28.11.2012 Views

EC-TYPE EXAMINATION CERTIFICA TE HSE

EC-TYPE EXAMINATION CERTIFICA TE HSE

EC-TYPE EXAMINATION CERTIFICA TE HSE

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2<br />

<strong>EC</strong>- <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICA</strong> <strong>TE</strong><br />

Equipment or Proteetive System Intended lor use<br />

in Potentially Explosive Atmospheres<br />

Directive 94/9/<strong>EC</strong><br />

3 <strong>EC</strong>- Type Examination Certificate Number BASOIA <strong>TE</strong>X2210X<br />

4 Equipment or Protcctive System: <strong>TYPE</strong> TB RANGE OF JUNCTlON BOXES<br />

5 Certificate held by: WEIDMULLER IN<strong>TE</strong>RFACE GmbH & CO<br />

6 Address: Paderboner Strasse 175, 32760 Detmold, Germany<br />

7 This equipment or protective system and any acceptable variation thereto is spccified in the schedule<br />

to this certificate and the documents therein relerred to.<br />

8 The Electrical Equipment Certification Serviee, notified body number 600 in accordance with<br />

Article 9 01 the Council Directive 94/9/<strong>EC</strong> o[ 23 March 1994, certifies that this equipmenl or<br />

protective system has been [ound to comply with the Essential Hcalth and Safety Requirements<br />

rc1ating to the design and construetion 01 equipment and protective systems intended lor use in<br />

potentially explosive atmospheres given in Annex 1I to the Directive.<br />

The examination and test results are recorded in confidential Report N"<br />

OI(C)0515 dated 6 September 2001<br />

9 Compliance with the Essential Health and Safety Requirements has been assured by compliance with:<br />

EN 50014: 1997 + Amds I & 2 EN 50019: 2000 EN 50281-1-1: 1998<br />

except in respect olthose requirements listed at item 18 ofthe Schedule.<br />

10 If the sign "X" is placed after the certificate number, it indicates that the equipment or protective<br />

system is subject to special conditions for safe use spccified in the schedule to this certificate.<br />

11 This <strong>EC</strong>-<strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICA</strong><strong>TE</strong> relates only to the design and construction 01 the<br />

specified equipment or protective system. If applicable, further rcquirements 01 this Directive apply<br />

to the manulacture and supply of this equipment or protective system.<br />

12 The rnarking of the equipment or protective system shall include the lollowing:-<br />

® " 2 GD T85°C EExe 11T6<br />

This certificate rnay only be reproduced in its entirety and without any change, schedule included.<br />

File No: E<strong>EC</strong>S 4415/03/002<br />

This certificate is granted suhjcct 10 thc general conditions of the Electrical<br />

Equipmcnt C.cr1ific~tion S~rvicc .. It doe~ not nccessarily indicate that the apparatus<br />

may bc uscd In partlcular mdustncs or clrcllmslances.<br />

~~<br />

<strong>HSE</strong><br />

,,~ ••I,h r. S"lcly<br />

E.eo:;ulln"<br />

Electrical Equipment Ccrtification Service<br />

I1calth and ~afct)· Encutive<br />

lIarpur nm, Huxton. I>crb,yshlre. SK17 9JN. Unitcd Kingdom<br />

Tel: +44(0)1298 2HOOOFu: +44(0)1298 28244<br />

internet: www.bascefa.come-maU:ba~l.l.ra.lö1fo.eecs@hsl.l!:ov.uk<br />

CERT\A<strong>TE</strong>X\EQUlP\CATl.2\P*, Issuc I, Dated September 1998<br />

I M CLEARE<br />

D1R<strong>EC</strong>TOR<br />

4 October 200 I<br />

Page 1/4


J<br />

J<br />

J<br />

13<br />

14<br />

15<br />

Schcdulc<br />

<strong>EC</strong>-TVPE <strong>EXAMINATION</strong> <strong>CERTIFICA</strong><strong>TE</strong> N' BASOIA<strong>TE</strong>X221OX<br />

Dcscription or Equipmcnt or Protcctive System<br />

The Type TB Range or Junction Boxes comprising the component certified range or empty<br />

enelosures covered by <strong>EC</strong>-Type Examination Certificate No BASOIA<strong>TE</strong>X2208U, coded ® 1I2 GD<br />

EEx e 1I fitted with terminals having their own <strong>EC</strong>-Type Examination Component Certificate<br />

Numbers and list on Document No: TSG-A<strong>TE</strong>X, issue I, dated Ist May, 2001.<br />

The terminals must be used within their relevant voltage, CUITentand temperature limitations whilst<br />

complying with all their relevant Schedule of Limitations and creepage and elearance distances<br />

required by EN 50019.<br />

In order to maintain the temperature elass called up on the label the maximum power dissipated<br />

within the box must not exceed that shown in the table for the individual enclosures.<br />

Earthing facilities and cable entries are described as part of the empty enelosure certificate (No<br />

BASOIA<strong>TE</strong>X2208U).<br />

VARIATION 0.1<br />

Increased ambient temperature of 60°C with a consequential reduction in the maximum power<br />

dissipated as shown in the table.<br />

VARIATION 0.2<br />

Alternative tcmperaturc dass T5 to permit an incrcase in thc maximum power dissipatcd as shown<br />

in the table.<br />

VARIATION 0.3<br />

Inclusion of terminals for intrinsically safe (I.S.) circuits within the enelosure. With this<br />

arrangement the coding changes to:-<br />

VARIATION 0.4<br />

EEx e rial 1I<br />

Terminals for I.S. circuits only contained within the enelosure. With this arrangement the coding<br />

changes to:-<br />

EEx ia 1I<br />

Page 2/4


•<br />

~. ~ ~<br />

13 -Schcdulc<br />

14 <strong>EC</strong>-<strong>TYPE</strong> EXAMINATlON CERTlFICA<strong>TE</strong> N" BASOIA<strong>TE</strong>X2210X<br />

TABLE OF MAXIMUM POWER RATINGS<br />

ENCLOSURE <strong>TYPE</strong><br />

MAXIMUM DISSIPA<strong>TE</strong>D POWER (W)<br />

T6 AT T.mb= 40°C T6 AT T.mb= 60°C T5 AT T.mb= 40°C<br />

TB 10 7.7 3.8 9.6<br />

TBll, TBIID 16.9 8.4 2Ll<br />

TB12, TBI2B, TBI2D 27.4 13.7 34.2<br />

TBl2A 34.1 17.0 42.6<br />

TBI2C 25.4 12.7 31.7<br />

TBI3, TB13B, TBI3D 52.6 26.3 65.7<br />

TBI4, TBl4D, TB 14/3 78.5 39.2 98.1<br />

CALCULA TION OF MAXIMUM NUMBER OF <strong>TE</strong>RMINALS PER BOX<br />

The maximum number of terminals whieh may be fitted into eaeh enclosure is ealeulated using the<br />

following formula:<br />

Power = I' x N(R; + R;) Watts<br />

wherc:<br />

1 = aetual eurrent through the eonduetor up to the maximum eertified eurrent of the terminal<br />

(amps)<br />

N = number oftcrminals<br />

R, = terminal resistanee (Ohms @ 20°C) •<br />

R; = resistanee of one eonduetor (Ohms @ 20°C) when using a maximum diagonal eable length for ~<br />

thc cnclosurc in question.<br />

16 Rcporl No,<br />

01(C)0515<br />

17 Special Conditions For Safe Usc<br />

1. Not more than one single or multiple strand wiring lead shall be eonnccted into either side of<br />

any terminal.<br />

2. All terminal serews, used and unused, shall be lightencd down.<br />

3. Any cross eonneeted terminal assembly fitted with a jumper bar shall be mounted and used<br />

subjeet to the limitations given in the eertifieation documents for that terminal.<br />

4. Leads eonneeted to the terminals shall bc insulated for the appropriate voltage and the<br />

insulation shall cxtcnd to within Imm ofllte metal orthe terminal throat.<br />

Page 3/4<br />

l~


~<br />

13<br />

14<br />

-Sehedule<br />

<strong>EC</strong>-<strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICA</strong><strong>TE</strong> N' BASOIA<strong>TE</strong>X22IOX<br />

5. To maintain the temperature dass and to limit the maximum temperature of PVC conductor<br />

insulation to 80°C, the wiring conductors of power circuits should not bc loomed in such a ~<br />

manner as to significantly increase the temperature of any individual conductor. In the<br />

absence of other information, a satisfactory method of achicving this object would be 10 ensure ~<br />

that no conductor is containcd \vithin a wiring 100m comprising a greatcr number of<br />

conductors than the cable or conduit from which the conducter originales.<br />

18 Essential lIealth and Safety Requirements<br />

None that are not covered by assessmenl against EN 50014: 1997, EN 50019: 2000 and EN 50281-1-1: 1998.<br />

19 DOCUMENTS<br />

Number<br />

701542<br />

723535<br />

723536<br />

723537<br />

BA SOIA<strong>TE</strong>X2207X<br />

Issue<br />

o<br />

o<br />

o<br />

o<br />

Date<br />

27.4.0 I<br />

18.4.01<br />

18.4.01<br />

26.4.01<br />

22.8.01<br />

Dcscription<br />

Label Engraving Information<br />

Label (e)<br />

Label (elia])<br />

Label (ia)<br />

Type TBX Range of Junction Boxes - Original Certificate<br />

This certificate may only bc reproduced in its entirety and without any change, schedule induded.<br />

BASEEFA List Kcywords<br />

2JUNCBOX<br />

. -<br />

-. ~.<br />

Page 4/4<br />

J


2<br />

3<br />

4<br />

5<br />

6<br />

Certificate Number<br />

BAS01A<strong>TE</strong>X2210Xl1<br />

Issued 27 November 2002<br />

Page 1 of 2<br />

SUPPLEMENTARY <strong>EC</strong> - <strong>TYPE</strong> <strong>EXAMINATION</strong> <strong>CERTIFICA</strong><strong>TE</strong><br />

Equipmcllt or Protecti\'c System Intended ror use in Potentially Explosive Atmospheres<br />

Oirective 94/9/E:C<br />

Supplementary <strong>EC</strong> - Type Examination Certificate<br />

Number :<br />

Equipment cr protective system:<br />

Certificate is held by :<br />

Address :<br />

ßASO 1A<strong>TE</strong>:X22IOX/I<br />

<strong>TYPE</strong> TB RANGE: OF JUNCTlON BOXE:S<br />

WE:IDMULLER IN<strong>TE</strong>:RFACE: GmhH & CO<br />

Paderborner Straße 175, 0-32760, Oetmold, Germany<br />

7 This supplementary certificate, issued by ßaseefa (2001) LId., Notilied ßody Number 1180, extends <strong>EC</strong> - Type<br />

Examination Certificate No. ßASO IA<strong>TE</strong>X2210X to apply to equipment or protective systems designed and<br />

constructed in accordance with the specification set out in the Schedule ofthe said certificate but having any<br />

variations specified in the Schedule attached to this certificate and the documcnts therein referred to.<br />

This Supplementary Certificate shall be held with the original Certilicate<br />

The Electrical Equipment Certification Service, Notified ßody Number 0600, retains responsibility for its original<br />

documentation. Baseela (200 I) LId. is responsible only for the additional work relating to this supplementary<br />

certificate and any other supplementary certificate that it has issued.<br />

This certificate may only be reproduced in its entirety, without any change, Schedule inc1uded.<br />

ßaseefa (200 I) Ltd. Customer Reference No. 4221<br />

This certificatc is granted subjcct to thc general terms and conditions of<br />

Basccfa (200 I) LId. It docs not ncccssarily indicale that thc cquipmcnt<br />

may bc uscd in particular industries or circumstanccs<br />

Baseefa (2001) Ud.<br />

Health and Safety Laboratory Site, Harpur Hili,<br />

Buxton, Derbyshire SK17 9JN<br />

Telephone +44 (0) 129828255 Fax +44 (0) 129828216<br />

e-mail info(ä)baseefa2001.biz web site Wo/IfW.baseefa2001.biz<br />

Registered in England No. 4305578 at 13 Dovedale Crescent, Buxton,<br />

Derbyshire, SK17 9BJ<br />

Project File No. 02/0455<br />

R S SINCLAIR<br />

DIR<strong>EC</strong>TOR<br />

On behalf of<br />

Baseefa (2001) LId.


Certificate Number<br />

BAS01A<strong>TE</strong>X2210X/1<br />

Schedule<br />

Description of the variation to the Equipment or I}rotective System<br />

Variation t.l<br />

Ta permit a change of marking on the box to inc1ude:<br />

Report No.<br />

None<br />

Special Conditiolls for Safe Use<br />

As per original certificate<br />

Essentiaillealth alld Safety Requirements<br />

As per original certificate<br />

Drawings and Documents<br />

Number<br />

723535<br />

723536<br />

723537<br />

701542<br />

BASOI A<strong>TE</strong>X2207X/I<br />

Issue Date<br />

8/1 1/02<br />

8/1 1/02<br />

8/1 ]/02<br />

8/11/02<br />

27/1 1/02<br />

® 112G EEx e 11'1'6 or '1'5<br />

® 112G EEx elialll '1'6 or '1'5<br />

® IIIG EEx ia 11'1'6 or '1'5<br />

Description<br />

Label (el<br />

Label (e[ia])<br />

Label (ial<br />

Label engraving information<br />

Issued 27 November 2002<br />

Page 2 of 2<br />

Type TBX Range of Junction Boxes Certificate

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!