Technical Data Lambda-Transmitter LT 1 - lamtec

Technical Data Lambda-Transmitter LT 1 - lamtec

Technical Data Lambda-Transmitter LT 1 - lamtec

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

System components<strong>Lambda</strong>-<strong>Transmitter</strong> <strong>LT</strong> 1Basic construction with integral pump and calibration device for under-roof installationCalibrating gas connectionPressure sensorMeasured gas1 Probe installation fitting (SEA)No. 6 55 R 0083...R 11832 <strong>Lambda</strong> Probe LS 1No. 6 50 R 0031...R 0039Measured-gasreturn with blindclosure plugPressure sensorCalibrating gasconnection3 Gas extraction device (MEV) with extraction filtere.g. 1000 mm long No. 6 55 R 0027matching protective tube No. 6 55 R 0620PG screw connections (cable glands)4 Mating flangeNo. 6 55 R 0183 / R 01855 Insulation for LS 1 7 Flange seal, BAS greenNo. 6 57 P 0100 No. 6 50 P 42096 <strong>Lambda</strong> <strong>Transmitter</strong> <strong>LT</strong> 1 with integral measured 8 Indictor and control unit (option)gas pump and automatic calibration device (option) No. 6 57 R 0800No. 6 57 R 0020...R 0025 and 6 57 R 0800If the distance between the <strong>Lambda</strong> Probe LS 1 and the <strong>Lambda</strong> <strong>Transmitter</strong> <strong>LT</strong> 1> 10 m, it is recommended to provide a probe connection box (SAK) with themeasured-gas pump and, if necessary, with the automatic calibration device (option),close to the probe.For open-air installation, a transmitter protection box is also necessary for weatherprotection.Basic construction of <strong>LT</strong> 1 / LS 1 with external pump and calibration deviceMax. 400 °CIf the temperature of the measured gasis higher, the SEA must be set back further.Flue gas ductPressure sensor1 <strong>Lambda</strong> Probe LS 1No. 6 50 R 0031...R 00392 Gas extraction device (MEV) withextraction filter e.g. 1000 mm longNo. 6 55 R 0027matching protective tubeNo. 6 55 R 06203 Probe installation fitting (SEA)No. 6 55 R 0083 / R 1183Measured gasMeasured-gasreturnCalibrating gasconnectionPressure sensor connectionCalibrating gas supply<strong>Transmitter</strong> protection box,essential for open-air installation4 Insulation for LS 1 and SEANo. 6 57 P 01005 Probe connection box (SAK)No. 6 57 R 00136 <strong>Lambda</strong> <strong>Transmitter</strong> <strong>LT</strong> 1,external measured-gas pumpNo. 6 57 R 0021 / R 00267 Indicator and control unit (option)No. 6 57 R 0830Probe connection boxwith measured-gas pump,calibration deviceLAMBDA-TRANSMITTER <strong>LT</strong> 1Pump, externalCondensatecollector8 <strong>Transmitter</strong> protection box (option)No. 6 55 R 00879 Mating flangeNo. 6 55 R 0180 / R 0187Temperature of measured gas:> water or acid dew point, up to 700 °C, up to 1400°C (optional)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!