<strong>Technical</strong> <strong>Data</strong><strong>Lambda</strong>-<strong>Transmitter</strong> <strong>LT</strong> 1Extract from the TÜV Qualification TestTÜV- Qualification Test in accordance 13 th und 17 thBlm SchV502/0118/96/689724/01Tested measuring range at 0...21 vol. %O 2Availability 99,5%Maintenance rate4 weeksDetection limit 0,02 vol. % O 2Effect of the vapour contentLine voltage influenceAmbient temperatureEffect of temperature variationResponse time t 90-0,20 vol. % O 2 (-0,95% of the metering range limit value)No effect-20°C bis +50°CZero pointreference point20 sec.Drift in maintenance periodZero pointsensitivityRepeatability 330Linearity at measuring range0....21 vol. % O 2< 0,10 vol. % O 2≤ 0,20 vol. % O 2≤ 0,20 vol. % O 2< ±0,02 vol. % O 2< 0,10 vol. % O 2