstreamfront plate front plateDownstreamfront plateLong terminalshieldsCompact NSNS100/250 9 03050 03250 29323 (3P)29324 (4P)NS400 11 03080 03280 03812 03811 32564 (3P)32565 (4P)NS630 12 03080 03280 03812 03812 32564 (3P)32565 (4P)Vigi Compact NSVigi NS100/250 11 03050 03252 29323 (3P)29324 (4P)Vigi NS400/630 14 03080 03282 03812 03812 32564 (3P)32565 (4P)(1) With or without spreaders.DD380743Direct rotary handleMounting plate Cut-out front plate Long terminalDevice No. ofmodules (1) (set of 2)verticalshieldsCompact NSNS100/250 9 03051 03253 29323 (3P)29324 (4P)NS400/630 12 03081 03283 32564 (3P)32565 (4P)(1) With or without spreaders.58


DD380745300 mm wide functionalunitsSystem GCatalogue numbersDistributionCompact NS100/630VerticalFixedToggle or direct rotary handlePolyblocDevice250 A Polybloc Modular rail (adjustable)Compact NS and Vigi Compact NSNS100/250 3P 04033 03011and Vigi 4P 04034 03011Distribution via a Polybloc distribution block (04034) on amodular device rail (03011).Powerclip insulated busbarsDevice Univ. power supplyblock (w/o conn.)+ connection Short terminalshields (set of 2)Compact NS and Vigi Compact NSNS100/250 04061 + 04064 29321 (3P)and Vigi29322 (4P)NS400/630and Vigi04074 + 04073 32562 (3P)32563 (4P)Powerclip busbarssee page 99Note: available space at top of enclosure after mounting the universal power supply block:NS100/630 = 7 modulesVigi NS100/630 = 9 modules.Space required for power supply block on Powerclip = 5 modules.DD382305Multi-stage busbarsDevice Connection Short terminal shields(set of 2)DesignationNS100/250and VigiNS400/630and Vigi04065 29321 (3P)29322 (4P)04075 32562 (3P)32563 (4P)Multi-stage busbarssee page 102.see page 102.Other distribution solutionsDD380777Rear busbars, see page 100.59


300 mm wide functionalunitsSystem GInterpact INS-INV250/630VerticalFront, direct rotary handleCatalogue numbersDD382568InstallationDeviceNo. ofverticalmodules (1)MountingplateCut-out Downstreamfront plate front plateLong terminalshieldsInterpact INS-INVINS-INV250 9 03050 03251 29324INS-INV320/400 10 03080 03281 32565INS-INV500/630 12 03080 03281 03812 32565(1) With or without spreaders.60


300 mm wide functionalunitsSystem GInterpact INS-INV250/630VerticalFront, direct rotary handleCatalogue numbersDD382569DistributionPolyblocDevicePolybloc250 AModular rail(adjustable)Interpact INS-INVINS-INV250 3P 04033 030114P 04034 03011Distribution via a Polybloc distribution block (04034) on anadjustable modular device rail (03011).DD382570Powerclip insulated busbarsDeviceUniv. powersupply block(w/o conn.)+ connection Short terminalshields(set of 2)Powerclip busbarsInterpact INS-INVINS-INV250 04061 + 04064 29322 see page 99INS-INV320/630 04074 + 04073 32563Note : available space at top of enclosure after mounting the universal power supply block:INS-INV250/630 = 7 modules.Space required for power supply block on Powerclip = 5 modules.Distribution via Powerclip insulated busbars and a 250 Auniversal power supply block (04061) (without connection) +connection (04064).DD382571Multi-stage busbarsDevice Connection Short terminal shields(set of 2)Multi-stage busbarsInterpact INS-INV switch-disconnectorINS-INV250 04065 29322 see page 102.INS-INV320/630 04075 32563 see page 102.Other distribution solutionsDD380777Rear busbars, see page 100.61


300 mm wide functionalunitsSystem GModular devicesNSA125/160 circuit breakersINS40/160 switch-disconnectorsCatalogue numbersDD380765Multi 9 devicesDeviceAll Multi 9 devicesAll supply systems with cable straps ortrunkingMulti 9 devices y 40 ANo. ofmodulesModular rail4 03010 03214Supply via 63 A Multiclip or comb 3 03010 03213busbars with cable strapsCapacity of modular rail: 20 Multi 9 modules.Modular front plateSupply via comb busbars.Width of NG125 circuit breakers:NG125 3P: 9 Multi 9 modulesNG125 4P: 12 Multi 9 modulesVigi NG125 3P: 18 Multi 9 modulesDD380764Supply via 63 A Multiclip.DD381367NSA125/160 circuit breakerDeviceNo. ofverticalmodulesModular rail(adjustable)Modularfront plateDownstreamfront plateNSA125/160 circuit breakerNSA125/160 5 03011 03214 03811Capacity of modular rail: 20 Multi 9 modules.Note: To mix an NSA125/160 circuit breaker with Multi 9 modular devices, order (with the device)the symmetrical rail + raiser set (28041).Width of devices:NSA125/160 3P: 10 Multi 9 modulesNSA125/160 4P: 14 Multi 9 modulesDD381368INS switch-disconnectorDeviceNo. ofmodulesModular railModularfront plateDownstreamfront plateINS160INS40/160 4 03010 03214INS100/1605 03010 03214 03811with long terminal shieldsCapacity of modular rail: 20 Multi 9 modules.Width of devices:INS40/80: width 10 Multi 9 modulesINS100/160: width 15 Multi 9 modules62


300 mm wide functionalunitsSystem GModular devicesNSA125/160 circuit breakersINS40/160 switch-disconnectorsCatalogue numbersPowerclip insulated busbars see page 99.DD381211Rear busbars see page 100.DD380813Multi-stage busbars see page 102.DD380816Distribloc distribution blocks see page 108.DD381308Multiclip distribution blocks see page 114.DD380817Comb busbars see page 47DD380820Cable running see page 126.DD380818Blanking plates see page 128.DD38080563


300 mm wide functionalunitsSystem GIndustrial control devicesCatalogue numbersDD380708Series D and K contactorsDevice No. ofverticalmodulesUseful raillength(mm)Series D and K contactorsSeries D and Kcontactors y 40 AModular rail(adjustable)3 180 03011 03813Plain front plateDD381188GV2/GV3 circuit breakersDevice No. ofverticalmodulesUseful raillength(mm)ModularrailCut-out frontplateUpstreamfrontplateDownstreamfront plateGV2/GV3 circuit breakersGV2 3 180 03010 03213GV3 5 180 03011 03213 03811 03811Width of devices without lateral auxiliaries: 45 mm.AccessoriesDD381426Modular blanking plates, see page 128DD381189GV2 + contactor combinationDevice No. of Useful rail Modular rail Transparent Plain front platevertical length (mm) (adjustable) front platemodulesGV2 + contactor combinationGV2 + Series D or K 5 180 03011 03352 03811contactor y 40 AWidth of devices without lateral auxiliaries: 45 mm.DD381190TeSys U modelDevice No. ofverticalmodulesUseful rail length (mm)Modular rail(adjustable)Transparentfront plateTeSys U modelTeSys U model 4 180 03011 03352Width of devices without lateral auxiliaries: 45 mm.64


300 mm wide functionalunitsSystem GIndustrial control devicesCatalogue numbersDD381191LH4 soft startersDevice No. of verticalmodulesLH4 soft startersLH4 N1LH4 N2Width of devices:LH4 N1: 45 mm LH4 N1: 45 mmLH4 N2: 90 mm.Useful rail length (mm)Modular rail Plain front(adjustable) plate4 180 03011 03814DD380709<strong>LV</strong>/<strong>LV</strong> transformerDevice No. of verticalmodules<strong>LV</strong>/<strong>LV</strong> transformerABL6up to 400 VASlotted mounting platePlain frontplate4 03175 03814Cable running and distributionMulticlip distribution blockssee page 114DDD380819Comb busbarssee the Telemecanique catalogue and see page 47DD380820Cable runningsee page 126DD38068865


300 mm wide functionalunitsSystem GOther devicesOn a modular railOn a slotted mounting plateCatalogue numbersDD381370Installation on a modular railDesignationCat. no.Modular railModular rail 03010Adjustable modular rail 03011Modular rail, L = 1600 mm04226with 4 holes, dia. 6.4 mm, 450 mm between centresDD381372DD381371Modular rail (03010). Adjustable modular rail (03011).DD381310DD382651Modular rail, L = 1600 mm (04226).Plain and transparent front plates, seepage 68.DD381374Installation on a slotted mountingplateDesignationNo. ofmodulesSlotted mounting plateFlat slotted mountingplateRecessed slottedmounting plateUseful Useful widthheight (mm) (mm)Depth behindfront plateCat. no.4 200 mm 172 140 031754 200 mm 172 160 031766 300 mm 172 160 031779 450 mm 172 160 03178DD381375DD381369Recessed slottedmounting plate.Flat slotted mounting plate.66


Functional unitsSystem GFixing accessoriesCatalogue numbersDD382594Clip-nuts for slotted mountingplatesThese nuts are used to install various devices (contactors, transformers) on a slottedmounting plate.They can also be installed on the cable-tie supports in enclosures.DesignationCat. no.20 clip-nuts for slotted mounting platesM4 03180M5 03181M6 03182DD382595Clip-nuts for modular railsThese nuts are used to install various devices on a modular rail.DesignationCat. no.20 clip-nuts for modular railsM4 03164M5 03165M6 03166DD382596Clip-nuts for lateral andlongitudinal cross-membersThese nuts can be installed on the functional uprights in IP30/55 wall-mount andfloor-standing enclosures.DesignationCat. no.20 M6 captive nuts 03194DD382597Pratic raiser Colour RAL 9001.The raiser clips onto a slotted mounting plate or a modular rail.It is 27 mm wide and serves to raise a device 10 mm.It is made of an insulating material and can directly receive terminal blocks, modulardevices, etc.DesignationCat. no.5 Pratic raisers 04224DD382598M5 self-trapping screwsDesignationCat. no.20 M5 self-trapping screws for mounting on functional uprights 03183DD382599Hexagonal spacersDesignationCat. no.M5 hexagonal spacers4 spacers H = 9 mm 03185H = 23 mm 03186H = 55 mm 03187M6 hexagonal spacers4 spacers H = 9 mm 03195H = 23 mm 03196H = 25 mm 03198H = 55 mm 03197M8 hexagonal spacers4 spacers H = 40 + 10 mm 03199DD38260067


Functional unitsSystem GSwitchboard lightingReserve spaceCatalogue numbersDD381719Switchboard lightingThis system is generally used to illuminate the front of a switchboard.The kit is made up of:b a baseb a neon tubeb afront plate with cut-out (1 module)b a door contact.Characteristicsb supply voltage: 220/240 Vb power rating: 8 W.Cat. no. selectionDesignation No. of modules Cat. no.Switchboard lighting 1 08964Installation in a wall-mount or floor-standing enclosure(System G).DD381583Device compartment, W = 600 mm500 mm wide plain front plate Cat. no.1 module (H = 50 mm) 038012 modules (H = 100 mm) 038023 modules (H = 150 mm) 038034 modules (H = 200 mm) 038045 modules (H = 250 mm) 038056 modules (H = 300 mm) 038069 modules (H = 450 mm) 0380712 modules (H = 600 mm) 03808DD381582500 mm wide transparent front plate Cat. no.4 modules (H = 200 mm) 033426 modules (H = 300 mm) 033439 modules (H = 450 mm) 0334412 modules (H = 600 mm) 0334556


EnclosuresSystem GIP30/IP31/IP43 wall-mountenclosuresPresentationCatalogue numbersCarefully designed in every detail,<strong>Prisma</strong> <strong>Plus</strong> wall-mount enclosures arethe solution for all common switchboardconfigurations up to 630 A:b a wide range with eight heights from 330to 1380 mm, in 50 mm stepsb two widths:v 595 mm for devicesv 305 mm for cables, terminal blocks,busbars or devicesb can be combined side-by-side and one ontop of anotherb a standard degree of protection IP30 (withor without a door) that can be upgraded toIP43b a structure designed to facilitate fast andtotal access at all times to the devices andall the connection points in the switchboardb a discreet appearance that blends well incommercial settings, including entry halls orpassagewaysb colour RAL9001.<strong>Prisma</strong> <strong>Plus</strong> wall-mount enclosures complywith standard EN 50298.PD390463Combination of a wall-mount enclosure with a 300 mm wide duct.PD390554The entire front can be removed for fast, direct access to all the devices.70


EnclosuresSystem GIP30/IP31/IP43 wall-mountenclosuresPresentationCatalogue numbersCarefully designed in every detail,<strong>Prisma</strong> <strong>Plus</strong> floor-standing enclosures arethe solution for all common switchboardconfigurations up to 630 A:b three heights from 1530 to 1830 mm,including a 150 mm plinthb two widths:v 595 mm for devicesv 305 mm for cables, terminal blocks,busbars or devicesb side-by-side combinationsb a standard degree of protection IP30 (withor without a door) that can be upgraded toIP43b a structure designed to facilitate fast andtotal access at all times to the devices andall the connection points in the switchboardb a discreet appearance that blends well incommercial settings, including entry halls orpassageways<strong>Prisma</strong> <strong>Plus</strong> floor-standing enclosurescomply with standard EN 50298.PD390476Combination of a basic floor-standing enclosure with a 300 mm wide duct.71


EnclosuresSystem GIP30/IP31/IP43 floor-standingenclosuresPresentationCatalogue numbersPD390555PD390553The sides slip naturally into place with the helpof the positioning guides.The enclosures are easily mounted on the wallusing a practical system based on a hingedfork.PD390556PD390561Only four screws are required to secure thecover panels.The front of the plinth can be removed tofacilitate spreading of cables and fixing to thefloor (floor-standing enclosures).72


EnclosuresSystem GIP30/IP31/IP43 floor-standingenclosuresPresentationCatalogue numbersPD390559PD390560The comfortable handles drive the door locking bolts. They are equipped with keylocks (405keys) and can be fitted with other locks or inserts.PD390552PD390557The structure is made up of a rigid rear panelwith four screw-on, metal, corner struts (wallmountenclosures).Wall-mount enclosures and the 300 mm wideducts can be easily combined using metalgussets (wall-mount enclosures).73


EnclosuresSystem GIP30/IP31/IP43 wall-mountenclosuresCatalogue numbersDD380618Wall-mount enclosure (IP30)DD380622DD380623DD380624No. of verticalmodulesHeight ofenclosureEnclosure Plain door TransparentdoorWall-mount enclosure (IP30)6 330 08102 08122 081329 480 08103 08123 0813312 630 08104 08124 0813415 780 08105 08125 0813518 930 08106 08126 0813621 1080 08107 08127 0813724 1230 08108 08128 0813827 1380 08109 08222 08232b reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 82.DD380598Duct, W = 300 mm (IP30)DD380625DD380626DD380627No. of verticalmodulesDuct (IP30)Height of ductDuct,W=300mmPlain doorTransparentdoor6 330 08172 081829 480 08173 0818312 630 08174 0818415 780 08175 0818518 930 08176 0818621 1080 08177 08187 0819724 1230 08178 08188 0819827 1380 08179 08282 08292b the duct is supplied with a combination kit for the enclosureb reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 82.DD381258Duct front plate, see page 68.DD381257Canopy (IP31)The addition of a canopy over the wall-mount enclosure (and the duct) equipped witha door ensures compliance with the degree of protection IP31 (see page 78).Gasket (IP43)When the wall-mount enclosure (and the duct) is equipped with a canopy, a gasketfor the door of the wall-mount enclosure (and the duct) ensures compliance withthe degree of protection IP43 (see page 78).74


EnclosuresSystem GIP30/IP31/IP43 wall-mountenclosuresCatalogue numbersDD381259Side-by-side combinationEnclosure + 300 mm wide ductThe combination kit (two combination brackets) is supplied with the duct.To make the combination more rigid, particularly during transport, it is advised to usea set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationSet of two lifting/reinforcement cross-members for single wall-mountenclosure and 300 mm wide ductCat. no.08812DD381260Enclosure + enclosureA combination kit (must be ordered) ensures the mechanical connection between thetwo wall-mount enclosures.To make the combination more rigid, particularly during transport, it is mandatory touse a set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationCat. no.Combination kit 08816Set of two lifting/reinforcement cross-members for two wall-mount enclosures 08811DD381261Enclosure + 300 mm wide duct + enclosureA combination kit is supplied with the duct. Only one additional combination kit mustbe ordered for the mechanical connection between the two wall-mount enclosuresand the duct.To make the combination more rigid, particularly during transport, it is mandatory touse a set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationCat. no.Combination kit 08816Set to two lifting/reinforcement cross-members for two wall-mount enclosures 08813and a ductDD381262Vertical combinationA combination kit (must be ordered) ensures the mechanical connection between thetwo wall-mount enclosures.To make the combination more rigid, particularly during transport, it is mandatory touse a set of combination uprights secured to the rear of the switchboard.For more than 33 modules, a mechanical connection kit is used to join the 2combination uprights.Catalogue numbers for orderingDesignationCat. no.Combination kit 08816Two combination uprights 08817Multiple combination kit 0881875


EnclosuresSystem GIP30/IP31/IP43 floor-standingenclosuresCatalogue numbersDD380631Floor-standing enclosure (IP30)DD380634DD380635DD380636DD380637DD381354Basic floor-standing enclosure.No. of verticalmodulesHeight ofenclosureBasicenclosureEnclosureextensionPlain doorTransparentdoorFloor-standing enclosure (IP30)27 1530 08202 08212 08222 0823230 1680 08203 08213 08223 0823333 1830 08204 08214 08224 08234b two basic floor-standing enclosures cannot be combinedb to create a switchboard comprising a number of enclosures, use a basic floorstandingenclosure and one or more floor-standing enclosure extensionsb floor-standing enclosure extensions are supplied with a combination kit for thebasic floor-standing enclosure.b reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 82.Floor-standing enclosure extension.DD380632Duct, W = 300 mm (IP30)DD380638DD380639DD380640No. of verticalmodulesHeight of ductDuct,W = 300 mmPlain doorTransparentdoorDuct, W = 300 mm (IP30)27 1530 08272 08282 0829230 1680 08273 08283 0829333 1830 08274 08284 08294b the duct is supplied with a combination kit for the basic enclosureb reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 82.DD381258Duct front plate, see page 68.DD381257Canopy (IP31)The addition of a canopy over the floor-standing enclosure (and the duct) equippedwith a door ensures compliance with the degree of protection IP31 (see page 78).Gasket (IP43)When the floor-standing enclosure (and the duct) is equipped with a canopy, agasket for the door of the floor-standing enclosure (and the duct) ensures compliancewith the degree of protection IP43 (see page 78).76


EnclosuresSystem GIP30/IP31/IP43 floor-standingenclosuresCatalogue numbersDD381263Floor-standing enclosurecombinationsBasic enclosure + 300 mm wide ductThe combination kit (two mechanical combination brackets) is supplied with the duct.To make the combination more rigid, particularly during transport, it is advised to usea set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationSet of two lifting/reinforcement cross-members for basic floor-standingenclosure and 300 mm wide ductCat. no.08812Basic floor-standing enclosure + duct.DD381264Basic enclosure + enclosure extensionA combination kit for mechanical connection is supplied with the floor-standingenclosure extension.To make the combination more rigid, particularly during transport, it is mandatory touse a set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationSet of two lifting/reinforcement cross-members for basic floor-standingenclosure and extensionCat. no.08811Basic floor-standing enclosure + extension.DD381265Basic enclosure + 300 mm wide duct + extensionA combination kit for mechanical connection is supplied with the duct and the floorstandingenclosure extension.To make the combination more rigid, particularly during transport, it is mandatory touse a set of cross-members secured to the rear of the switchboard.Catalogue numbers for orderingDesignationSet of two lifting/reinforcement cross-members for basic floor-standingenclosure, 300 mm wide duct and extensionCat. no.08813Basic floor-standing enclosure + duct + extension.DD380633Plinth raiserDesignationCat. no.Plinth raiser, H = 100 mmfor basic floor-standing enclosure or extension 08805for a duct, W = 300 mm 0880777


EnclosuresSystem GIP30/IP31/IP43 enclosuresPartial doorsCanopyCatalogue numbersDD381266Partial doorb plain door or with cut-outs (for the interface with 72 x 72 or 96 x 96 mmmeasurement devices, see page 50)b height: 6 modulesb installation:v on a wall-mount enclosure at least 12 modules high (H u 630 mm)v on a basic floor-standing enclosure or extensionb reversible (opening to left or right), equipped with a handle and keylock (key 405).Note: Each wall-mount enclosure and basic floor-standing enclosure or extension can beequipped with only one partial door. The front must be completed with another door.The useful height behind a partial door is five modules.Cat. no. selectionDesignationCat. no.Partial plain door 08850Partial door with cut-outs for 72 x 72 or 96 x 96 mm devices 0885124-module wall-mount enclosure with a 6-module partial plaindoor and an 18-module plain door.DD381267Interface for 96 x 96 mm measurement devices on a partial door with cut-outs.DD381257Canopy (IP31)The addition of a canopy over a wall-mount or floor-standing enclosure equipped witha door ensures compliance with the degree of protection IP31.DesignationCat. no.Canopy for wall-mount or floor-standing enclosure alone 08830for wall-mount encl. + duct or floor-standing encl. + duct 08832for 2 wall-mount or 2 floor-standing enclosures 08831for 2 wall-mount encl. + duct or 2 floor-standing encl. + duct 08833DD381268Gasket (IP43)When the switchboard is equipped with a canopy, a gasket for the doors ensurescompliance with the degree of protection IP43.For combinations, order one gasket per door.DesignationCat. no.Gasket for one wall-mount encl./one floor-standing encl./one duct6 to 21 modules (L = 3300 mm) 0884024 to 33 modules (L = 5300 mm) 08841DD381256Flush-mount kitDesignationCat. no.Flush-mount kit for wall-mount enclosures, 6 to 18 modules 08819Flush-mount kit for wall-mount enclosures, 21 to 27 modules 0882078


EnclosuresSystem GIP30/IP31/IP43 enclosuresGland platesCatalogue numbersDD381269Gland platesMetal gland platesEnclosures (wall-mount, floor-standing, 300 mm wide ducts) are supplied with aplastic gland plate installed on the top or bottom panel.To cover all connection needs, the plastic gland plate can be replaced by a plainmetal gland plate supplied separately.DesignationCat. no.Plain metal gland platefor wall-mount and basic floor-standing enclosure or extension 08870for a duct, W = 300 mm 08874DD381270Special gland platesEnclosures (wall-mount, floor-standing, 300 mm wide ducts) are supplied with aplastic gland plate installed on the top or bottom panel.This gland plate can be replaced by an interface plate with cut-outs for special cableentry systems (membranes, FL21, etc.).DesignationCat. no.Interface plate with FL21 cut-outsfor wall-mount and basic floor-standing enclosure or extension 08871for a duct, W = 300 mm 08875Special FL21 gland plateplain 088814 x Ø29/48 mm 0889115 x Ø21/23 mm 0889220 x Ø16 mm entries 08895Ø16/30/47 mm entries 088962 x Ø66 mm entries 08897DD381271Gland plate for floor-standing enclosure plinthDesignationCat. no.Gland plate for plinthfor basic floor-standing enclosure or extension 08887for a duct, W = 300 mm 08888DD380861Top or bottom plate with plasticgland plateb top or bottom plate with cut-outs and a plastic gland plateb can be installed:v at the top or bottom of a wall-mount enclosure (or duct)v at the top of a floor-standing enclosure (or duct).DesignationCat. no.Plate with cut-outs + plastic gland platefor wall-mount or floor-standing enclosure 08880for a duct, W = 300 mm 0888479


EnclosuresSystem GIP30/IP31/IP43 enclosuresInstallation accessoriesCatalogue numbersDD381359Lifting accessoriesLifting ringsThe lifting rings are used to move a single wall-mount or floor-standing enclosure.For combined enclosures, use the lifting/reinforcement cross-members (see below).Cat. no. selectionDesignationCat. no.Set of two lifting rings for single wall-mount or floor-standing enclosures 08801DD381360Lifting/reinforcement cross-membersThe lifting cross-members, already installed to reinforce combined enclosures, haveholes for lifting.Cat. no. selectionDesignationCat. no.Set of two lifting/reinforcement cross-membersfor wall-mount or floor-standing enclosure alone 08810for two wall-mount or two floor-standing enclosures 08811for a wall-mount or floor-standing enclosure + 300 mm wide duct 08812for two wall-mount or floor-standing enclosures + 300 mm wide duct 08813DD381636DD381653Trunking spreaderFor a professional-looking connection between the trunking and the enclosure.Can be installed at the top or bottom.The spreader is marked for cut-outs for standard trunking sizes.The maximum capacity is two 250 x 80 mm trunking sections.DesignationCat. no.Trunking spreader 0882480


EnclosuresSystem GIP30/IP31/IP43 enclosuresInstallation accessoriesCatalogue numbersDD381362Wall mounting<strong>Switchboards</strong> can be mounted on a wall in three manners:b through the rear of the switchboardb using the lifting/reinforcement cross-membersb using external wall-mount brackets.Cat. no. selectionDesignationCat. no.Set of two lifting/reinforcement cross-membersSee previouspage.Four external wall-mount brackets 08803Mounting through the rear.DD381363Mounting using the lifting/reinforcement cross-members.DD381364Mounting using the external wall-mount brackets (08803).81


EnclosuresSystem GEnclosure accessoriesDoor handles and locksCatalogue numbersDD380656Handles (except System G IP55)DD380652DesignationCat. no.EURO handle without barrel 08932DD381201DesignationCat. no.ASSA handle without barrel 08933DD381202DesignationCat. no.Standard handle without insert or barrel 08930Can be equipped with all the barrel locks and inserts presentedbelow.Barrel locks, insertsDD381204DD381203DD382442PadlockingThe barrel locks and inserts below can be mounted on handle 08930 and on all thedoor handles of the <strong>Prisma</strong> <strong>Plus</strong> range (except System G IP55) after removing thestandard barrel lock (key no. 405).DesignationCat. no.Barrel locksBarrel lock + 2 keys no. 405 08940Barrel lock + 2 keys no. 455 08941Barrel lock + 2 keys no. 1242E 08942Barrel lock + 2 keys no. 3113A 08943Barrel lock + 2 keys no. 2433A 08944InsertsDIN double bar insert 08945Screwdriver slot insert 089466.5 mm male triangle insert 089477 mm male triangle insert 089488 mm male triangle insert 089499 mm male triangle insert 089506 mm male square insert 089517 mm male square insert 089528 mm male square insert 089536 mm female square insert 08955DesignationCat. no.Handle padlocking kit 08938The kit can be installed on the door handles of the <strong>Prisma</strong> <strong>Plus</strong> range(except System G IP55) equipped with any of the barrel locks and inserts above.82


EnclosuresSystem GIP55 enclosuresPresentationCatalogue numbers<strong>Prisma</strong> <strong>Plus</strong> IP55 enclosures are designedfor indoor switchboards in severeenvironments such as industrial andagricultural buildings, basements, kitchens,etc.All System G components can be used toform switchboards that:b have heavy-duty IP55 / IK10characteristicsb can be dismantled and combined tofacilitate installation, on-site connectionsand later modificationsb offer functional installation of control andindication devices (lights, pushbuttons, etc.)on the front of the switchboard, on a plain orpartial doorb offer functional installation of Schneiderindustrial socketsb can be installed anywhere in a building (ona wall, on a pole, on free-standingstructures, etc.).PD390596PD390666Installation on a wall structure.84


EnclosuresSystem GIP55 enclosuresPresentationCatalogue numbersPD390537PD390538Sockets on a partial door.Sockets on the side.PD390539PD390540Lights and pushbuttons on a partial door.Extended rotary handle on a door.PD390499PD390501Gland plates on an enclosure and a duct.Gland plates on an enclosure.85


EnclosuresSystem GIP55 enclosuresCatalogue numbersDD381429EnclosureDD381521DD381522DD381523No. of verticalmodulesHeight(mm)Enclosure Plain door TransparentdoorBasic enclosure7 450 08302 08322 0833211 650 08303 08323 0833315 850 08304 08324 0833419 1050 08305 08325 0833523 1250 08306 08326 0833627 1450 08307 08327 0833733 1750 08309 08329 08339b reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 92.DD381431Duct, W = 300 mmDD381527DD381528No. of verticalmodulesHeight(mm)Rear + door,W = 300 mmTop andbottomplatesDuct, W = 300 mm7 450 08342 0837211 650 08343 0837215 850 08344 0837219 1050 08345 0837223 1250 08346 0837227 1450 08347 0837233 1750 08349 08372b reversible doors (opening to left or right), equipped with a handle and keylock(key 405). For other possibilities, see page 92.DD381430Enclosure extensionDD381524DD381525DD381524DD381526No. of vertical Height Side-by-side combination Vertical combinationmodules (mm) Rear + Top and bottom Rear + Side panelsplatesEnclosure extension7 450 08312 08371 08312 0835211 650 08313 08371 08313 0835315 850 08314 08371 08314 0835419 1050 08315 08371 08315 0835523 1250 08316 08371 08316 0835627 1450 08317 08371 08317 0835733 1750 08319 08371 08319 08359b the enclosure extension uses the same doors as the basic enclosure.86


EnclosuresSystem GIP55 enclosuresCatalogue numbersDD381432Combination kitsIP55 enclosures can be combined side-by-side and vertically.To make a combination, start with a basic enclosure and add a duct or one (or more)enclosure extensions using the corresponding combination kits.Cat. no. selectionDesignationCat. no.Combination kithorizontal/vertical (two double struts) 08381"L" shape (one triple strut and one single strut) 08382square shape (one quadruple strut) 08383Note: For combinations of more than two enclosures, the switchboard must be reinforced usingmounting uprights (08391), see page 90.DD381434Examples of combinationsVertical combinationA basic enclosure is positioned above an enclosure extension, whatever its height.Use the horizontal/vertical combination kit with two double struts.Catalogue numbers for the configuration oppositeItem Designation Cat. no.1 1 basic enclosure 083042 1 rear plate for enclosure extension 083133 1 set of two side panels 083534 1 horizontal/vertical combination kit 08381See previous page for plain and transparent doors for basic enclosures andextensions.DD381435"L" combinationThe "L" shape is created by combining two enclosures (extension or duct) with abasic enclosure.Catalogue numbers for the configuration oppositeItem Designation Cat. no.1 1 basic enclosure 083042 1 rear + door for duct, W = 300 mm 083443 1 set of two top and bottom plates for duct 083724 1 rear plate for enclosure extension 083135 1 set of two side panels 083536 1 "L" combination kit 083827 1 horizontal/vertical combination kit 08381See previous page for plain and transparent doors for basic enclosures andextensions.DD381436Square combinationThe square shape is created by combining three enclosures (extension or duct) witha basic enclosure.Catalogue numbers for the configuration oppositeItem Designation Cat. no.1 1 basic enclosure 083032 3 rear plates for enclosure extensions 083133 1 set of two top and bottom plates for enclosure extensions 083714 1 set of two side panels 083535 1 square combination kit 083836 2 horizontal/vertical combination kits 2 x 083817 3 mounting uprights (to reinforce the switchboard) 3 x 08391See previous page for plain and transparent doors for basic enclosures andextensions.87


EnclosuresSystem GIP55 enclosuresPartial doorsSide panels with cut-outsCatalogue numbersPartial doorsWhether plain or with cut-outs, they can be mounted on basic enclosures orextensions at least eleven modules high (H = 650 mm).They are equipped with:b hinges that open 170°b a 8 mm male triangle insert (key not supplied).The front can be completed with a standard door, either plain or transparent.Each basic enclosure or extension can be equipped with only one partial door.DD381437Partial plain doorDesignationCat. no.Partial plain door4 modules (H = 200 mm) for enclosures from 11 to 27 modules high 083746 modules (H = 300 mm) for enclosures 33 modules high 08375DD381438Partial door with cut-outsDesigned for two mounting plates with 22 mm diameter devices or Schneiderindustrial sockets.DesignationCat. no.Partial door with cut-outs4 modules (H = 200 mm) for enclosures from 11 to 27 modules high 083766 modules (H = 300 mm) for enclosures 33 modules high 08377They are supplied with an insulating plain mounting plate that can be used to blankoff a reserve hole or to install all types of devices (sockets, EPO devices,measurement devices).The dimensions of the two holes are 200 mm x 112 mm.DD381439Tego Dial partial doorDesigned for "Tego Dial" mounting plates (H = 100 mm) on which it is possible tomount control, monitoring, measurement and indication devices.DesignationCat. no.Tego Dial partial door4 modules (H = 200 mm) for enclosures from 11 to 27 modules high 083786 modules (H = 300 mm) for enclosures 33 modules high 08379The cut-out is 375 mm wide (five 75 mm modules).For selection of Tego Dial mounting plates, see the Schneider industrial controlcatalogue.DD381440Side panel with cut-outSide panel with two cut-outs (only one for 7 and 11-module panels) for mountingplates intended for 22 mm diameter devices and those for industrial sockets.These panels simply replace a standard side panel.Can be mounted on the left or right-hand side.Supplied with one blanking plate (except for the 7 and 11-module panels).DesignationCat. no.1 side panel with cut-out7 mod. 0836211 mod. 0836315 mod. 0836419 mod. 0836523 mod. 0836627 mod. 0836733 mod. 0836988


EnclosuresSystem GIP55 enclosuresFunctional mounting platesCatalogue numbersMounting plates for 22 mmdiameter devices or industrialsocketsPlastic mounting plates are used for 22 mm diameter devices or industrial socketson the outside of the switchboard.They can be installed:b horizontally on the partial doors with cut-outsb vertically on the side panels with cut-outs■ horizontally vertically at any point on a door or side panel.DD381441Plain mounting plateA plain plate is used to blank off partial doors or side panels with cut-outs.DesignationCat. no.Plain mounting plate, 210x150 mm 08861Can be used to mount any type of device (EPO devices, measurement devices,sockets).DD381442Mounting plate for 22 mm diameter devicesFor installation of eight 22 mm diameter devices (lights, switches, pushbuttons, etc.).DesignationCat. no.Mounting plate with eight 22 mm diameter holes 08862Supplied with 4 blanking plugDD381438DD381443Mounting plate for Schneider industrial socketsMounting plate with two 65 x 85 mm holes.Intended for the installation of:b 10/16 A residential socketsb inclined 16 A IP44 and IP67 sockets.DesignationCat. no.Mounting plate with two 65 x 85 mm holes 08863Supplied with a 65 x 85 mm blanking plate.DD381444Mounting plate with two holes, 65 x 85 mm and 90 x 100 mmIntended for the installation of:b inclined 16 and 32 A IP44 and IP67 sockets in the 90 x 100 mm hole (1)b residential sockets (< 10/16 A) in the 65 x 85 mm hole (1a)b inclined 16 A IP44 and IP67 sockets in the 65 x 85 mm hole (1b).DesignationCat. no.Mounting plate with two holes, 65 x 85 mm and 90 x 100 mm 08864Supplied with a 65 x 85 mm blanking plate.89


EnclosuresSystem GIP55 enclosuresInstallation accessoriesCatalogue numbersDD381446Mounting supportsMounting uprightsThe uprights are used to mount on a wall one or more enclosures combinedhorizontally or vertically.The uprights leave space behind the switchboard for cable running and to improveventilation.Colour RAL7016.For one enclosure, order two uprights.For each enclosure extension or duct, order one additional upright.DesignationCat. no.1 mounting upright (L = 1950 mm) 08391Supplied with:b two adjustable fixing bracketsb one joint for combination with a plinth or another upright.Note: To create the configuration opposite, order:three mounting uprights (08391 x 3).DD381447Plinth, H = 150 mmThe plinth, installed in the factory or on-site, raises the switchboard to protect it andfacilitate spreading of cables arriving from a trough.Colour RAL7016.The wall-fixing brackets supplied with the plinth ensure that the switchboard cannottopple over.For the basic enclosure, order two gussets and one 600 mm wide plinth cover panel.For each enclosure extension or duct, order one additional gusset and thecorresponding cover panel.DesignationCat. no.Plinth gusset 08392Plinth cover panel, W = 600 mm (for enclosure) 08393Plinth cover panel, W = 300 mm (for duct) 08394Note: To create the configuration opposite, order:three plinth gussets (08392 x 3)one plinth cover panel, W = 600 mm (08393)one plinth cover panel, W = 300 mm (08394).DD381448Wall structureThe switchboard can be mounted on the structure in the factory or on site.Two wall-fixing brackets supplied with the basic enclosure ensure that theswitchboard cannot topple over.Colour RAL7016.DesignationCat. no.1 mounting upright (L = 1950 mm) 083911 plinth gusset 08392Plinth cover panel, W = 600 mm (for enclosure) 08393Plinth cover panel, W = 300 mm (for duct) 08394Nota : To create the configuration opposite, order:three mounting uprights (08391 x 3)three plinth gussets (08392 x 3)one plinth cover panel, W = 600 mm (08393)one plinth cover panel, W = 300 mm (08394).DD381449Free-standing structureThe free-standing structure is simply two wall structures combined back-to-back.The switchboard can be positioned anywhere.It can be fixed to the floor and moved easily using the lifting rings (08396).It can be equipped with one or more enclosures with Schneider sockets.Colour RAL7016.DesignationCat. no.1 mounting upright (L = 1950 mm) 083911 plinth gusset 08392Plinth cover panel, W = 600mm (for enclosure) 08393Plinth cover panel, W = 300 mm (for duct) 08394Note: To create the configuration opposite, order:four mounting uprights (08391 x 4)four plinth gussets (08392 x 4)two plinth cover panels, W = 600 mm (08393 x 2).90


EnclosuresSystem GIP55 enclosuresInstallation accessoriesCatalogue numbersDD381450Mounting on a poleThe kit is used to mount an enclosure or an enclosure + duct combination, withoutdrilling, to an I-beam or concrete pole that can be rectangular or cylindrical.The maximum circumference of the pole is 580 mm.DesignationCat. no.Pole-mount kit for enclosures 08395The kit is made up of:b two reinforcement cross-members to support the enclosureb mounting components and hardware.DD381451CanopiesInstalled on the mounting uprights or directly on the wall, canopies improveswitchboard protection against vertically falling water and objects.Colour RAL7016.DesignationCat. no.Canopy, W = 600 (for enclosure) 08386Canopy, W = 300 (for duct) 08387Supplied with:b the hardware required for mounting on the uprightsb the components required for combination with another canopy.DD381452Membrane-type gland plates(IP55)These gland plates are made of an insulating material and simply replace thestandard steel gland plates supplied with the enclosure (two plates) or the duct (oneplate).Different size cables can enter the switchboard through the bottom without usingcable glands while maintaining the degree of protection IP55.DesignationCat. no.Gland plate with 39 entries 08898for three 14 to 26 mm diameter cables +four 10 to 20 mm diameter cables +thirty-two 7 to 16 mm diameter cablesGland plate with 2 entries 08899fortwo 33 to 72 mm diameter cablesDD381453DD381455DD381454Lifting ringsThe lifting rings are secured directly to the switchboard or to the mounting uprights.Supplied with mounting hardware.DesignationCat. no.Set of two lifting rings 0839691


EnclosuresSystem GIP55 enclosuresClosing accessoriesCatalogue numbersDD380704PresentationHandlesThe small plain and transparent doors (7 to 23 modules) are supplied with a smallhandle comprising a barrel lock no. 405.The large plain and transparent doors (27 to 33 modules) are supplied with a largehandle comprising a barrel lock no. 405.The partial doors are supplied with an 8 mm male triangle insert.All doors can receive as optional equipment:b a large or small handle with a barrel lock no. 405. The latter can be replaced byother barrel locks or special insertsb a large EURO handle, supplied without a barrel lockb door inserts (squares, triangles, double bars, screwdriver slots).Replacement handlesDesignationCat. no.Door latch with lock and 2 no. 405 keys 08936Handle L = 155 mm) with lock and 2 no. 405 keys 08935EURO handle without a barrel lock (1) 08934(1) Do not suit to barrels with an automatic return stroke of the key.DD380705Door insert These inserts simply replace a standard handles.DesignationCat. no.Screwdriver slot insert 099813 mm double bar insert 099827 mm male triangle insert 099838 mm male triangle insert (CNOMO) 099849 mm male triangle insert (EDF) 099856 mm male square insert 099867 mm male square insert 099878 mm male square insert 099886 mm female square insert 09989DD380706Handle barrel locks and inserts Barrel locksThese components may equip handles after removing the standard barrel lock no.405.DesignationCat. no.Barrel lock + 2 keys no. 2433A 09933Barrel lock + 2 keys no. 455 09945Barrel lock + 2 keys no. 1242 E 09942Barrel lock + 2 keys no. 3113 A 09943Other A and E combinations are available from Ronis, please consult us.InsertsDesignationCat. no.Screwdriver slot insert 099316 mm female square insert 099466 mm male square insert 099497 mm male square insert 099478 mm male square insert 099487 mm male triangle insert 099378 mm male triangle insert (CNOMO) 099389 mm male triangle insert (EDF) 099393 mm double bar insert 0993292


EnclosuresSystem GIP55 enclosuresClosing accessoriesCatalogue numbersDD380707PadlockingKit designed for three padlocks.DesignationCat. no.IP55 handle padlocking kit 08939The kit can be installed on all IP55 doors, except those equipped with an EURO lock.93


DistributionSystem GPartitioningCatalogue numbersDD381418Horizontal partitioningPresentationThe partition is a metal barrier installed in a wall-mount enclosure, a floor-standingenclosure or a 300 mm wide duct.It is used to:b separate the functional units from one anotherb create a physical separation between devices and a terminal block, for example.It is mounted directly on the functional uprights.Lateral and rear knock-outs are available for cable running or the installation ofbusbars at the rear of the switchboard.Cat. no. selectionDesignationCat. no.Horizontal partitionfor wall-mount or floor-standing enclosure 04331for a duct, W = 300 mm 04332DD38141994


DistributionSystem GPartitioningCatalogue numbersDD381420Vertical partitioningPresentationThe metal partition creates a physical separation between the device compartmentand the 300 mm wide duct of a wall-mount enclosure or a floor-standing enclosure.It is used to:b separate the devices from busbars or a distribution block installed in the ductb set up a special zone for terminal blocks in the duct.There are knock-outs for cable running.It can be cut to length every 150 mm and can be used for partitioning up to 33-modulein wall mount enclosure and floor-standing enclosure (H = 1830 mm).Cat. no. selectionDesignationCat. no.Vertical partition 04330DD38142195


DistributionSystem GMain distributionPowerclip busbarsCatalogue numbersPowerclip busbarsPowerclip busbars are compact and fully insulated(IPxxB).They are supplied ready for installation in theswitchboard.There are three and four-pole versions with ratingsfrom 125 to 630 A.Available in four lengths, they can by cut every 150 or200 mm, depending on the rating (see page 99).PD390454PD390545PD390544Additional 35 mm² blocks installed on theconnection between the device and the busbars.Powerclip tap-off blocks for 6 and 10 mm²cables.PD390546PD390547Clip-on covers insulate the cable lugs.200 A connection for a Multiclip distributionblock.96


DistributionSystem GCatalogue numbersPolybloc centralised distributionblockThe Polybloc distribution block is designed for optimuminstallation directly downstream of horizontal CompactNS100/250 and Interpact INS250 devices.Mounting is very fast. It simply hooks onto the devicemounting plate. Electrical connections are madedirectly to the device terminals.It has the same width as the devices and does notrequire extra space in the switchboard.The connection terminals are slanted to facilitate cableentry and reduce the space required behind the frontplate (see page 110)400 A rear busbarsThe rear busbars are mounted directly on the rear ofenclosures.There are three and four-pole versions with ratingsfrom 160 to 400 A.Available in two lengths, 1000 and 1400 mm, they canbe cut as needed (see page 100).PD390534PD390532Main distributionPolybloc centralised distribution block400 A rear busbars630 A multi-stage busbars630 A multi-stage busbarsThe multi-stage busbars are installed in a 300 mm wideduct.They are particularly useful for distribution to twoenclosures on each side of the duct.All connection points are easily accessible from thefront.The inclination of the bars facilitates connections andimproves cable running.There are three and four-pole versions with ratingsfrom 160 to 630 A.Available in two lengths, 1000 and 1400 mm, they canbe cut as needed (see page 102).PD39053397


DistributionSystem G630 A Powerclip busbarsCatalogue numbersPresentationPowerclip busbars are compact and fullyinsulated (IPxxB).They are supplied ready for installation inthe switchboard.There are three and four-pole versions withratings from 125 to 630 A.Available in four lengths, they can be cutevery 150 or 200 mm, depending on therating.PD390461DD381378CompositionPowerclip busbars are made up of ETP H12 channelled copper bars with threadedM6 holes every 25 mm.They are mounted on insulated bases and can be cut every 150 or 200 mm,depending on the rating.The ends of the busbars are plugged.Clip-on covers protect against direct contact from the front. The covers can be easilycut for the connections to the devices.InstallationThe busbars are supplied with supports that screw to the functional uprights ofenclosures or to an adapter in a cubicle.They can be cut every 150 or 200 mm, depending on the rating.Electrical characteristicsPermissible current ofthe busbars (A)Rated short-time withstandcurrent Icw (kA rms / 1second)125 8.5 20160 10 30250 13 30400 20 52.5630 25 52.5b rated insulation voltage:v Powerclip 125 A busbars: Ui = 500 Vv Powerclip 160 A busbars: Ui = 750 Vb impulse withstand voltage:v Powerclip 125/160 A busbars: Uimp = 8 kV.Rated peak withstand current Ipk(kÂ)125 A Powerclip busbars Available in two lengths (450 and 750 mm) in three and four-pole versions.The busbars can be cut to length every 150 mm.They are supplied with clip-on covers that block off the connected cable lugs and canbe cut as needed.Cat. no. selectionPowerclip busbars 125 ACat. no.Three-pole L = 450 mm 04103L = 750 mm 04107Four-pole L = 450 mm 04104L = 750 mm 04108Busbar connectionFour 125 A connections, L = 230 mm04145(for NG125, NSA and INS equipped with tunnel terminals)A 35 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.95 mm² tunnel terminals for INS :cat. no. 28947 (set of 3)cat. no. 28948 (set of 4)98


DistributionSystem G630 A Powerclip busbarsDD381380Catalogue numbers160/630 A Powerclip busbars Available in two lengths (1000 and 1400 mm) in three and four-pole versions. Thebusbars can be cut to length every 200 mm.Prefabricated connections are available for the devices.Powerclip busbars 160 A 250 A 400 A 630 AThree-pole L = 1000 mm 04111 04112 04113 04114L = 1400 mm 04116 04117 04118 04119Four-pole L = 1000 mm 04121 04122 04123 04124L = 1400 mm 04126 04127 04128 04129Connection between incoming device and Powerclip busbars Cat. no.Power supply block (with connection) NS250 04060NS400 04070NS630 04071Universal power supply block100/250 A 04061(without connection)400/630 A 04074Connection for universal power supply block Vertical NS100/250 04062Vertical NS100/250 in duct 04064Vertical NS400/630 in duct 04073DD381381DD381382DD381405NS400 power supply block (04070) betweenincoming device and busbars.NS250 power supply block (04060) betweenbusbars and Compact NS250.250 A universal power supply block (04061) +250 A connection (04062) between incomingdevice and busbars.Connection between 200 A Multiclip and Powerclip busbars Cat. no.200 A 4P connection for Multiclip (supplied with mounting hardware) 0402135 mm² additional blocks Cat. no.35 mm² additional blocks 3P 041554P 04156Busbar connection4 160 A connections, L = 230 mm(for NSA160)35 mm² 4P additional blocks (04156). A 45 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.Cat. no.04146DD381384DD381385AccessoriesPowerclip tap-off blocksEach block can be used to connect:b one 6 mm² and one 10 mm² cable (04151)b one 16 mm² cables (04152).Equipped with spring terminals.Designation12 Powerclip tap-off blocks with 6 mm² + 10 mm² terminals 0415112 Powerclip tap-off blocks with 16 mm² terminals 04152Connection coverClip-on covers that block off the connected cable lugs and can be cutas needed.Cat. no.They maintain IPxxB with 90° angle lugs and/or cable sizes from 10 to 25 mm².DesignationCat. no.8 IPxxB covers for Powerclip busbars 041508.8 class mounting hardwareUsed for electrical connections to the copper bars.DesignationCat. no.Set of 20 CHC M6 x 12 mm screws for Powerclip busbars 0415899


DistributionSystem G400 A rear busbarsCatalogue numbersPresentationThe rear busbars are mounted directly onthe uprights of the framework.There are three and four-pole versions withratings from 160 to 400 A.Available in two lengths, 1000 and1400 mm, they can be cut as needed.The connection with a Compact or Interpactincoming device occupies two verticalmodules (50 mm each).PD390548CompositionFlat, copper bars with threaded M6 holes every 25 mm for connection along theentire length of the busbars.The insulating supports can receive a fifth bar, 15 x 5 mm or 20 x 5 mm, to create anearth bar.InstallationThe busbars are mounted directly on the functional uprights of enclosures or on anadapter (03595) in a cubicle.Connectionb 16 mm² to 50 mm² flexible cables, with crimped lugsb insulated flexible bars (see page 104).Electrical characteristicsb rated peak withstand current Ipk (kÂ)- 30 k for 160 A busbars- 40 k for 250 A busbars- 55 k for 400 A busbarsb rated insulation level Ui = 1000 VBusbar calculationBusbar size and distance between supportsThe table below indicates:b the size of the bars to be used, depending on the permissible current level in thebusbarsb the distance between supports, depending on the rated short-time withstandcurrent (Icw).Rating(A)Size of bars(mm)Distance between support centres(mm)Icw (kA rms / 1 s)10 13 15 20 25160 15 x 5250 20 x 5400 32 x 5 450 300 225100


DistributionSystem G400 A rear busbarsCatalogue numbersDD381387Busbar selectionCopper bars Rating (A) Size of bars (mm) Cat. no.Four copper bars, L = 1000 160 15 x 5 04161250 20 x 5 04162400 32 x 5 04163Four copper bars, L = 1400 160 15 x 5 04171250 20 x 5 04172400 32 x 5 04173Busbar supportsRear busbar support 04191DD381388DD381389Copper bars.Busbar supports.DD381192AccessoriesRear busbar barrierProtects against direct contact with the busbar connections.Supplied with mounting hardware.DesignationCat. no.Rear busbar barrier, H = 100 mm 04198DD38145604198.125 A connectionFor direct supply to comb busbars from the rear busbars in the switchboard.DesignationCat. no.Four 125 A connections, L = 230 mm04145(for NG125, NSA and INS equipped with tunnel terminals)A 35 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.95 mm² tunnel terminals for INS :cat. no. 28947 (set of 3)cat. no. 28948 (set of 4)160 A connectionFor direct supply to an NSA160 from the rear busbars in the switchboard.04145. Designation Cat. no.4 160 A connections L = 230 (for NSA160) 04146A 45 mm² ferrule for connection to tunnel terminals is crimped to one end.A 45° ring lug is crimped to the other end.DD381457200 A connectionFor supply of a 200 A Multiclip distribution block from the rear busbars in theswitchboard.DesignationCat. no.Rear busbar connection for 200A Multiclip distribution block 0402904029.Connection between busbarsFor electrical connections between two sets of rear busbars.DesignationCat. no.4 copper angle brackets, 250A 04190DD3814588.8 class mounting hardwareDesignationCat. no.Set of 20 M6 x 20 bolts (20 bolts + 20 nuts +40 contact washers) 04194Set of 40 M6 x 16 screws (40 screws + 40 contact washers) 0419504190.101


DistributionSystem G630 A multi-stage busbarsCatalogue numbersPresentationThe multi-stage busbars are installed in a300 mm wide duct.They are particularly useful for distribution totwo enclosures on each side of the duct.All connection points are easily accessiblefrom the front.The inclination of the bars facilitatesconnections and improves cable running.There are three and four-pole versions withratings from 160 to 630 A.Available in two lengths, 1000 and1400 mm, they can be cut as needed.PD390535CompositionFlat, copper bars with threaded M6 holes every 25 mm for connection along theentire length of the busbars. There are 8.2 mm diameter holes at each end for supply.The staggered supports are made of an insulating material.An optional, insulating, front barrier is available to protect against direct contact fromthe front.InstallationThe busbars are installed in a 300 mm wide duct for the enclosures.Connectionb 16 mm² to 50 mm² flexible cables, with crimped lugsb insulated flexible bars (see page 104).Electrical characteristicsb rated peak withstand current Ipk (kÂ)- 30 k for 160 A busbars- 40 k for 250 A busbars- 55 k for 400 A busbars- 55 k for 630 A busbarsb rated insulation level Ui = 750 V.Busbar calculationBusbar size and distance between supportsThe table below indicates:b the size of the bars to be used, depending on the permissible current level in thebusbarsb the distance between supports, depending on the rated short-time withstandcurrent (Icw).Rating (A) Size of bars (mm) Distance between support centres(mm)Icw (kA rms / 1 s)10 13 15 20 25160 15 x 5250 20 x 5400 32 x 5 450 300 300 (1)630 32 x 8(1) Icw (kA rms/0.6 s).102


DistributionSystem G630 A multi-stage busbarsCatalogue numbersDD381393Busbar selectionCopper barsCopper bars Rating (A) Size of bars (mm) Cat. no.Four copper bars,L = 1000 mmFour copper bars,L = 1400 mm160 15 x 5 04161250 20 x 5 04162400 32 x 5 04163160 15 x 5 04171250 20 x 5 04172400 32 x 5 04173630 32 x 8 04174Busbar supportsMulti-stage busbar support 04192DD381388DD38139504192.DD381396AccessoriesMulti-stage busbar barrierProtects against direct contact with the busbar connections from the front.Supplied with mounting hardware.DesignationCat. no.Multi-stage busbar barrier, L = 1500 mm 04197DD381397Multiclip connectionFor supply to a 200 A Multiclip.DesignationCat. no.Multi-stage busbar 4P connection for 200 A Multiclip distribution block 04024DD3813988.8 class mounting hardwareDesignationCat. no.Set of 20 M6 x 20 bolts (20 bolts + 20 nuts +20 contact washers) 04194Set of 40 M6 x 16 screws (40 screws + 40 contact washers) 04195103


DistributionSystem GInsulated flexible barsCatalogue numbersDD381659PresentationCatalogue number selectionThe insulated flexible bars are tested in a type-tested switchboard environment.Their design takes into account the switchboard architecture where they are often inclose proximity to a protection device (circuit breaker or fuse) with significant heatlosses.In-depth knowledge of switchboard architecture and the connected devices led to theestablishment of a selection table based on the type of device.Flexible bars are 1800 mm long and made of copper with an insulating sheath.Rated insulation level Ui = 1000 V.The sizes for the flexible bars indicated below take into account the heat losses ofSchneider devices in a <strong>Prisma</strong> <strong>Plus</strong> switchboard.Connection between device and busbarsThe flexible bars are determined taking into account the connected device, whateverthe internal temperature of the switchboard.The bar sizes indicated below take into account the derating curves of devices.Device Size (mm) Cat. no.NS100/160 20 x 2 04742NS250 20 x 3 (1) 04743NS400 32 x 5 04751NS630 32 x 8 04753INS125/160 20 x 2 04742INS250 20 x 3 04743INS400 32 x 5 04751INS630 32 x 6 04752200 A Multiclip 20 x 3 04743Polypact, 3P 32 x 6 04752Polypact, 4P 32 x 6 04752Fupact 250 24 x 5 04746Fupact 400 32 x 5 04751Fupact 630 32 x 8 04753(1) To connect a Compact NS250 to Powerclip busbars, use a 24 x 5 mm flexible bar (04746).Connection between busbarsFlexible bars are designed for connections between busbars taking into account thefollowing characteristics:a maximum temperature of 60°C inside the switchboard. This corresponds to theaverage temperature inside a switchboard for an ambient temperature of 35°Cb the maximum withstand temperature for the insulating material is 125°C.Ie max. (A) Size (mm) Cat. no.200 20 x 2 04742250 20 x 3 04743400 24 x 5 04746520 32 x 5 04751580 32 x 6 04752660 32 x 8 04753DD382008104


105


DistributionSystem GOverview of distribution blocksCatalogue numbersPD390651DesignationRated insulationvoltage UiRated impulsewithstand voltageUimpRated operationalcurrent Ie (40°C)Rated short-timewithstandcurrentIcwDistribloc distribution block 750 V 8 kV 125/160 A Depending onconnected deviceRated peakwithstandcurrent IpkDepending onconnected devicePD390652Polybloc distribution block 750 V 8 kV 250 A Depending onconnected deviceDepending onconnected devicePD390653160/630 A multi-stage distributionblock750 V 8 kV 160/630 A 10 kA rms / 1 s for 160 Ablock13 kA rms / 1 s for 250 Ablock20 kA rms / 1 s for 400 Ablock25 kA rms / 1 s for 630 Ablock30 k for 160 and250 A block40 k for 400 and630 A blockPD39065480 A Multiclip distribution block 500 V 6 kV 80 A Depending onconnected deviceDepending onconnected device200 A Multiclip distribution block 750 V 8 kV 200 APD390655PD390683For distribution by comb busbars (63/125 A), strip terminal blocks (80/125 A) or multi-stage distribution blocks(40/125 A), see device catalogue.106


DistributionSystem GOverview of distribution blocksCatalogue numbersConnection capacityUpstreamDownstreamInstallation / commentsBb tunnel terminals for 6 to 35 mm² flexiblecables (10 to 35 mm² rigid cables) for 125 ADistriblocb prefabricated connections (supplied) for160 A Distriblocb spring terminals:v 2 outgoers from 1 to 10 v , flexible or rigidv 3 outgoers from 1 to 6 v , flexible or rigidv 7 outgoers from 1 to 4 v , flexible or rigidb tunnel terminals:v 1 outgoer from 4 to 16 v , flexible (4 to 25 vrigid)b modular railb plain or slotted backplatesee page 108Bb directly to the incoming device:Compact NS 100/250, Interpact INS250b spring terminals:v 6 x 10 v + 3 x 16 mm², flexible or rigidb directly downstream of the incomingdevice:Compact NS 100/250, Interpact INS250b modular railb plain or slotted backplatesee page 110Bb cables:v 16 to 50 mm² with crimped lugb flexible bars,see page 104.b 13 outgoers via 50 v max. cables withcrimped lugsb screwed to the rear of a wall-mount orfloor-standing enclosureb screwed in the 300 mm duct of a wallmountor floor-standing enclosuresee page 112b tunnel terminals for cables y 25 mm²b supplied flexible cables:v 6 and 10 mm²b clipped onto rear of modular railb screwed to plain or slotted backplatesee page 114Bb via prefabricated connections from rearbusbarsb via prefabricated connections fromPowerclip busbarsb 50 mm² cables with crimped lugsb 20 x 3 mm flexible bars,see page 104b supplied flexible cables:v 10 mm²see page 47see page 122107


DistributionSystem GDistribloc distribution blockCatalogue numbersDD381660PD390651DD381399GeneralCable connection.Distribloc distribution blockPD390657Downstream circuits are connected from the front, to spring terminals.Contact pressure automatically adapts to the size of the conductor. It does notdepend on the operator.Contacts are insensitive to vibrations and thermal variations.Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a springterminal.Degree of protection: IPxxB.Advantagesb a reliable electrical connection, no maintenance required (tightness guaranteedover time)b very fast connectionb easy phase balancingb rewiring is very easy if the switchboard is expanded or modified.The four-pole distribution block is made up of:b a fully insulated, one-piece distribution block complying with the degree ofprotection IPxxB (protection against direct contacts)b a modular cover.The design of the front (45 mm nose) blends perfectly into a row comprising modulardevices.DesignationCat. no.125 A Distribloc distribution block 04045160 A Distribloc distribution block + connection 04046Electrical characteristicsb rated insulation level: Ui = 750 Vb rated operational current Ie (40°C):v 125 A for the 125 A Distriblocv 160 A for the 160 A Distribloc with its prefabricated connection for INS160 orNSA160b short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have beentested.b complies with the low-voltage device standard IEC 60947.7.1 and/or IEC 60439.1b impulse withstand voltage Uimp = 8 kV.Supplyb tunnel terminal on 125 A Distribloc 125 for 6 to 35 v flexible cables (10 to 35 v rigidcables)b the 160 A Distribloc is supplied with a prefabricated flexible connection. It isdesigned for an INS100/160 or NSA160 switch-disconnector, installed on the left orright.Distribution (125 and 160 A Distribloc)b spring terminals:v 2 outgoers from 1 to 10 v , flexible or rigidv 3 outgoers from 1 to 6 v , flexible or rigidv 7 outgoers from 1 to 4 v , flexible or rigidb tunnel terminals:v 1 outgoer from 4 to 16 v , flexible (4 to 25 v rigid)Supplyb an identification labelb adhesive labels for phase identificationb a prefabricated flexible connection for the INS160 or NSA160 (160 A Distribloconly).DD381611108


DistributionSystem GDistribloc distribution blockCatalogue numbersInstallationb clipped onto a modular railb width occupied is 12 modules (9 mm each)b screwed to plain or slotted backplate. Distances between centres = 100 x 75 mm.DimensionsPD390658DD381608DD381609125 A connection Set of four flexible connections, 35 v, , L = 210 mm.To supply a 125 A Distribloc from an NG125 or an INS125.DesignationCat. no.4 NG-INS125 connections for Distribloc 04047DD380932109


DistributionSystem GPolybloc distribution blockCatalogue numbersDD381399GeneralDownstream circuits are connected from the front, without screws, to springterminals. Contact pressure automatically adapts to the size of the conductor(minimum size = 1 mm 2 ). Contacts are insensitive to vibrations and thermalvariations.Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a springterminal.Degree of protection: IPxxB.Advantages of spring terminalsb a reliable electrical connection, no maintenance requiredb the fast connections make phase balancing very easy.b rewiring is very easy if the switchboard is expanded or modified.PD390549250 A Polybloc distribution block ApplicationsThe Polybloc distribution block is designed for installation directly downstream ofCompact circuit breakers and Interpact switch-disconnectors devices up to 250 A.It can be rapidly mounted in the horizontal position. Electrical connections are madedirectly to the device terminals.It has the same width as the devices and does not take up any additional space inthe switchboard.The connection terminals are slanted to facilitate cable entry and not exceed thebending radius of the flexible and rigid cables.Cat. no. selectionDesignationCat. no.Polybloc distribution block, 3P, 250 A 04033Polybloc distribution block, 4P, 250 A 04034DD380587Horizontally mounted Polybloc in a wall-mount enclosure.Electrical characteristicsThe electrical characteristics are perfectly compatible with the connected devices.Neither the temperature derating curves nor the performance levels of the circuitbreakers and switch-disconnectors are altered.b rated insulation level Ui = 750 Vb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have beentested.impulse withstand voltage Uimp = 8 kV.SupplyDirectly to the terminals of the Compact NS and Interpact INS devices up to 250 A.DistributionVia cables, up to six 10 mm² cables and three 16 mm² cables per phase.InstallationDirectly on the mounting plates of horizontally mounted Compact NS100/250 andInterpact INS250 devices in the enclosures.It can also be mounted downstream of vertically mounted Compact NS100/250 andInterpact INS250 devices in the enclosures. In this case, the Polybloc is mounted ona depth-adjustable modular rail (03002 System G) or (03402 System P).DimensionsH (mm) L (mm) P (mm)Polybloc, 3P 105 138 63Polybloc, 4P 140 138 63DD381406110


DistributionSystem GPolybloc distribution blockDD381403Catalogue numbers35 mm² additional blocks These blocks with screw terminals can be mounted on the 250 A Polybloc forconnection of two 35 mm² cables per phase.DesignationCat. no.35 mm² 3P additional blocks (3 blocks) 0415535 mm² 4P additional blocks (4 blocks) 04156DD381404Additional blocks with a Polybloc distribution block.DD381200DD381392160 A Polybloc distribution block The 160 A Polybloc is made up of individual elements that can be used alone or withothers to make two-pole, three-pole or four-pole distribution blocks.Mounting is very fast. It clips onto a modular rail and is supplied by cables via a tunnelterminal.The connection spring terminals are slanted to facilitate cable entry and bending ofthe flexible and rigid cables.It is supplied with a cover that also guides the cables.Three 160 A Polybloc distribution blocks in the vertical positionon a modular rail, supplied by an NG125.160 A Polybloc distribution block in a front plate cut-out.Cat. no. selectionDesignationCat. no.Polybloc distribution block, 1P, 160 A 04031Sold in sets of 12.Electrical characteristicsb rated insulation level Ui = 750 Vb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations were tested.The electrical characteristics are perfectly compatible with the connected devices.Neither the temperature derating curves nor the performance levels of the circuitbreakers and switch-disconnectors are altered.b impulse withstand voltage Uimp = 8 kV.SupplyDirect to a tunnel terminal, for cables up to 70 mm².DistributionVia cables, up to six 16 mm² cables.InstallationThe blocks clip onto a modular rail.DimensionsDD381394709538111


DistributionSystem G160/630 A multi-stage distributionblockCatalogue numbersPD390659160/630 A four-pole multi-stagedistribution blockThe distribution block can be installed horizontally in the device zone or vertically inthe 300 mm wide duct of wall-mount and floor-standing enclosures.The distribution block is made up of:b two staggered supports made of an insulating materialb four slanted copper bars with holes every 25 mmv 13 threaded M6 holes for outgoersv four 12.2 mm diameter holes to supply the distribution block.It is supplied with:b M6 hardwareb one IPxxB insulating barrier for the front.Cat. no. selectionMulti-stage distri. block Size of bars (mm) Cat. no.160 A Distribloc (40°C) 15 x 5 04052250 A Distribloc (40°C) 20 x 5 04053400 A Distribloc (40°C) 32 x 5 04054630 A Distribloc (40°C) 32 x 8 04055DD381341Electrical characteristicsb rated operational current Ie (40°C):v 160 A for distribution block 04052v 250 A for distribution block 04053v 400 A for distribution block 04054v 630 A for distribution block 04055b rated insulation level Ui = 750 Vb rated short-time withstand current Icw:v 10 kA rms / 1 s for 160 A blockv 13 kA rms / 1 s for 250 A blockv 20 kA rms / 1 s for 400 A blockv 25 kA rms / 1 s for 630 A blockb rated peak withstand current Ipk:v 30 k for 160 A blockv 30 k for 250 A blockv 40 k for 400 A blockv 40 k for 630 A blockb impulse withstand voltage Uimp = 8 kV.Supplyb 16 mm 2 to 50 mm 2 cables with crimped lugsb 20 x 2 mm flexible bars for NS100/160b 20 x 3 mm flexible bars for NS250b 32 x 5 mm flexible bars for NS400b 32 x 8 mm flexible bars for NS630.Distribution13 outgoers per phase, max. 50 mm 2 .Installationb screwed horizontally onto the functional uprights of wall-mount and floor-standingenclosuresb screwed vertically onto the functional uprights of the 300 mm wide ductb screwed to plain or slotted backplate.DD381344DD381342DD381343112


113


DistributionSystem GMulticlip distribution blockCatalogue numbersDD381399PD390660DD381661GeneralCable connection.63/80 A Multiclip distributionblocks04008.04004.For connections, the distribution block uses a proven technique, i.e. spring terminals.Downstream circuits are connected from the front, without screws, to springterminals. Contact pressure does not depend on the operator. It automatically adaptsto the size of the conductor (minimum size = 1mm²). Contacts are insensitive tovibrations and thermal variations.Only one cable (flexible or rigid, without a metal ferrule) can be inserted in a springterminal.Degree of protection: IPxxB.Advantagesb a reliable electrical connection, no maintenance required (tightness guaranteedover time)b the fast connections make phase balancing very easy.b rewiring is very easy if the switchboard is expanded or modified.ApplicationDistribution over half or full rows of modular devices. It is generally supplied by adevice at the head of a group of outgoers (NG125, INS, C60, etc.).Cat. no. selectionDesignationCat. no.80 A Multiclip distribution block, 4P 0400463 A Multiclip distribution block, 4P, 1/2 row 04008Electrical characteristicsb rated insulation level Ui = 500 Vb impulse withstand voltage Uimp = 6 kVb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have beentested.b 63/80 A Multiclip distribution blocks:v 4 mm² cable outgoer: Imax = 32 Av 6 mm² cable outgoer: Imax = 40 Av two 6 mm² cables: Imax = 63 A.SupplyVia tunnel terminals up to 25 mm², generally from a device supplying a group ofoutgoers.The tunnel terminals are positioned to facilitate cable entry and screw tightening.They are designed for cables arriving from the top or bottom.Distributionb for the full-row Multiclip, 4P (04004), each phase offers:v 2 connection points for 6 mm² max. cablev 7 connection points for 4 mm² max. cablethe neutral offers:v 4 connection points for 6 mm² max. cablev 13 connection points for 4mm² max. cableb for the half-row Multiclip, 4P (04008), each phase offers:v 2 connection points for 6 mm² max. cablev 2 connection points for 4 mm² max. cablethe neutral offers:v 4 connection points for 6 mm² max. cablev 4 connection points for 4 mm² max. cableEach connection point can receive a single cable, either flexible or rigid.Installationb clipped onto the rear of modular railb screwed to plain or slotted backplateDD381665DD381664Half-row Multiclip distribution block suppliedby an INS switch-disconnector.Multiclip distribution block supplied by a VigiNG125 circuit breaker.Supplied with 100 mm long bared copper connectionsb for full-row Multiclip (04004):v 2 sets of ten 4 mm² connections + 1 set of six 6 mm² connectionsb for half-row Multiclip (04008):v 1 set of ten 4 mm² connections + 1 set of six 6 mm² connections.114


DistributionSystem GMulticlip distribution blockCatalogue numbersPD390661160/200 A Multiclip distributionblocksApplicationDistribution over full rows of modular devices.The distribution block is generally supplied by busbars in enclosures and cubicles.Cat. no. selectionDesignationCat. no.200 A Multiclip, 2P 04012200 A Multiclip, 3P 04013200 A Multiclip, 4P 04014160 A Multiclip, 4P, 1/2 row 04018DD381672DD381670DD381671Electrical characteristicsb rated insulation level Ui = 750 Vb impulse withstand voltage Uimp = 8 kVb short-circuit withstand current: the reinforced breaking capacity due to cascadingin circuit-breaker combinations is maintained. The worst-case situations have been.b 160/200 A Multiclip distribution blocks:v 10 mm² cable outgoer: Imax = 50 Av two 10 mm² cables: Imax = 63 A.Supplyb direct to terminals:v 50 mm² cables with crimped lugsv 20 x 3 mm flexible barsb from Powerclip insulated busbars in a wall-mount or floor-standing enclosure(04021)b from busbars in the duct of a wall-mount or floor-standing enclosure (04024)b from busbars in the rear of a wall-mount or floor-standing enclosure (04029).Busbar connection04012. Designation Cat. no.Connection between 200 A Multiclip and Powerclip insulated busbars 04021(enclosure)Connection between 200 A Multiclip and busbars in a duct (enclosure) 04024Connection between 200 A Multiclip and rear busbars (enclosure) 0402904013.04014.Distributionb 200 A Multiclip, 2P (04012):v 12 connection points for phase and neutralb 200 A Multiclip, 3P and 4P (04013 and 04014):v 12 connection points for each phasev 18 connection points for the neutralb 160 A Multiclip, 4P, 1/2 row (04018):v 6 connection points for each phasev 9 connection points for the neutralEach connection point can receive a single 10 mm² cable, either flexible or rigid.Installationb clipped onto the rear of modular railb screwed to plain or slotted backplate.Supplied with:b 100 mm long, bared 10 mm² copper connectionsv 200 A Multiclip, 2P, 3P and 4P (04012, 04013 et 04014): 2 sets of 12 connectionsv 160 A Multiclip, 1/2 row (04018): 1 set of 12 connectionsb protection covers for the supply terminals (IPxxB)b the hardware required for the supply terminals.DD381673DD380860DD38067404018.Supply from busbars in the duct of a wallmountor floor-standing enclosure (connection04024).Supply from Powerclip busbars in a wallmountor floor-standing enclosure (connection04021).115


DistributionSystem GTerminal blocks supportCatalogue numbersTerminal-block layoutIn <strong>Prisma</strong> <strong>Plus</strong> wall-mount and floorstandingenclosures, terminal blocks areinstalled:b in a duct, which may be a dedicated zone,totally separate from the devicesb in the device compartment, at the top orbottom.DD381407DD381409Installation in the 300 mm wideductA mounting plate, made up of two supports, is equipped with:b a modular rail for the terminal blocks, that is 1600 mm long, can be cut to lengthand has 6.4 mm holes every 450 mmb an earth bar.The supports have cut-outs that can be used to easily tie down the connection wires.Cat. no. selectionDesignationCat. no.Mounting brackets for terminal block and earth bar 04220Modular rail, L = 1600 mm 04226116


DistributionSystem GTerminal blocks supportCatalogue numbersDD381410Top or bottom installationThe terminal blocks are grouped on a modular rail:b that is depth adjustable (03002)b or mounted at the rear of the switchboard (03004). In this case, it can be raised onsupports or spacers, or turned 45° on special supports.Installation directly on the functional uprightsDesignationCat. no.Depth-adjustable modular rail, L = 432 mm 03002Rear modular rail, L = 432 mm 03004Space required in switchboardMax. cable CSAWidth of terminalblockNo. of verticalmodules requiredCorrespondingplain front plate4 mm² 6 mm 3 03803Depth-adjustable modular device rail. 6 mm² 8 mm 3 0380310 mm² 10 mm 5 0380516 mm² 12 mm 6 03806DD381411Installation of the rail on 45° supportsDesignationCat. no.Two 45° supports for modular rail 03005DD381412Installation of the rail on fixing bracketsDesignationCat. no.Two fixing brackets on functional uprightsH = 15 mm 04206H = 45 mm 04207H = 80 mm 04208DD381413Installation of the rail on hexagonal spacersDesignationCat. no.Set of four M6 hexagonal spacersH = 9 mm 03195H = 23 mm 03196H = 55 mm 03197DD381414Installation on a dedicatedmounting assemblyThis mounting assembly is used to easily install and connect a large number ofterminal blocks in a minimum amount of space. It is particularly useful when a ductis not warranted or cannot be installed.PresentationMounting brackets, fixed to the functional uprights at the top or bottom of theenclosure, is equipped with four 200 mm symmetrical rails. They are installedvertically to facilitate cable running.To facilitate mixing of different size terminal blocks and ensure convenientconnections from the front or the side, the distance between rails and the depth ofeach rail can be adjusted.The assembly has cut-outs that can be used to easily tie down the connection wires.Earth bars, supplied separately, can be installed between the rows of terminal blocksto form different configurations, e.g.:b four sets of terminal blocksb 3 sets of terminal blocks + one or two earth bars (L = 290 mm)The mounting assembly occupies a height of 250 mm, i.e. five 50 mm verticalmodules.Cat. no. selectionDesignationCat. no.Mounting plate with 4 vertical DIN rails for terminal blocks 04223117


DistributionSystem GEarth barsCatalogue numbersPosition of the earth bar in theswitchboardIn <strong>Prisma</strong> <strong>Plus</strong> wall-mount and floorstandingenclosures, the earth bar isinstalled:b in a duct, which may be a dedicated zone,totally separate from the devicesb in the device compartment, at the top orbottom.DD381408DD381560Earth bar04201.04214.PresentationThe earth bar can be:b a bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with a 35mm² tunnel terminal and on which earth blocks with spring terminals can be clippedb an earth bar (200 or 450 mm long), equipped with a 35 mm 2 tunnel terminal andclamps with captive screws.DesignationCat. no.Bare earth bar, 12 x 3 mm with 330 mm of connection space, equipped with 04201a 35 mm² tunnel terminal (for earth blocks with spring terminals)4 earth blocks with 12 x 4 mm² spring terminals (L = 75 mm) 042144 earth blocks with 3 x 16 mm² spring terminals (L = 37 mm) 04215DD38151604215.Earth bar with clampsCat. no.Earth bar with 40 clamps + one 35 mm² terminal (L = 450 mm) 042002 earth bars with 20 clamps + one 35 mm² terminal (L = 200 mm) 0420204200.118


DistributionSystem GEarth barsCatalogue numbersDD381561Top or bottom installationEarth bar mounted on rear of modular railDesignationCat. no.2 supports for earth bar on modular rail 04205Earth bar used:b 450 mm earth bar with clamps or spring terminals in an enclosureb 200 mm earth bar with clamps in the 300 mm wide duct.DD381566Earth bar mounted at rear of enclosureEarth bar used:b 450 mm earth bar with clamps or spring terminals in an enclosureb 200 mm earth bar with clamps in the 300 mm wide duct.DD381562Earth bar mounted on 45° supportsDesignationCat. no.Two 45° supports for modular rail 03005Earth bar used:b 450 mm earth bar with clamps or spring terminals in an enclosureb 200 mm earth bar with clamps in the 300 mm wide duct.DD381563Earth bar mounted on fixing bracketsDesignationCat. no.2 fixing brackets for the earth bar on the functional uprightsH = 15 mm 04206H = 45 mm 04207H = 80 mm 04208Earth bar used:b 450 mm earth bar with clamps or spring terminals in an enclosureb 200 mm earth bar with clamps in the 300 mm wide duct.DD381564Earth bar mounted on hexagonal spacersDesignationCat. no.Set of four M6 hexagonal spacersH = 9 mm 03195H = 23 mm 03196H = 55 mm 03197Earth bar used:b 450 mm earth bar with clamps or spring terminals in an enclosureb 200 mm earth bar with clamps in the 300 mm wide duct.119


DistributionSystem GEarth barsCatalogue numbersDD381565Installation on the sideThe earth bar can be installed vertically on two fixing brackets secured to a functionalupright.This solution saves considerable space in the device zone and avoids the need forthe 300 mm wide duct.Cat. no. selectionDesignationCat. no.2 fixing brackets for the earth bar on the functional uprightsH = 15 mm 04206H = 45 mm 04207H = 80 mm 04208Earth bar used:b earth bar with clamps or spring terminals.DD381358Installation in the 300 mm wideductA mounting plate (04220), made up of two supports, is equipped with:b a 1600 mm modular rail (04226) for terminal blocksb an earth bar.The supports have cut-outs that can be used to easily tie down the connection wires.Cat. no. selectionDesignationCat. no.Mounting plate for terminal block and earth bar 04220Earth bar used:b earth bar with clamps or spring terminals.DD380763Installation on a dedicatedmounting plateThe mounting plate for terminal blocks (04223) can be equipped with two 200 mmearth bars with clamps.DesignationCat. no.Mounting plate with 4 vertical DIN rails for terminal blocks 04223Earth bar used:b 200 mm earth bar with clamps.120


DistributionSystem GNeutral barsCatalogue numbersDD382652Neutral barA neutral bar is created by inserting insulating spacers behind an earth bar.DesignationCat. no.Kit for neutral bar 04210121


DistributionSystem GTerminal blocksSpring technologyCatalogue numbersTerminal blocksTerminal blocks for 4 to 16 v cables, flexible or rigid, without a metal ferrule.b connection to spring terminals, no screwsb contact pressure automatically adapts to the size of the conductorb only one cable can be inserted in a spring terminalb two versions:v 4 - 6 - 10 - 16 v : one incomer and one outgoer for cablesv 4 v : one incomer and two outgoers for cablesb three colours: grey for phases, blue for neutral and green/yellow for earthb mounting by clipping onto a modular railb trated insulation level Ui = 800 Vb rated impulse withstand voltage Uimp = 8 kVAdvantagesb the quality of the connection does not depend on the operator and remains stableover time without maintenanceb contacts are insensitive to vibrations and thermal variations.b less expensive to applyb permits a frontal connectionb connection surety is operator-independentTerminal blocks for 4 v cablesNumber per set Cat. no.6 mm wide1 incomer, 1 outgoerGrey block 2 x 4 v 100 AB1 RR435U2GRBlue block 2 x 4 v 100 AB1 RR435U2BLGreen/yellow block 2 x 4 v 100 AB1 RRTP435U2Partition 10 AB1 RRTPAC242Grey end plate 10 AB1 RRAC443GROne incomer, one outgoers. Blue end plate 10 AB1 RRAC443BL1 incomer, 2 outgoersGrey block 3 x 4 v 100 AB1 RR435U3GRBlue block 3 x 4 v 100 AB1 RR435U3BLGreen/yellow block 3 x 4 v 100 AB1 RRTP435U3Partition 10 AB1 RRTPAC243Jumper 10 AB1 RRAL42Grey end plate 10 AB1 RRAC243GROne incomer, two outgoers.Blue end plate 10 AB1 RRAC243BL815996510050510048Terminal blocks for 6 v cablesNumber per set Cat. no.8 mm wideGrey block 2 x 6 v 100 AB1 RR635U2GRBlue block 2 x 6 v 100 AB1 RR635U2BLGreen/yellow block 2 x 6 v 100 AB1 RRTP635U2Jumper 10 AB1 RRAL6251046Terminal blocks for 10 v cables Number per set Cat. no.10 mm wideGrey block 2 x 10 v 50 AB1 RR1035U2GRBlue block 2 x 10 v 50 AB1 RR1035U2BLGreen/yellow block 2 x 10 v 50 AB1 RRTP1035U2Jumper 10 AB1 RRAL102510045Terminal blocks for 16 v cables12 mm wideNumber per set Cat. no.Grey block 2 x 16 v 50 AB1 RR1635U2GRBlue block 2 x 16 v 50 AB1 RR1635U2BLGreen/yellow block 2 x 16 v 50 AB1 RRTP1635U2Jumper 50 AB1 RRAL162122


DistributionSystem GTerminal blocksScrew technologyMarkersCatalogue numbersTerminal blocksTerminal blocks for 35 to 150 v cables, flexible or rigid, without a metal ferrule.Complementary offer "terminal blocks spring technology" for cables up to 16 v .b two colours: grey for phases, blue for neutralb mounting by clipping onto a modular railb rated insulation level:v Terminal blocks for 35 to 70 v cables: Ui = 800Vv terminal blocks for 150 v cables: Ui = 1000Vb rated impulse withstand voltage:v Terminal blocks for 35 to 150 v cables:Uimp = 8kV501685Terminal blocks for 35 v cables Number per set Cat. no.16 mm wideGrey block 2 x 35 v 20 AB1 VVN3535UBlue block 2 x 35 v 20 AB1 VVN3535UBLPartition plate 10 AB1 ASN35501686Terminal blocks for 70 v cables Number per set Cat. no.24 mm wideGrey block 2 x 70 v 20 AB1 VVN7035UBlue block 2 x 70 v 20 AB1 VVN7035UBLPartition plate 10 AB1 ASN70501687Terminal blocks for 150 v cables Number per set Cat. no.28 mm wideGrey block 2 x 150 v 10 AB1 VVN15035UBlue block 2 x 150 v 10 AB1 VVN15035UBLStop plateStop plate Number per set Cat. no.Plastic end stop 100 4AB1 AB8P35DD382533DD38253412345678910MarkersSold in lots of 25 identical stripsMarking 6 mm pitch 8 mm pitchBlank AB1-BV6 AB1-BV81...10 AB1-B610 AB1-B81011...20 AB1-B620 AB1-B82021...30 AB1-B630 AB1-B83031...40 AB1-B640 AB1-B84041...50 AB1-B650 AB1-B85051...60 AB1-B660 AB1-B86061...70 AB1-B6670 AB1-B87071...80 AB1-B680 AB1-B88081...90 AB1-B690 AB1-B89091...100 AB1-B6100 AB1-B8100L1AB1-B6L1L2AB1-B6L2L3AB1-B6L3+ Red AB1-BV6RP- Blue AB1-BV6BMMarking Number per set Cat. no.Blank clip-on marker(4.5 x 500 AB1-SA18.3mm)Marker strips with numbers 101 to 110, etc. up to 991 à 999.Please consult "Terminal blocks" catalogue, reference number: ART022468123


DistributionSystem GIP30/31/43/55 enclosuresConnection accessoriesCatalogue numbersDD381170Cable-tie supports in IP30 to IP55enclosuresCable tying in wall-mount or floor-standing enclosuresDesignationCat. no.2 cable-tie supports for wall-mount or floor-standing enclosure 08867Cable-tie support adapter 08866Supplied with hardware for mounting on the functional uprights of the enclosure.Cable tying in wall-mount or floor-standing enclosuresDD381171The adapter makes it possible to tie down the cables next to thegland plate and gain one module in height.DD381172Cable tying in the 300 mm wide ductDesignationCat. no.4 cable-tie supports for 300 mm wide ducts 08868Supplied with hardware for mounting on the functional uprights of the duct.Cable tying in a duct.DD381637Captive nutsThe captive nuts clip onto the functional uprights of wall-mount and floor-standingenclosures.They can also be mounted on slotted mounting plates.DesignationCat. no.Set of 20 M6 captive nuts 03194124


125


DistributionSystem GCable runningCable strapsCatalogue numbersDD382588Vertical cable strapsDesignationCat. no.12 cable straps for vertical cables 04264DD382582DD382589Cover for vertical cable strapsDesignationCat. no.2 covers for vertical cable straps L = 1 m 04263DD382583DD382590Horizontal cable strapsDesignationCat. no.12 cable straps for horizontal cables 04239Horizontal cable straps have the same capacity as 60 x 30 mm trunking.DD382584DD382591Cover for horizontal cable strapsDesignationCat. no.4 covers for horizontal cable straps L = 430 mm 04243DD382585DD382592Vertical trunking supportDesignationCat. no.12 vertical trunking supports 04265DD382586DD382593Horizontal trunking supportDD382587DesignationCat. no.12 horizontal trunking supports 04255Trunking installed horizontally on the rear of a modular rail.126


DistributionSystem GCable runningTrunking, accessoriesCatalogue numbersDD381639TrunkingDesignationCat. no.4 horizontal sections, 60 x 30 mm, L = 450 mm (with supports) 04257Vertical trunking, 80 x 60 mm, L = 2000 mm04267(sold in sets of 18)DD381640DD381641Cable trunking for doorsDesignationCable trunking for doors, L = 2000 mm(sold in sets of 30)Adhesive trunking, 30 x 30 mmCat. no.04233DD380863Flexible trunkingDesignationCat. no.Flexible trunking for wiring to door 04235Length = 500 mm, inner diameter = 19mm.DD381644DD381643Terminal block for auxiliariesDesignationCat. no.Disconnectable terminal block for auxiliaries 04228DD380864DD380867Grommets for wiring throughfrontDesignationCat. no.10 grommets for wiring through front 04234DD380865127


Functional unitsSystem GFront plate accessoriesCatalogue numbersDD382537Lead-sealable screwsDesignationCat. no.4 lead-sealable front plate screws 03358DD381597Blanking platesFor modular devicesDesignationCat. no.Blanking strip, H = 46 mm, L = 1000 mm 032204 divisible blanking plates, H = 46 mm, L = 90 mm03221colour: white RAL 9001DD381598For Compact NS100/250 and Interpact INS250Designation1 divisible blanking plates, H = 85 mm, L = 147 mmcolour: white RAL 9001Cat. no.03249DD381721Switchboard identification plateDesignationCat. no.Switchboard identification plate 08900DD381714DD381757Identification labelsLUMIEREClip-on labelsClip-on labelsThe clip-on support is supplied with a paper label and a transparent cover.It clips onto the front plate horizontally or vertically and can be screwed to anysupport (plain door, plain front plate, etc.).Engraving platesSupplied separately, these plates simply replace the paper labels.Cat. no. selectionClip-on label. Designation Cat. no.12 clip-on labels 18 x 35 08913LUMIERE18 x 72 0891525 x 85 0891712 engraving plates 18 x 35 0891418 x 72 0891625 x 85 08918DD381713Engraving plate.128


Functional unitsSystem GFront plate accessoriesEnclosure accessoriesCatalogue numbersDD382606Adhesive labelsThe adhesive label holders are supplied with a paper label and a transparent cover.DesignationCat. no.12 label holders, W = 180 mm H = 24 mm 08905H = 36 mm 0890612 adhesive label holders, W = 432 mm H = 24 mm 08903H = 36 mm 0890412 divisible label holders, W = 650 mm H = 24 mm 08907H = 36 mm 08908DD382607Symbol sheetsEach sheet comprises adhesive symbols that can be positioned on the identificationlabels to immediately identify the type of circuit.Standard symbols:b loads: sockets, lights, heating units, etc.b rooms: bedroom, bathroom, etc.Special symbols:b loads: lightning arrestor, gate, swimming pool, etc.b rooms: technical room, computer room, etc.Cat. no. selectionDesignationStandard symbols. Set of ten symbol sheets standard 13735special 13736Cat. no.DD382608DD382612Special symbols.Symbols on an adhesive label holder.DD382609Earthing braidDesignationCat. no.Earthing braid, 6 mm² 08910Earthing wire, 6 mm² 08911The braid is equipped with a 4 mm diameter lug at one end and a 6 mm diameter lugon the other.It is used to earth:b a door or wicket door with devicesb a front-plate support frame in a cubicle.DD38133808910.DD382610Touch-up accessoriesDesignationCat. no.Touch-up spray paint, colour RAL 9001 08962Touch-up paint brush, colour RAL 9001 08961DD382611Drawing holderDesignationCat. no.Adhesive drawing holder, colour RAL 9001 08963129


EnclosuresSystem GAir-conditioning accessoriesCatalogue numbersDD381703PresentationFront or side fanIn most cases and notably for IP30 switchboards, convection takes place naturallyand does not require fans.However, when the switchboard is installed in temperate environments or when thedegree of protection is high (IP55), ventilation accessories are indispensable. Formore in-depth information on selecting air-conditioning accessories and the thermalmanagement of switchboards, see page 168The switchboard is cooled by drawing in cool external air.PresentationThe set comprises the fan with a grill and a filter.It can be clipped directly on the cut-out front plate.InstallationThese fans are generally installed at the bottom of floor-standing enclosures:b by cutting out a side panelb or on the front, using the front plate with cut-out for a fan.Cat. no. selectionDesignationCat. no.Fan 08987Front plate with cut-out for fan (7 modules) 03890CharacteristicsPower rating: 70 W.Input voltage: 230 V.Noise level: 69 dB.Degree of protection: IP54.Weight: 3 kg.Throughput: 460 m 3 /h.DD381723DD381704Filter for front or side fanPresentationThe grill is supplied with a standard filter that can be replaced or exchanged for a finerfilter.The grill can be clipped directly on the cut-out front plate.InstallationThe grill/filter can be installed:b by cutting out a side panelb or on the front, using the front plate with cut-out for a fan.CharacteristicsDegree of protection: IP54.DesignationCat. no.Grill with filter (supplied with standard filter, maximum throughput = 130 m 3 /h) 089885 standard filters (replacement) 089895 fine filters 08990Front plate with cut-out for fan (7 modules) 03890DD381724130


EnclosuresSystem GAir-conditioning accessoriesCatalogue numbersDD381676Ventilated front plateDesignationCat. no.IP30 ventilated front plate, H = 50 mm (1 module), S = 80 cm² 03891IP30 ventilated front plate, H = 150 mm (3 modules), S = 250 cm² 03895Located at the top and bottom of the switchboard, IP30 ventilated front platesfacilitate natural convection in the switchboard.S is the surface area of the openings.DD381666Heating elementsL N1N2LNDesignation H W D (mm) Cat. no.55 W heating resistor 184 70 60 0899290 W heating resistor 184 70 60 08993250 W heating resistor 180 80 80 08994The resistors can be mounted horizontally or vertically. They prevent condensation,corrosion and superficial leakage currents.They maintain a positive temperature in the enclosures when external temperaturesdrop very low.Characteristicsb aluminium case with finsb turns off at 60°C, turns on at 25-30°C (temperature of the resistor itself)b equipped with a symmetrical rail for rapid mounting (clips on).DD381667DD381573DD38157408994. 08992, 08993.DD381668ThermostatDesignationCat. no.Thermostat 08998Used to control the temperature inside electrical switchboards in conjunction withheating resistors and fans.Setting range: +5°C to +60°C.Input voltage: 230 V.Fixing: clips onto a modular rail.DD381575131


132


Dimensions contentsDimensions 134Pack wall-mount enclosures 134IP30/31/43 wall-mount enclosures 136IP30/31/43 floor-standing enclosures 138IP55 enclosures 140133


DimensionsPack wall-mount enclosuresSystem GDimensionsWall-mount enclosureDoorDD381950DD381951DD381952No. of rows2 3 4 5 6H 480 630 780 930 1080DD381953DD381956Gland platesDD381954134


DimensionsPack wall-mount enclosuresSystem GDimensionsWall mountingDD381955No. of rows2 3 4 5 6H1 396 546 696 846 996H2 546 696 846 996 1146DD380509Depth behind front plateDD381791DD381957DD381958DD381790135


DimensionsIP30/31/43 wall-mount enclosuresSystem GDimensionsWall-mount enclosuresDoorDD381894DD381895DD381897No. of modules6 9 12 15 18 21 24 27H 330 480 630 780 930 1080 1230 1380DD381896DD381898300 mm wide duct DoorDD381901DD381902DD381899DD381900Cable entryDD381903136


DimensionsIP30/31/43 wall-mount enclosuresSystem GDimensionsWall mountingDD381912No. of modules6 9 12 15 18 21 24 27H1 246 396 546 696 846 996 1146 1296H2 430 580 730 880 1030 1180 1330 1480DD380509Depth behind front plateFunctional uprightsModular railDD381904DD381905DD38190603001/03010. 03002/03011.DD381907DD38190803003. 03004.Slotted mounting plateDD381910DD38191103171/03172/03173/03176/03177/03178.03170/03175.137


DimensionsSystem GIP30/31/43 floor-standingenclosuresDimensionsFloor-standing enclosureDoorDD381909DD381895DD381914No. of modules27 30 33H 1530 1680 1830H1 1380 1530 1680DD381896DD381898300 mm wide duct DoorDD381901DD381902DD381915DD381916Top cable entryCable entry for plinthsDD381903DD381917138


DimensionsSystem GIP30/31/43 floor-standingenclosuresDimensionsWall mountingDD381912No. of modules27 30 33H1 1488 1638 1788H2 1580 1730 1880DD380509Fixing to floorDD381918Depth behind front plateFunctional uprightsModular railDD381904DD381905DD38190603001/03010. 03002/03011.DD381907DD38190803003. 03004.Slotted mounting plateDD381910DD38191103171/03172/03173/03176/03177/03178.03170/03175.139


DimensionsIP55 enclosuresSystem GDimensionsEnclosuresDD381726DD381727DD381728Useful depthDD381731DD381733DD381732Gland plates(1) Multifix rail.(2) Recessed slotted mountingplate.(3) Transparent door.(4) Plain door.(5) Front plate.(6) Door.DuctDD381729DD381730No. of modules H1 A B7 425 375 47511 625 575 67515 825 775 87519 1025 975 107523 1225 1175 127527 1425 1375 147533 1725 1675 1775140


DimensionsIP55 enclosuresSystem GDimensionsDoorUseful door surfaceDD381734DD381735DD3817367 to 23 modules.No. of modules C E H7 420 284 45011 620 484 65015 820 684 85019 1020 884 105023 1220 1084 125027 1420 1284 145033 1720 1584 1750DD38173727/33 modules.141


DimensionsIP55 enclosuresSystem GDimensionsEnclosure combinationsDD381738(1) Side panel.Wall structureDD381739DD381740DD381741CanopyDD381742142


DimensionsIP55 enclosuresSystem GDimensionsPartial door with cut-outsSide panels with cut-outsDD381743DD381744DD381745(1) 7 to 23 modules.(2) 27 to 33 modules.7 modules.11 to 33 modules.Functional mounting platesDD381746DD38174808864.08861.DD381749DD38175008863. 08862.143


144


Characteristics contentsStandards 146International electrotechnical standards 146Standards 147Standard IEC 60439-1 148Enclosure standards 149<strong>Prisma</strong> <strong>Plus</strong> tested switchboards 150CE marking 151Electrical characteristics 152Designing connections with flexible bars 152Designing connections y 630 A 154Designing connections with cables 155Enclosure characteristics 156Degree of protection 156Selection of enclosures according to the premises 158Properties of metal enclosures 166Thermal characteristics 168Thermal management of switchboards 168145


StandardsSystem GInternational electrotechnicalstandardsCharacteristicsDD382009IEC international standardsIEC member countriesSouth AfricaGermanyArgentinaAustraliaAustriaBelarusBelgiumBrazilBulgariaCanadaChinaKorea (Rep. of)CroatiaDenmarkEgyptSpainFinlandFranceGreeceHungaryIndiaIranIndonesiaIrelandIsraelItalyNational standardsJapanLuxemburgMalaysiaMexicoNorwayNew ZealandPakistanNetherlandsPolandPortugalRumaniaUnited KingdomRussiaSingaporeSlovakiaSloveniaSwedenSwitzerlandCzech Rep.ThailandTurkeyUkraineUnited StatesYugoslaviaThe IEC (International Electrotechnical Commission) is a worldwide organisation forstandardisation comprising all national electrotechnical committees (IEC NationalCommittees).The object of the IEC is to promote international cooperation on all questionsconcerning standardisation in the electrical and electronic fields.To that end, the IEC publishes International Standards.Their preparation is entrusted to technical committees and any IEC NationalCommittee interested in the subject dealt with may participate in the preparatorywork.In EuropeThe IEC documents are first studied by CENELEC, which establishes:b either a European standard (EN), often identical to the IEC standard, which thenbecomes the applicable national standard in all the member countriesb or, if problems arise, a harmonisation document (HD).Other IEC member countriesEach country is autonomous and can accept the IEC standard as the nationalstandard, with or without modifications.Even though they are IEC members, countries such as Japan and the United Statescontinue to develop their own standardisation systems.Countries without a standardisation systemIt is possible to refer to an IEC standard in the framework of a project.CEI / IECInternational Electrotechnical CommissionCENELECEuropean Committee for Electrotechnical StandardisationUTEUnion Technique de l’Électricité (French electrotechnicalstandardisation organisation)VDEVerband der Elektrotechnik, Elektronik und Informationstechnike.v. (German electrotechnical, electronics and computertechnology standardisation organisation)BSIBritish Standards Institution146


StandardsSystem GStandardsTools for quality assuranceCharacteristicsThe different types of standardsThere are different types of standards, including:b management standardsb installation standardsb product standards.DD381775DD381776Management standardsISO 9004: Quality management system - guidelines for performance improvement.Used in setting up quality management systems.ISO 9001: Quality management system - requirements. Used for certification audits.DD381777Design and manufacture.Switchgear devices.DD381778Switchgear assemblies.Installation.ISO 14004: Environmental management system - major guidelines on the principles.Systems and techniques implemented.ISO 14001: Environmental management system - specification with guidance foruse.A majority of Schneider Electric development centres and factories are certified ISO9001 and ISO 14001.Installation standardsThe set of IEC 60364-X standards defines the main principles and rules on:b assessment of general characteristics of installationsb protectionb selection and erection of equipmentb verification and maintenance of installations.Product standardsThey apply to <strong>LV</strong> switchgear devices or <strong>LV</strong> switchgear assemblies, where thepurpose is to ensure the correct operation and safety of the concerned products.b standards on switchgear devices:v IEC 60947-1: general rulesv IEC 60947-2: circuit breakersv IEC 60947-3: switches and disconnectorsv IEC 60947-4: contactorsv IEC 62208 / EN 50298: empty enclosures.b standards on switchgear assemblies:v IEC 60439-1: general rulesv IEC 60439-2: busbar trunking systemsv IEC 60439-3: distribution boardsv IEC 60439-4: assemblies for construction sitesv IEC 60439-5: power distribution in networks.RegulationsThe regulations in a given country may make certain standards legally binding andmay also create additional safety requirements.Quality assuranceIn addition to providing proof of the conformity of its quality management system, aproduct manufacturer can demonstrate the quality of products by providing proof thattheir design and manufacture comply with the requirements in the applicablestandard.Proof of conformity may be a declaration by the manufacturer or a certificate suppliedby an independent organisation.147


Standards Standard IEC 60439-1System GCharacteristicsAll elements making up the electrical switchboard are concerned.The object of standard IEC 60439-1 is to lay down the definitions and to state theservice conditions, construction requirements, technical characteristics and tests forlow-voltage switchgear and controlgear assemblies (U < 1000 V).The standard defines a low-voltage switchgear and controlgear assembly (theelectrical switchboard) as "a combination of one or more low-voltage switchingdevices together with associated control, measuring, signalling, protective,regulating equipment, etc., completely assembled under the responsibility of themanufacturer with all the internal electrical and mechanical inter-connections andstructural parts".Standard IEC 60439-1 defines tenmandatory testsThe seven type testsThree routine testsThese tests ensure the conformity of the electrical switchboard and are intended tocheck switchboard characteristics.b seven type tests are carried out on typical configurationsb three routine tests are carried out on the completely finished switchboard. Theirpurpose is the check that the characteristics validated by the type tests were notaltered during the manufacturing operations.1 - Temperature-rise limitsThe incoming circuit is loaded to its rated current and each outgoing circuit is loadedwith its rated current multiplied by the rated diversity factor. Once the temperaturehas stabilised, the temperature rise must not exceed the permissible temperaturesfor materials or risk causing burns.2 - Dielectric propertiesThe test voltage is applied between all live parts and the interconnected exposedconductive parts, as well as between each pole and all the other poles connected forthis test to the interconnected exposed conductive parts.b up to 3500 V, 50 Hzb 4 to 12 kV impulse voltage depending on the rated characteristics.3 - Short-circuit withstand strengthIn the event of a short-circuit, whether inside or outside the switchboard, the lattermust handle the resulting stresses (temperature rise, attraction or repulsion forcesexerted on conductors, etc.).The capacity to handle the stresses is above all the means to avoid danger (breakingand projection of components, electric arcs and their propagation outside theswitchboard).However, it is also the means to ensure a rapid return to operation after the incident.4 - Effectiveness of the protective circuitThe effectiveness of the protective circuit is checked by two tests:b short-circuit strength between the protective conductor and the nearest phaseb verification, employing a resistance measuring instrument, of the effectiveconnection between the exposed conductive parts of the assembly and the protectivecircuit.5 - Clearances and creepage distancesThe minimum clearance in air is a function of the impulse withstand voltage and thedegree of pollution in the switchboard.The minimum creepage distance is a function of the rated insulation level, the degreeof pollution and the material group of the insulating material separating the live parts.6 - Mechanical operationSatisfactory mechanical operation is verified after installation in the assembly.The number of operating cycles for the test is 50.This test is required for the locking mechanisms, for example.7 - Degree of protectionThe tests carried out determine the capacity of the switchboard to:b protect people against access to dangerous partsb protect devices against the penetration of foreign objects and liquids.1 - Inspection of the assembly2 - Dielectric test3 - Checking of protective measures and of the electricalcontinuity of the protective circuits.148


StandardsSystem GEnclosure standardsIEC 62208 and EN 50298CharacteristicsStandards IEC 62208 andEN 50298Empty enclosures for low-voltageswitchgear and controlgearassembliesType testsGeneral rules for empty enclosuresStandards IEC 62208 and EN 50298 lay down definitions, classifications,characteristics and test requirements for the enclosures used for assemblies.They apply to empty enclosures before installation of the devices by the panelbuilder, as supplied by the manufacturer.They apply to one-piece enclosures and to enclosures supplied in kit form.1 - Static load2 - Hoisting3 - Axial loads of metal inserts4 - IK code5 - IP code6 - Thermal stability7 - Resistance to heat8 - Resistance to abnormal heat and to fire9 - Dielectric strength10 - Protective-circuit continuity11 - Weather resistance12 - Corrosion resistance13 - Marking.149


Standards<strong>Prisma</strong> <strong>Plus</strong> tested switchboardsSystem GCharacteristicsA switchboard must comply with the requirements in standard IEC 60439-1 toguarantee the safety and reliability of the installation.Managers of installations, fully aware of the professional and legal liabilities weighingon their company and on themselves, demand a high level of safety for the electricalinstallation.What is more, the serious economic consequences of prolonged halts in productionmean that the electrical switchboard must provide excellent continuity of service,whatever the operating conditions.The Schneider Electric solution b specify switchboards that comply with standard IEC 60439-1b guarantee a level of safety that has been 100% tested, from the day theswitchboard is installed and throughout its service lifeb ensure the return on investment through easy upgrading of the installation incompliance with the standardb guarantee that the switchboard complies with the technical specifications.<strong>Prisma</strong> <strong>Plus</strong> tested switchboardsThe conformity of the switchboard has been tested and proven.A <strong>Prisma</strong> <strong>Plus</strong> switchboard is:b made up of Merlin Gerin low-voltage devices and components that all comply withthe applicable standardsb based on configurations in the Merlin Gerin catalogueb made up of <strong>Prisma</strong> <strong>Plus</strong> mechanical and electrical components that have beensubjected to the seven type tests required by the standardb mounted and wired by a panel builder in compliance with professional standardsb subjected to the three routine tests required by the standard.Schneider Electric makes available to the panel builder everything required to createtested <strong>Prisma</strong> <strong>Plus</strong> switchboards, including the basic configurations in the lowvoltagedistribution catalogue, all the documentation for switchboard design andmounting, calculation and design software, etc.The panel builder can easily demonstrate conformity with standard IEC 60439-1 bypresenting the declarations or certificates of conformity concerning the type testscarried out by independent laboratories ( ASEFA, ASTA, KEMA, etc.) and suppliedby Schneider Electric.The panel builder is responsible for the three routine tests and delivers thecorresponding declarations of conformity.150


StandardsCE markingSystem GCharacteristicsCE markingThe CE declaration of conformityProducts marked CECE marking is defined by regulations and attributed under the sole responsibility ofthe manufacturer. It is intended for the verification authorities of the Europeancountries that enforce the European regulations.It allows the free circulation of a product in the European Union and certifies that itcomplies with the basic requirements of all the applicable European directives.CE marking does not attest to quality and does not indicate conformity with astandard.The declaration is intended exclusively for authorities in charge of verifyingcompliance with the applicable regulations and it drafted, signed and held forpresentation to the authorities by the manufacturer.For the <strong>Prisma</strong> <strong>Plus</strong> range, the declaration is the responsibility of the SchneiderElectric unit that designed and developed the product.For <strong>LV</strong> switchboards, the declaration is the responsibility of the panel builder.The following products receive CE marking:b all products that are liable to endanger the safety of persons, animals and property(<strong>LV</strong> directive)b all products that are liable to cause electromagnetic disturbance above astandardised threshold or the performance of which is liable to be affected by suchdisturbance (EMC directive).Consequences:b the <strong>Prisma</strong> <strong>Plus</strong> range of switchboards falls under the <strong>LV</strong> directive onlyb <strong>LV</strong> switchboards are covered by the <strong>LV</strong> directive and may also fall under the EMCdirective, depending on the type of devices incorporated.CE markingeFor the <strong>Prisma</strong> <strong>Plus</strong> range, the CE marking is placed:b on the packing of "mechanical" componentsb on the product itself for "electrical" components.For the <strong>LV</strong> assemblies created by the panel builder, the CE marking is placed:b on the packing materialsb on the name plate (if applicable)b on one of the documents accompanying the switchboard when it is shipped.151


Electrical characteristicsSystem GDesigning connections withflexible barsDevice connectionsCharacteristicsFlexible copper bars with aninsulating sheath<strong>Switchboards</strong> that comply with standard IEC 60439-1It is imperative to use the values indicated below that have been validated for theinstallation of devices in <strong>Prisma</strong> <strong>Plus</strong> switchboards.The parameters determining the size of flexible bars are:b the environment in which the devices are installed:v position in the enclosurev dimensions of other conductors in the circuitv ambient temperature around the switchboardb the characteristics of the connected devices:v device heat lossesv the type of installation (horizontal or vertical)v the type of device (fixed or withdrawable).Only the equipment manufacturer with in-depth knowledge on:b the characteristics of the installed devicesb the configuration of the installation in the enclosurecan provide the correct sizes of flexible bars for a given permissible current.Insulated, flexible bars make for easy, fast and flexible implementation up to 630 A,but higher ratings require sizes that cancel these advantages.For high Isc values, it is advised to use rigid bars which require fewer supports.Better than cables, insulated flexible bars, they offer:b better insulation temperature withstand (125°C for bars, 105°C for cables) and alarger exchange surface for an equivalent size, i.e. a smaller size for a given currentb greater rigidity offering better electrodynamic characteristics for short-circuitcurrentsb no intermediate parts (lugs) for a direct connection between the device and thebusbars therefore less temperature rise and less risk of errorb fast implementation of prefabricated connections already cut to length, formed anddrilled.Technical characteristicsb thickness of the insulation: variable depending on the bar size, 2 mm on averageb rated insulation level Ui = 1000 Vb impulse withstand voltage Uimp = 12 kVb maximum withstand temperature of insulating material = 125°C.Connection In all enclosures with IP y 55b the switchboard internal temperature is 60°Cb the withstand temperature of the insulating material is 125°C.If the withstand temperature of the insulation is only 105°C, use the next largestflexible bar.The bar sizes indicated below take into account the derating curves of devices.Connection of devices and distribution blocks to busbarsDevice INS125 INS160 INS250 INS320INS400INS500INS630NS100 (1) NS160 (1)S (mm) 20 x 2 20 x 2 20 x 3 32 x 5 32 x 6 20 x 2 20 x 3Device NS250 (1) NS400 (1) NS630 INF250ISFT250INF400ISFT400INF630ISFT630S (mm) 20 x 3 32 x 5 32 x 8 24 x 5 32 x 5 32 x 8(1) The values for circuit breakers apply to contactors with the same ratings.To connect a Compact NS250 to Powerclip busbars, use a 24 x 5 mm flexible bar(04746).DeviceMulticlip distributionblock (200 A)Polypact distributionblock (3P)S (mm) 20 x 3 32 x 6 32 x 5Polypact distributionblock (4P)Disconnectors, terminal blocks, connections, busbars tobusbarsI max. (60 °C) 200 A 250 A 400 A 400 A 480 A 520 A 580 A 660 AS (mm) 20 x 2 20 x 3 24 x 5 24 x 5 24 x 6 32 x 5 32 x 6 32 x 8Note: The values indicated above have been validated for <strong>Prisma</strong> <strong>Plus</strong> switchboards.152


Electrical characteristicsSystem GCharacteristicsDesigning connections withflexible barsCompact circuit breakersNS100 to NS630Compact NS100 to NS250Insulated flexible copper barsDevicesIP y 55NS100TMD-TMGNS125TMD-TMGNS160 (1)TMD-TMGNS250 (1)TMD-TMGNS100STRNS160STRNS250 (2)STRPermissible current (A)Ambient temperature around the switchboard25 °C 30 °C 35 °C 40 °C 45 °C 50 °CSize per phase 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2I (A) 100 97.5 95 92.5 90 85Size per phase 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2I (A) 125 122 119 116 113 100Size per phase 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3I (A) 160 156 152 147 144 140Size per phase 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3I (A) 250 244 238 231 225 198Size per phase 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2 20 x 2I (A) 100 100 100 100 100 100Size per phase 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3I (A) 160 160 160 160 160 160Size per phase 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3 20 x 3I (A) 250 250 237.5 237.5 225 225(1) For a withdrawable NS160 or NS250 equipped with a Vigi or an insulation-monitoring module, multiply the In values by 0.9.(2) For a withdrawable NS250 equipped with a Vigi or an insulation-monitoring module, multiply the In values by 0.86.Compact NS400 to NS630Insulated flexible copper barsPermissible current (A)DevicesIP y 55NS400N/H/LfixedNS400N/H/Lwith VigiNS400N/H/LwithdrawableNS630N/H/LfixedNS630N/H/<strong>LV</strong>igi or withdrawablePermissible current (A)Ambient temperature around the switchboard25 °C 30 °C 35 °C 40 °C 45 °C 50 °CSize per phase 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5I (A) 400 400 400 390 380 370Size per phase 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5I (A) 400 390 380 370 360 350Size per phase 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5 32 x 5I (A) 400 390 380 370 360 350Size per phase 32 x 6 32 x 6 32 x 6 32 x 6 32 x 6 32 x 6I (A) 630 615 600 585 570 550Size per phase 32 x 8 32 x 8 32 x 8 32 x 8 32 x 8 32 x 8I (A) 570 550 535 520 505 490Note: The values indicated above have been validated for <strong>Prisma</strong> <strong>Plus</strong> switchboards.153


Electrical characteristicsSystem GCharacteristicsCompact NS100 to NS250Horizontal mountingDesigning connections y 630 AIncoming connection blockand power supply blockon Powerclip busbarDetermining the permissible current of NS100 to NS630 connection and powersupply blocks as a function of the ambient temperature around the switchboard andtheir IP degree of protection.DeviceNS100TMD-TMGPermissible current (A)Ambient temperature around the switchboard25 °C 30 °C 35 °C 40 °C 45 °C 50 °CIP y31IP >31IP y31Incoming connection block via the top 04066 100 95 100 92 100 90 97 87 95 85 92 bvia the bottom 04067Power supply block 04060NS100STR Incoming connection block via the top 04066 100 100 100 97 100 95 100 92 100 90 97 bvia the bottom 04067Power supply block 04060NS160TMD-TMGIncoming connection block via the top 04066 160 152 160 147 160 144 156 140 152 136 147 bvia the bottom 04067Power supply block 04060NS160STR Incoming connection block via the top 04066 160 160 160 156 160 152 160 147 160 144 156 bvia the bottom 04067Power supply block 04060NS250TMD-TMGIncoming connection block via the top 04066 238 213 231 207 225 200 219 193 213 185 207 bvia the bottom 04067Power supply block 04060NS250STR Incoming connection block via the top 04066 250 219 245 213 238 207 225 200 219 193 213 bvia the bottom 04067Power supply block 04060NS400N/H/LfixeNS630N/H/Lfixeb connection not possible.Incoming connection block 04076 400 360 390 350 380 340 370 330 360 320 350 bPower supply block 04070Incoming connection block 04076 570 520 555 505 540 490 525 470 510 450 495 bPower supply block 04071IP >31IP y31IP >31IP y31IP >31IP y31IP >31IP y31IP >31154


Electrical characteristicsSystem GDesigning connections withcablesCharacteristicsCablesPractical guidelinesSchneider Electric provides cabling recommendations according to the rating of thecircuit breaker.The size of cables must be selected according to:b the level of currentb the ambient temperature around the conductorsb the degree of protection for the switchboard.The tables below take into account the installation conditions for each type of device(permissible temperature at connection terminals, etc.).They follow the temperature derating values for installed devices in all enclosureswith cover panels rated IP y 55.b switchboard internal temperature 60°Cb connections using copper cables.For System G, the volumes, ratings and connection lengths are low.Select the values in the "Cables tied together" column, according to the IP.Connection of circuit breakersSize ofcablesPermissible current (A)Cables tied individually Cable tied together(mm²) IP y 31 IP > 31 IP y 31 IP > 311.5 16 14 14 122.5 25 25 22 204 32 29 28 246 40 39 36 3310 63 55 55 5016 90 77 80 7025 110 100 100 9335 135 125 125 12050 180 15070 230 19095 275 230Connection of other devicesSize ofcablesPermissible current (A)Cables tied individually Cable tied together(mm²) IP y 31 IP > 31 IP y 31 IP > 311.5 13 12 12 102.5 23 21 20 194 28 26 25 226 36 35 32 3010 55 50 50 4616 80 70 72 6325 100 90 90 8435 120 115 110 10350 165 13570 210 17695 250 210Connection of NS100 to 630 A Device NS100 NS160 NS250Size (mm²) 25 50 95Note: .Schneider Electric recommends connecting NS400/630 circuit breakers with insulatedflexible bars or rigid bars.see page 152.Note: The values indicated above have been validated for <strong>Prisma</strong> <strong>Plus</strong> switchboards.155


Enclosure characteristicsSystem GDegree of protectionGeneralCharacteristicsStandard IEC 60364-5-51 listed and codified a large number of externalinfluences to which electrical installations can be subjected, including thepresence of water, solid objects, shocks, vibrations, corrosive substances,etc.Degree of protection IPStandard IEC 60529 (IP code, February 2001) indicates the degrees of protectionprovided by an enclosure for electrical devices against access to hazardous parts,against penetration of solid foreign objects and against penetration of water.These standards do not apply for the protection against the risks of explosion orconditions such a humidity, corrosive vapour, fungus or vermin.The IP code is made up of two characteristic numerals and can include an additionalletter when the actual protection for persons against access to the hazardous partsis better than that indicated by the first numeral.The first numeral characterises the protection provided against the ingress of solidforeign objects and the protection of persons.The second numeral characterises the protection provided against the ingress ofwater with harmful effects.11 st numeral 2 nd numeralProtection of personsProtection against ingress of solidobjectsProtection against ingress of waterProtected againstaccess with back ofhandDD381959Protected againstsolid foreign objectslarger than 50 mmDD3819591Protected againstvertically falling waterdrops (condensation)DD3819662Protected againstaccess with a fingerDD381960Protected againstsolid foreign objectslarger than 12.5 mmDD3819632Protected againstvertically falling waterdrops when enclosuretilted up to 15°DD3819673Protected againstaccess with a toolDD381961Protected againstsolid foreign objectslarger than 2.5 mmDD3819613Protected againstspraying water up to60° from verticalDD3819684Protected againstaccess with a wireDD381962Protected againstsolid foreign objectslarger than 1 mmDD3819624Protected againstsplashing water fromall directionsDD3819695Protected againstaccess with a wireDD381962Protected against dust(dust protected)DD3819645Protected againstwater jets from alldirectionsDD3819706Protected againstaccess with a wireDD381962Dust tightDD3819656Protected againstpowerful water jetsfrom all directionsDD3819717Protected against theeffects of temporaryimmersion in waterDD3819728Protected against theeffects of continuousimmersion in waterDD381973156


Enclosure characteristicsSystem GDegree of protectionGeneralCharacteristicsAdditional letter (optional)Protection of persons against access to hazardous parts.DesignationProtectionABCDProtected against access with back of handProtected against access with a fingerProtected against access with a toolProtected against access with a wireThe additional letter is used only if the actual protection of persons is higher than thatindicated by the first characteristic numeral of the IP code.If only the protection of persons is of interest, the two characteristic numerals arereplaced by "X", e.g. IPxxB.ExampleProtected against solid foreign objectslarger than 2.5 mmIP30DNo protectionProtected against access witha tool 1 mm in diameterRemarks on the degree ofprotection IPDegree of protection againstmechanical impacts IKb the degree of protection IP must always be read and understood numeral bynumeral and not as a whole.For example, an IP31 wall-mount enclosure is suitable for an environment thatrequires a minimum degree of protection IP21. But an IP30 wall-mount enclosure isnot suitable.b the degrees of protection indicated in this catalogue are valid for the enclosures aspresented. However, the indicated degree of protection is guaranteed only when theinstallation and device mounting are carried out in accordance with professionalstandards.Standard IEC 62262 defines an IK code characterising the capacity of products toresist mechanical impacts from all sides.IK codeImpact energy (joules)01 0.1402 0.203 0.3504 0.505 0.706 107 208 509 1010 20RecommendationIn terms of the risks of impacts, selection of the IK code can be summed up asindicated below.SiteRecommended IKNo risk of major impact Technical rooms 07Significant risk of impact that Hallways08 (switchboard with door)can damage devicesMaximum risk of impact that candamage the switchboardWorkshops 10157


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsThe IP and IK degrees of protection provided by an enclosure must be specified asa function of the various external influences defined by standard IEC 30364-5-51, inparticular:b presence of foreign solid bodies (code AE)b presence of water (code AD)b mechanical stress (code not specified)b capability of persons (code BA)b ....<strong>Prisma</strong> <strong>Plus</strong> switchboards are designed for indoor installation.Unless the rules, standards and regulations of a specific country stipulate otherwise,Schneider Electric recommends the following IP and IK values based on Frenchguide UTE C 15-103 (November 1997).Using the table1 Opposite the relevant premises, read the recommended IP and IK values.2 The b symbol indicates the enclosure or cubicle satisfying the criteria of the UTEguide.Any enclosure or cubicle with a higher degree of protection can also be used.3 If several degrees of protection are possible (refer to the standard for more details)and the v and b symbols are indicated (e.g. 24 v /25 b ), enclosures that correspondto the higher degree of protection (b) are suitable for the lower degree ofprotection (v).Example:Selection of an enclosure for a laundry room.Minimum degree of protection: IP23/IK02A wall-mount enclosure with a door (plain or transparent), a canopy and a gasketoffer IP43/IK08 degrees of protection and are therefore suitable for this application.Type of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy+ gasketFloor-standingenclosureMin. IP/IKrequiredIP IKwithout door with door with door + canopy with door + canopy+ gasketIP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10Domestic or comparable premises or locationsPorch 24 07 bBathrooms (see washrooms)Bicycles, motorcycles, tricycles, etc. 20 07 b(premises for)Water, sewer and heating23 02 bconnectionsLaundries 23 02 bCellars, garages, furnace rooms 20 02 v /07 b bBedrooms 20 02 bTrash rooms 25 07 bHalls in cellars 20 07 bCourtyards 24 v /25 b 02 v /07 b bKitchens 20 02 bShower rooms (see washrooms)Indoor stairways and alleys 20 02 v /07 b bOutdoor stairways and outdoor alleys 24 07 bwithout roofsOutdoor alleys with roofs 21 02 bAttics (roof space) 20 02 bGarden shelters 24 v /25 b 02 v /07 b bLatrines 20 02 bDustbin rooms 25 02 v /07 b bIroning room 21 02 bAccess ramps to garages 25 07 bIP55158


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsType of premisesWashrooms, roomscontaining a bathtub orshowerEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy IP55+ gasketFloor-standingenclosure without door with door with door + canopy with door + canopy+ gasketDegré IP/IK min IP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10requisIP IKvolume 0 27 02volume 1 24 02 bvolume 2 23 02 bvolume 3 21 02 bLounges, living rooms, etc 20 02 bDrying rooms 21 02 bBasements 21 02 v /07 b bCovered terraces 21 02 bWCs 21 02 bVerandas 21 02 bCrawl spaces 23 02 v /07 b bCommercial premises and adjoining areasGunsmiths (storage area, workshop) 31 v /33 b 08 bLaundries (wash room) 24 07 bButchers shop 24 07 bcold room23 07 by -10 °CBakers, cake shops (kitchens) 50 07 bCoffee roasters 21 02 bCoal, wood, oil 20 08 bDelicatessen (production) 24 07 bSweets (production) 20 02 bShoe repair shops 20 02 bDairies 24 02 bHardware stores (storage areas for 33 07 bchemicals and paint)Wood workers 50 07 bArt galleries 20 02 v /07 b bFlorists 24 07Furriers 20 07 bFruit and vegetable merchants 24 07 bGrain shops 50 07 bBookshops, stationers 20 02 bMotorcycle and bicycle repairs and 20 08 baccessoriesMessenger services 20 08 bFurniture shops (antiques, secondhand)20 07 bGlass and mirror merchants 20 07 b(workshop)Wallpaper shop (storage area) 21 07 bCosmetics shop (storage area) 31 02 bChemists (storage area) 20 02 bPhotographers (dark room) 23 02 bPlumbers (storage area) 20 07 bFishmongers 25 07 bDry cleaners 23 02 bHardware stores (without paint, 20 07 bchemicals, etc.)Locksmiths 20 07 v /08 b v bVintners, spirits (cellars and storage 23 07 barea)Interior decorator (carding) 50 07 bTailors, clothing retailers (storage 20 02 barea)Pet care 35 07 b159


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsType of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy IP55+ gasketFloor-standingenclosure without door with door with door + canopy with door + canopy+ gasketDegré IP/IK min IP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10requisIP IKBuildings open to the general publicL Lecture halls, halls 20 02 v /07 b bmeeting rooms, stage areas 20 08 bauditoriums,scenery storage 20 08 bhalls used forroomsseveral purposescostume rooms 20 07 bMRetail premises,shopping mallssales premises 20 08 bareas for storageand handling ofpacking20 08 bN Restaurants and cafes 20 08 bO Hotels and boarding houses 20 02 bP Dance halls and gaming parlours 20 07 bRTeachingestablishments,holiday campsclassrooms 20 02 bdormitories 20 08 bS Libraries and documentation centres20 02 bT Exhibitions halls and rooms 21 02 bareas for reception 20 07 bof equipmentand merchandiseU Healthcare bedrooms 20 02 bestablishments incineration 21 07 v /08 b boperating rooms 20 07 bcentralised24 02 v /07 b bsterilisationpharmacies and labs 21 v /23 b 02 v /07 b v bwith more than 10 l ofinflammable liquidsV Places of worship 20 02 bW Administrative premises, banks 20 02 bX Indoor sports halls 21 07 v /08 b bfacilities premises containing 21 08 brefrigeration facilitiesY Museums 20 02 bPA Open air facilities 25 08 v /10 b bCTS Marquees and tents 44 08 bSG Inflatable structures 44 08 bPS Covered parking lots 21 08 v /10 b v bShared premises ofbuildings open to thegeneral publicstorage rooms 20 08 bpacking rooms 20 08 barchive rooms 20 02 bfilm and magnetic 20 02 bmedia storagelinen rooms 21 02 blaundry rooms 24 07 bmisc. shops 21 07 v /08 b bkitchens (large)160


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsbType of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy IP55+ gasketFloor-standingenclosure without door with door with door + canopy with door + canopy+ gasketDegré IP/IK min IP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10requisIP IKTechnical premisesBattery rooms 23 02 v /07 b bLifts (machine rooms and pulley 20 02 v /08 b v brooms)Electrical rooms 20 07 bControl rooms 20 02 bWorkshops 21 v /23 b 07 v /08 b v bLaboratories 21 v /23 b 02 v /07 b v bAir conditioning washers 24 07 bGarages (used exclusively21 07of an area not exceeding 100 m 2for parking vehicles)Machine rooms 31 07 v /08 b bWater pressurisers 23 07 v /08 bBoiler houses and adjoining premises (power in excess of 70 kW)Boiler rooms coal fuel 51 v /61 b 07 v /08 b vother fuel 21 07 v /08 b belectrical 21 07 v /08 b bFuelstorage areascoal 50 v /60 b 08 voil 20 07 v /08 b v bliquefied gas 20 07 v /08 b v bCinder tips 50 v /60 b 08 vPump rooms 23 07 v /08 b bPressure reduction rooms (gas) 20 07 v /08 b v bSteam or hot water facilities 23 07 v /08 b bExpansion vessel rooms 21 02 bGarages and car parks of an area exceeding 100 m 2Parking lots 21 07 v /10 b v bCarwash areas (inside premises) 25 07 bSafety areas indoors 21 07 bLubrication areas 23 08 bBattery recharging areas 23 07 bWorkshops 21 08 bPublic building (other than for the general public)Offices 20 02 bLibraries 20 02 bArchives 20 02 bComputer rooms 20 02 bDesign offices 20 02 bRooms containing reprographic 20 02 bmachinesSorting rooms 20 07 bRefectories in restaurants or 21 07 bcanteensLarge kitchensSports rooms 21 07 v /08 b bBarracks 21 07 bMeeting rooms 20 02 bWaiting rooms, lounges, halls 20 02 bMedical consulting rooms, not fitted 20 02 bwith specific equipmentDemonstrationand exhibition rooms20 02 v /07 b b161


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsType of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy IP55+ gasketFloor-standingenclosure without door with door with door + canopy with door + canopy+ gasketDegré IP/IK min IP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10requisIP IKFarm premises or locationsAlcohol (storage) 23 07 bClosed cattle sheds 35 07 bLaundries 24 07 bWood storage rooms 30 10 bThreshing floors 50 07 bDistilling cellars 23 07 bVat rooms (wine) 23 07 bCourtyards 35 07 bPoultry barns 35 07 bStables 35 07 bFertiliser (storage) 50 07 bStables 35 07 bManure heaps 24 07 bHaylofts 50 07 bHaystacks, forage (storage) 50 07 bGranaries, barns 50 07 bStraw (storage) 50 07 bGreenhouses 23 07 bGrain silos 50 07 bMilking rooms 35 07 bPig sties 35 07 bChicken houses 35 07 bMiscellaneous installationsFair facilities 33 08 bWater treatment facilities 24 v /25 b 07 v /08 b bThermodynamic installations, air-conditioned rooms and cold roomsHeightabovegroundfrom 0 to 1.10 m 25 07 bfrom 1.10 to 2 m 24 07 babove 2 m under 21 07 bevaporator or waterdrain pipeceiling and up to 10cm underneath23 07 bTemperature y -10 °C 23 07 bCompressor room 21 08 bintegral unit locatedoutside or on a terrace34 08 b162


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsType of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy+ gasketFloor-standingenclosureDegré IP/IK minrequisIP IKwithout door with door with door + canopy with door + canopy+ gasketIP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10Industrial facilitiesSlaughter houses 55 08 bBatteries (manufacture) 33 07 bAcid (manufacture and storage) 33 07 bAlcohol (manufacture and storage) 33 07 bAluminium (manufacture and 51 v /53 b 08 bstorage)Livestock (raising, fattening and sale) 45 07 bAsphalt and bitumen storage 53 07 bWool beating and carding 50 08 bIndustrial laundry 23 v /24 b 07 v bWood (processing) 50 08 bMeat packers 24 v 25 b 07 bBakeries 50 07 bBreweries 24 07 bBrickworks 53 v /54 b 08 bRubber (production and processing) 54 07 bCarbide (manufacture and storage) 51 07 bAmmunition factories 53 08 bCarton board (production) 33 07 bQuarries 55 08 bCelluloid (manufacture of objects) 30 08 bCellulose (manufacture) 34 08 bCoal (depots) 53 08 bPork products 53 v /25 b 07 bBoiler-making works 30 08 bLime kilns 50 08 bRag (storage) 30 07 bChlorine (manufacture and storage) 33 07 bChrome-plating 33 07 bCement works 50 08 bCoking plant 53 08 bAdhesives (production) 33 07 bBottling lines 35 08 bLiquid fuels (storage) 31 v /33 b 08 v bFats (processing) 51 07 bLeather (tanning and storage) 31 08 bCopper (ore processing) 31 08 bPaint stripping 54 08 bDetergents (manufacture) 53 05 bDistilleries 33 05 bElectrolysis 33 08 bInk manufacturing 31 05 bFertilisers (manufacture and storage) 55 05 bExplosives (manufacture and 55 08 bstorage)Iron (production and processing) 51 08 bSpinning mills 50 05 bFurriers (beating process) 50 05 bCheese factories 25 05 bGas (production and storage) 31 08 btar (processing) 33 05 bSeed production 50 05 bMetal engraving 33 05 bOils (extraction) 31 05 bPetroleum products (manufacture) 33 v /34 b 08 v bPrintworks 20 08 bIP55163


Enclosure characteristicsSystem GSelection of enclosures accordingto the premisesCharacteristicsType of premisesEnclosure or cubicleWall-mountenclosure without door with door with door + canopy with door + canopy+ gasketFloor-standingenclosureDegré IP/IK minrequisIP IKwithout door with door with door + canopy with door + canopy+ gasketIP30/IK07 IP30/IK08 IP31/IK08 IP43/IK08 IP55/IK10Industrial establishments (continued)Dairies 25 05 bPublic wash-houses 25 05 bLiqueurs (production) 21 05 bHalogenated liquids (use) 21 08 bInflammable products21 08 b(storage and workshops where theyare used)Magnesium (production, storage and 31 08 buse)Machine rooms 20 08 bPlastics (production) 51 08 bCabinet makers 50 08 bMetals (processing) 31 v /33 b 08 v bCombustion engines (testing of) 30 08 bAmmunition storage 33 08 bNickel (ore processing) 33 08 bHousehold waste (processing) 53 v /54 b 07 bPaper (production) 33 v /34 b 07 v bPaper (storage) 31 07 bPerfume (production and storage) 31 07 bPulp mill 34 v /35 b 07 bPaint (production and storage) 33 08 bPlaster (processing and storage) 50 07 bGunpowder factory 55 08 bChemicals (production) 30 v /50 b 08 v bOil refineries 34 v /35 b 07 bSalt preserve factories 33 07 bSoap (production) 31 07 bSaw mills 50 08 bMetalwork shops 30 08 bGrain or sugar silos 50 07 bSilk and artificial hair factories 50 08 bSodium carbonate (processing and 33 07 bstorage)Sulphur (processing) 51 07 bSpirits (storage) 33 07 bSugar mills 55 07 bTanners 35 07 bDye works 35 07 bTextile and fabric (production) 51 08 bVarnish (production and application) 33 08 bGlass works 33 08 bZinc works 31 08 bIP55164


165


Enclosure characteristicsProperties of metal enclosuresSystem GCharacteristicsMerlin Gerin enclosures comply with standard EN 50298 for empty enclosures.The sheet metal used for Merlin Gerin enclosures receives an anti-corrosion epoxyelectrophoresis treatment and a coating of a thermosetting, polyester-resin-modifiedepoxy powder for colour and appearance.This two-coat system provides excellent finish and corrosion protection.The characteristics of this coating are much better than those of traditional epoxypowders:b improved colour stabilityb wider operating temperature range.Mechanical properties ofenclosuresMechanical properties of powdercoated surfacesStatic load on doors, wall-mount and floor-standing enclosuresFloor-standing enclosure64 kgWall-mount enclosure48 kgFloor-standing enclosure door4 kgWall-mount enclosure door4 kgTest conditionsTest piece made of 1 mm thick steel sheet, degreased, iron phosphated, finalrinsing with 100000 Ω cm DI water, 15 microns of anti-corrosionelectrophoresis treatment and 35 microns of powder paint.Adhesion (cross-hatch and pull-off) class 0 required (ISO 2409))Impact strength (1) > 1 kg/50 cm (ISO 6272)Mandrel bending test (2) < 10 mm (ISO 6860)Persoz hardness 300 s (ISO 1522)(1) No cracking of the paint film after dropping a weight of one kilogram on the test piece from aheight of 50 centimetres.(2) Film cracks over a length of 10 millimetres maximum.Artificial ageing test on powdercoatingTest conditions:Two tests carried out on the same 1 mm thick steel sheet test piece.b cyclical damp-heat test:v as per standard IEC 68-2-30- six 24-hour cycles at temperatures higher than 40°Cb continuous resistance to neutral salt mist:v the tests were carried out over a period of 400 hours, far more than the 48 hoursrequired by the standard for indoor installationsv as per standard IEC 68-2-11 and ISO 7253- 400 hours without blistering for normal surface on test piece- 250 hours for a scratched surface.Evaluation of corrosion as per ISO 4628:b adhesion: class y 1b blistering: degree 1 dim.1b rusting: Ri 1b cracking: class 1b flaking imp. 1 dim. 1propagation of corrosion under scratch with respect to the scratch axis: 3 mm max.166


Enclosure characteristicsProperties of metal enclosuresSystem GCharacteristicsChemical properties of powdercoatingTests carried out at ambient temperature on phosphated test pieces coatedwith a 150 to 200 micron film.Test duration (months) 2 4 6 8 10 12AcidsConcentrationAcetic 20 %Sulphuric 30 %Nitric 30 %Phosphoric 30 %Hydrochloric 30 %Lactic 10 %Citric 10 %Bases Soda 10 %Ammonia 10 %Water Distilled waterSeawaterTap waterDiluted bleachSolvents PetrolHigh alcoholsAliphaticsAromaticsKetones, estersTri-perchlorethyleneFilm intact.Film damaged (blisters, yellowing, loss of shine).167


Thermal characteristicsSystem GThermal managementof switchboardsGeneralCharacteristicsA switchboard is designed for operation under normal ambient conditions.Most devices do not operation correctly outside a temperature range of -10 and+70°C.It is therefore important to maintain the switchboard internal temperature within thistemperature range by:b correctly sizing the switchboard during designb correcting the temperature using suitable means.Management of the internaltemperatureCoolingThere are a number of way to dissipate heat from the switchboard.The drawings below present the various means.ConvectionForced-air ventilationDD381484DD381483DD381482DD381481IP > 31 IP y 31 IP y 54 IP y 54Ensured naturally in <strong>Prisma</strong> <strong>Plus</strong>enclosuresUsing fans, it significantly increases thethermal capacity of an enclosure.Forced-airventilation withair-air exchangerForcedconvection andcoolingDD381920DD381921IP > 31 IP > 31On special request.For these extreme cases, many installers prefer to set up the switchboards with otherelectrotechnical and electronic devices in air-conditioned electrical rooms.HeatingThe means employed to raise the internal temperature in a switchboard is a resistorbasedheater, used to:b avoid condensation by limiting variations in temperatureb ensure that the switchboard does not freeze.168


Thermal characteristicsSystem GThermal managementof switchboardsGeneralCharacteristicsCalculation of the internaltemperatureCalculation of the temperature is the means to check that the enclosure canevacuate the dissipated power of the installed devices.Important noteCorrect thermal management of the switchboard depends on compliance withthe installation requirements for the distribution system (power circuits).Incorrect installation will have major consequences on the connected device, butalmost none on the internal temperature of the enclosure.Once the circuit has been correctly sized, it is necessary to check whether theassembly (devices + distribution system + cables) have a level of dissipated powerP(W) y the P(W) that the enclosure can handle.DD381401Method defined by IEC 890 technical reportThis IEC guide for switchboards proposes a calculation method to determine threelevels of internal temperature, depending on the dissipated power of the devices anddistribution blocks installed in the switchboard.Users can consult this document when it is necessary to determine precisely theinternal temperature in view of optimising the switchboard.On request, Schneider Electric can carry out a thermal study to check that theinstalled assembly and the thermal capacity of the enclosure are compatible.DD381350Comparative methodA number of qualified and tested configurations serve as the basis for indicating thethermal capacity of <strong>Prisma</strong> <strong>Plus</strong> enclosures.This is en empirical means to check whether the dissipated power of the desiredconfiguration is close to that of a tested configuration.DD382422Method using charts taking into account enclosure characteristicsTo speed up calculations, Schneider Electric produces charts based on thecompany's experience and a number of assumptions on the installation.They can be used sufficiently precisely to determine the variations in temperatureand the dissipated-power levels for the different types of wall-mount enclosures,floor-standing enclosures and cubicles.For details on the calculation of the dissipated power in the device zone, seepage 173.169


Thermal characteristicsSystem GThermal managementof switchboardsComparative methodCharacteristicsComparative methodPack enclosure, 3 rows, IP30Diversity factor: 0.7Ambient temperature around the switchboard: 35°CP(W) = 95 WDD381766You will have no problems with your switchboard if:b the volume of the enclosure is greater than that of the tested enclosure with asimilar assemblyb the P(W) of the installed assembly is less than the P(W) of the tested configurationin the same size enclosure.For details on the calculation of the dissipated power in the device zone, seepage 173.Wall-mount enclosure, 23 modules, IP30Diversity factor: 0.7Ambient temperature around the switchboard: 35°CP(W) = 170 WDD381786170


Thermal characteristicsSystem GThermal managementof switchboardsComparative methodCharacteristicsComparative methodWall-mount enclosure, 23 modules, plain door, IP30Diversity factor: 0.7Ambient temperature around the switchboard: 35°CP(W) = 200 WDD382418You will have no problems with your switchboard if:b the volume of the enclosure is greater than that of the tested enclosure with asimilar assemblyb the P(W) of the installed assembly is less than the P(W) of the tested configurationin the same size enclosure.For details on the calculation of the dissipated power in the device zone, seepage 173.Floor-standing enclosure, 33 modules, IP30Diversity factor: 0.7Ambient temperature around the switchboard: 35°CP(W) = 270 WDD382419171


Thermal characteristicsSystem GThermal managementof switchboardsComparative methodCharacteristicsTwo cubicles with busbar compartment, 800 mmwide, 1000 mm deep, two 300 mm wide ducts, IP30Diversity factor: 0.7Ambient temperature around the switchboard: 35°CCubicle 1 : P(W) of device zone = 580 WCubicle 2 : P(W) of device zone = 180 WDD382421Application of the diversity factor In the configuration below, the standardised diversity factor (K div.) for a total of 14outgoing circuits is 0.6, i.e. 60 % of In for each outgoing circuit.Merlin Gerin prefers a more conservative approach and therefore divides theinstallation into four main circuits:b NS250b 200 A Multiclip: 8 outgoers V K div. = 0.7b Polypact: 4 outgoers V K div. = 0.8b NS400.1 NS250 + 1 Multiclip 200 A + 1 Polypact + 1 NS400 V 4 outgoers, i.e. a diversityfactor of 0.8.As a result, the current flowing in each circuit is at least 70% and up to 80% of In.Calculation of the power dissipated bydevices in the incoming cubicleDissipated power of the NT1600 indicated by the manufacturer: 460 W.The power dissipated by the connections is approximately 30% of the device P(W):0.3 x 460 = 138 W.Power of circuit breaker + connections = 460 + 138 = 598 W at 1600 A.For I² (the Watts are proportional to the square of the current) at 1410 A (In of theincoming device):598-------------- × 1410 2 405 W1600 2 =Dissipated power of the NS250 indicated by the manufacturer: 42 W.Dissipated power of the connections: 0.3 x 42 = 12.6 W.Power of circuit breaker + connections = 42 +12.6 = 54.6 W at 250 A.For 200 A (the tested value):54,6----------- × 200 2 = 35 W250 2Dissipated power of the Polypact and its four NS250 circuit breakers:4 x 35 W (same calculation as above) = 140 WSum of the dissipated power in the incoming cubicle:P(W) = 405 + 35 +140 = 580 W172


Thermal characteristicsSystem GThermal managementof switchboardsExampleCharacteristicsOnce the dissipated power of the devices has been determined and the enclosurewith its IP selected, transfer the results (sum of the dissipated power and width of thedevice zone) to the chart corresponding to the enclosure IP.DD382423Draw a line parallel to the others on the chart and read the corresponding differencein temperature.For the given example, the heat rise is 22°C at mid-height in the enclosure.The internal temperature= external temperature + heat rise= 35°C + 22°C = 57°C57°C < 60°C stipulated by the standard, i.e. the result is acceptable for an IP3cubicle.This gives roughly:Internal temperature = 60°C at mid-height in the enclosure for a low IP value.Internal temperature = 70°C at mid-height in the enclosure for a high IP value.173


Thermal characteristicsSystem GThermal managementof switchboardsChartsCharacteristicsQuick calculation chartsfor internal temperaturesfor System GFor the enclosures not mentioned on the previouspages, use the equation:P∆T = -------------S × Kwhere:∆T: internal temperature - external temperatureP: power dissipated by the devices, connections andbusbars (in Watts)S: total free surface area of the enclosure(expressed in m 2 )K: thermal-conduction coefficient of the material(W/m 2 °C)K = 5.5 W/m 2 °C for painted sheet metal.DD382432DD382433IP3X wall-mount enclosureIP43 wall-mount enclosureTest conditions:600 mm wide enclosuremounted directly on wallwithout fixing lugs.Test conditions:600 mm wide enclosuremounted directly on wallwithout fixing lugs.Note: The dissipated power of each device is provided by themanufacturer. Add approximately 30% to account for theconnections and the busbars.The indicated internal heat rise is that measured at midheightin the enclosure.DD382434IP3X floor-standing enclosureTest conditions:600 mm wide enclosureon floor against a wall.DD382435IP43 floor-standing enclosureTest conditions:Mounted on wall withfixing lugs or onmounting uprights.DD382436IP55 wall-mount and floor-standing enclosuresTest conditions:600 mm wide enclosuremounted directly on wallwithout fixing lugs ormounting uprights.174


Thermal characteristicsSystem GThermal managementof switchboardsVentilationCharacteristicsSwitchboard ventilationThe air enters the lower section via the fans and exits the upper section:b through a ventilated roofb or through a ventilation opening.The air throughput of the fans is determined by the equation:PD = 31 × • ------- – K S⎝⎛ ∆T ⎠⎞The chart below can be used to determine the necessary throughput, based on thedissipated power, the difference in temperature (internal - external) and the exposedsurface area of the enclosure.ExampleConsider an IP3X cubicle, 650 mm wide and 400 mm deep, containing components(devices, connections, busbars, etc.) dissipating 1000 W.The ambient temperature around the cubicle is 50°C.Given that the average temperature at mid-height should not exceed 60°C, thedifference in temperature ∆T is equal to 60 - 50 = 10°C.The exposed surface of the cubicle (non adjacent to a wall or other cubicle)is 4.46 m².(back = 1.3 m², front = 1.3 m², roof = 0.26 m², side panels = 1.6 m²).What is the necessary throughput of the ventilation system?The throughput can be calculated as:D=100031 • ------------ 5• 5⎝– ×10446•⎠D = 234 m 3 /h.In the range of <strong>Prisma</strong> <strong>Plus</strong> accessories, select a system with a throughputof 300 m 3 /h.DD381391Calculation dataP : power dissipated by the devices, connections and busbars (in Watts)P r : power of the heating resistor (in Watts)T m : maximum internal temperature in the device zone (in °C)T i : average internal temperature (in °C)T e : average external temperature (in °C)∆T m =T m – T e∆T =T i–T eS : total free surface area of the enclosure (expressed in m 2 )K : thermal-conduction coefficient of the material (W/m 2 °C)K = 5.5 W/m 2 °C for painted sheet metalD: ventilation throughput (in m 3 /h)Note: The dissipated power of each device is provided by the manufacturer.Add approximately 30% to account for the connections and the busbars.175


Thermal characteristicsSystem GThermal managementof switchboardsHeatingCharacteristicsSwitchboard heatingThe heating resistor, placed in the bottom of the switchboard, maintains the internaltemperature 10°C higher than the external temperature. When the switchboard is notin operation, the heater compensates the dissipated power normally emitted by theswitchboard.The power of the heating resistor is calculated:b using the equation: Pr = (∆T xSxK) -Pb or using the charts below, based on the exposed surface area of the enclosure andthe desired difference in temperature.Chart to determine the heating resistor for small wall-mount enclosures(exposed surfaces y 1 m 2 )DD381788Chart to determine the heating resistor for all types of enclosures and cubiclesDD381789Calculation dataP : power dissipated by the devices, connections and busbars (in Watts)P r : power of the heating resistor (in Watts)T m : maximum internal temperature in the device zone (in °C)T i : average internal temperature (in °C)T e : average external temperature (in °C)∆T m =T m – T e∆T =T i–T eS : total free surface area of the enclosure (expressed in m 2 )K : thermal-conduction coefficient of the material (W/m 2 °C)K = 5.5 W/m 2 °C for painted sheet metalD: ventilation throughput (in m 3 /h)Note: The dissipated power of each device is provided by the manufacturer.Add approximately 30% to account for the connections and the busbars.176


Schneider Electric Industries SAS89, boulevard Franklin RooseveltF - 92500 Rueil-Malmaison (France)Tel : +33 (0)1 41 29 85 00http://www.schneider-electric.comhttp://www.schneider-electric.coART 900001As standards, specifications and designs change from time to time, please ask for confirmationof the information given in this publication.This document has been printedon ecological paper.Designed: C.R.T. / AmegPhotos: Schneider Electric Industries SAS, M. Bougot, Headlines, 3D VisionPrinted: Imprimerie des Deux Ponts05-2004DESW015EN © 2004 - Schneider Electric - All rights reserved.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!