Technical data<strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>Facts and figures: the <strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>Model<strong>F800</strong>ApplicationPrivate swimming pools in m 2 50Maximum size of water surfacemin. 20 °C / 40 % rel. hum. (h=35 kJ / kg)Limits for ambient room conditionsmax. 36 °C / 60 % rel. hum. (h=94 kJ / kg)Pool water condenser (PWC) 1) with PWC without PWCDehumidification performance during operationin recirculated-air mode 2) kg/h 3.9 3.4Heating capacity 2) (excess energy) kW 4.4 (2.9 to water) 4.6Air flow rate for speed 1 / speed 2 m 3 /h 400 / 800Maximum external pressure loss Pa 20Power consumption (fan motor) kW /A 0.16 / 0.72Compressor power consumption 2) kW /A 1.55 / 7.7 1.73 / 8.0Maximum starting current A 47Wattage of equipment connected load /max. operating current kW /A 2.8 / 13.7Supplementary PWW heating registerHeating output for PWW 80/60°C 3) kW 3.1 / 4.0Pressure loss on the water side kPa 1.7Operating voltage V/phase/Hz 230/1/50Control voltage (safety extra-low voltage, SELV) V (DC) 24Degree of protection provided by enclosureIP.5Dimensions (L x H x D) mm 1660/800/290Weight kg approx. 1221)Volume flow of the pool water condenser = max 0.7 m 3 /h;water resistance of the pool water condenser = 8.0 kPaSelection of units:2)Pool water temperature + 28°C;condition of room air = 30°C and 60% relative humidity(not to be included in calculations for heat requirements).3)Return-air entry temperature = + 30°C, and fan speed I/IIBasic unit 1 (F8SG):Basic unit 2 (F8BG):Basic unit 3 (F8PG):Basic unit 4 (F8KG):Basic unit, with white enclosure,for installation in the swimming pool roomSame as basic unit 1, but with additionalpool water condenserSame as basic unit 1, but with additionalPWW supplementary heating registerSame as basic unit 1, but with pool watercondenser and PWW supplementaryheating registerAlso availablewithout enclosure:for example, for installation behind walls.VK_2272412GB .Version of 12/2005 . We reserve the right to make modifications without prior notice.2


Technical data<strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>6481 7 236251) Installation opening2) Outdoor-air fitting (accessory)3) Electric terminals4) R 1/2"i (internal threads) connection forpool water condenser (accessory)5) R 1/2"a (external threads) condensed-water drain6) Output louver7) Intake louver8) Output louver to front(e.g., for recess installation)9) R 1/2"i (internal thread) heatingwaterconnection (supply flow)(accessory)10) R 1/2"i (internal thread) heatingwaterconnection (return flow)(accessory)10928Outside-airconnection;accessory:type F8ZAA(diam. =150 mm)As seen fromPool roominstallationroom85012 111700 12~450 Approx. dimensionsin mm121314Installation room1111) Adapter for exhaust-air connection,for behind-wall installation(accessory, type F8ZAD2)12) Swimming pool air intake connection(e.g., air duct);connection diameter = 180 mm13) Supply air duct (provided bypool owner/operator)14) Duct connection unit, with sailclothconnection (accessory, type F8ZST)VK_2272412GB . Version of 12/2005 . We reserve the right to make modifications without prior notice.3


Technical data<strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>Facts and figures: the <strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>Equipment descriptionF8SG Basic unit, with white enclosure, for installation in the swimmingpool room; dehumidification in recirculated-air mode; refrigerationcycle with fully hermetic scroll <strong>com</strong>pressor; <strong>com</strong>pletely piped andfilled with environmentally benign refrigerant; with <strong>com</strong>pleteinternal electric wiring; with electronic system with all functions,including the safety chain, for protection of installed <strong>com</strong>ponentsand for provision of safety extra low voltage (SELV) for the humiditycontroller (see accessory F8ZRG); all materials with corrosionresistantproperties, for application with the atmosphere and waterquality generally prevailing in swimming pool rooms.F8S Same as F8SG, but without enclosure: e.g., for installation behind walls.F8BG The basic unit, but with additional pool water condenser for deliveryof part of the recovered heat to the pool water, for even greaterincrease in cost effectiveness.F8B Same as F8BG, but without enclosure: e.g., for installation behind walls.F8PG The basic unit, but with additional PWW supplementary heatingregister for enhancement of heating output; absolutely necessaryfor operation of dehumidifiers with outside-air fraction.F8P Same as F8PG, but without enclosure: e.g., for installation behind walls.F8KG The basic unit, but with pool water condenser and PWW supplementaryheating register.F8K Same as F8KG, but without enclosure: e.g., for installation behind walls.4Accessories (provided separately)F8ZRG Humidity controller, as remote controller; with operation lamp,malfunction signal lamp, operation switch, and setpoint adjuster;operation with safety extra low voltage (SELV) from the basic unit;open- and closed-loop control for a maximum of two <strong>F800</strong> unitsoperated in parallel in one facility (see accessory F8ZRK).F8ZBP Self-priming swimming pool water pump; corrosion-resistant;230 V AC; output 700 l/h; 20 kPA; power consumption = 100 W(must be operated together with F8B/BG or F8K/KG).F8ZBT Immersion pool water thermostat; with V4A stainless-steelimmersion sleeve; for limitation of pool water temperature(must be operated together with F8B/BG or F8K/KG).F8ZST Duct connection unit, with sailcloth connection pieces, for supply air;for installation behind walls.F8ZAA Outside-air connection fitting; diameter 150 mm; for operation of thebasic unit with outside-air fractions (may be operated only togetherwith F8P/PG or F8K/KG and exhaust-air fan).VK_2272412GB . Version of 12/2005 . We reserve the right to make modifications without prior notice.


Technical data<strong>GEA</strong> <strong>Fricostar</strong> <strong>F800</strong>Accessories (provided separately)F8ZHAF8ZAVF8ZRKRear wall of equipment unit, enamel-painted in the colour of theenclosure (effective for a visible rear wall; e.g., for installation infront of a window).<strong>GEA</strong> wall flush-mounted exhaust-air fan; 230 V AC; 3-speed; madeof plastic; automatic closure flap; wall sleeve 170 mm long; air-flowvolume = 130 / 235 / 325 m 3 /h; 2-speed control and voltage sourcedirectly possible from basic unit.Additional switchbox for parallel switching of two <strong>F800</strong> units, withits own safety extra low voltage (SELV) supply; the <strong>F800</strong> unitsconnected in parallel are operated with a <strong>com</strong>mon humiditycontroller (F8ZRG).Outside-airconnection;accessory:type F8ZAA(diam. =150 mm)As seen frominstallation room8501700F8ZAD2 Adapter for exhaust-air /supply-air connection for behind-wallinstallation, for connection to the basic unit; air flows from theswimming pool to the adapter via air ducts or hoses with roundconnection fittings.F8ZSLSpecial enamel paint in RAL colours.Pool roomInstallation roomF8ZKLSpecial corrosion protection; enamel-painted refrigeration cycle.Approx. dimensions in mm~450Typical <strong>F800</strong> configuration,featuring poolwater condenser.Note:System performance withouta pool water condenser isreduced by approx. 15 %.Maximum pool surfaceaccording to the examplebelow = 38 m 2 x 0.85 = 32 m 2 .Relative humidity in % Water temperature in °C34Example:Pool room temperature 30°CPool room humidity 60% RHWater temperature 28°CWater surface area 38 m 2(see example curves)Air temperature in °C Pool surface in m 2VK_2272412GB . Version of 12/2005 . We reserve the right to make modifications without prior notice.5


VK_2272412GB . Version of 12/2005 . We reserve the right to make modifications without prior notice . Copyright <strong>GEA</strong> Air Treatment.