12.07.2015 Views

Breathing life into your environment - Ferrob

Breathing life into your environment - Ferrob

Breathing life into your environment - Ferrob

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Breathing</strong> <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>CODE DESCRIPTION CODE DESCRIPTIONUAX *UAX 150UAX 150 SUAX 150 HTSUAX 150 TRSUAX 100UAX 100 SUAX 100 TUAX 100 HTSUAX 100 PIRUAX 100 TRSUAX 100 LV SUAX 100 LV TUAX 100 LV HTSUAX 100 LV PIRUAX 100 LV TRSPCH 100 TRSUAX-ES *UAX ES 150UAX ES 150 SUAX ES 150 HTSUAX ES 100UAX ES 100 SUAX ES 100 TUAX ES 100 HTSUAX ES 100 LVUAX ES 100 LVSUAX ES 100 LVTUAX ES 100 LVHTS150mm fan only for remote switching150mm fan with pull switch150mm fan with humidity sensor/timer and pull switch150mm fan, continuous running with manual boost pull switch100mm fan only for remote switching100mm fan with pull switch100mm fan with timer100mm fan with humidity sensor/timer and pull switch100mm fan with passive infra-red detector100mm fan, continuous running with manual boost pull switch100mm low voltage fan with pull switch100mm low voltage fan with timer100mm low voltage with humidity and timer/pull switch100mm low voltage with Passive Infra-red movement detector100mm low voltage continuous running with manual boost pullswitchDMEV 100mm continuous running with pullcord boost.(Switch selection for kitchen and bathroom)150mm fan only for remote switching150mm fan with pull switch150mm fan with humidity sensor/timer and pull switch100mm fan only for remote switching100mm fan with pull switch100mm fan with timer100mm fan with humidity sensor/timer and pull switch100mm low voltage fan only for remote switching100mm low voltage fan with pull switch100mm low voltage fan with timer100mm low voltage fan with humidity sensor/ timer and pullswitchSENSORTRONIC DIGITAL *D 1000D 400 HSD 400 HTD 400 LV HSD 400 LV HTSENSORTRONIC LOGIC *L 1000L 400 HSL 400 HTL 400 LV HSL 400 LV HTCENTRIFUGALCF 200CF 200 SCF 200 HTSCF 200 TRSCF 100CF 100 SCF 100 TCF 100 HTSCF 100 TRSCF 100 LV SCF 100 LV TCF 100 LV TRSCF 100 LV HTSSensortronic 1000 digitalSensortronic 400 digital humidity and pull switchSensortronic 400 digital humidity and timerSensortronic 400 digital low voltage humidity and pull switchSensortronic 400 digital low voltage humidity and timerSensortronic 1000 logicSensortronic 400 logic humidity and pull switchSensortronic 400 logic humidity and timerSensortronic 400 logic low voltage humidity and pull switchSensortronic 400 logic low voltage humidity and timerCentrifugal 100mm fan for remote switchingCentrifugal 100mm fan with pull switchCentrifugal 100mm fan with humidity, timer and pull switchCentrifugal 100mm fan continuous running and manual boostCentrifugal 100mm fan for remote switchingCentrifugal 100mm fan with pull switchCentrifugal 100mm fan with timer onlyCentrifugal 100mm fan with humidity, timer and pull switchCentrifugal 100mm fan continuous running and manual boostCentrifugal 100mm low voltage fan with pull switchCentrifugal 100mm low voltage fan with timer onlyCentrifugal 100mm low voltage fan continuous running andmanual boostCentrifugal 100mm low voltage fan with humidity, timer andpull switchUCF – CENTRIFUGALUCF 100 TUCF 100 HTSUCF 100 LV SUCF 100 LV TUCF 100 LV HTSUCF 100 LV TRSSLIMLINE *SL 100SL 100 SSL 100 TSL 100 HTSSL 100 LV SSL 100 LV TSL 100 LV HTSSL 150SL 150 SSL 150 TSL 150 HTSSENSORTRONIC 400 & 1000 *Centrifugal 100mm fan with timerCentrifugal 100mm fan with humidity sensor/ timer and pullswitchCentrifugal 100mm low voltage fan with pull switchCentrifugal 100mm low voltage fan with timerCentrifugal 100mm low voltage fan with humidity sensor/timerand pull switchCentrifugal 100mm low voltage fan continuous running withmanual boost pull switch100mm fan only for remote switching100mm fan with pull switch100mm fan with timer100mm fan with humidity sensor and timer100mm low voltage fan with pull switch100mm low voltage fan with timer100mm low voltage with humidity and timer150mm fan only for remote switching150mm fan with pull switch150mm fan with timer150mm fan with humidity sensor and pull switchS 1000 Sensortronic 1000S 1000 TRSSensortronic 1000 continuous running with pull switch andhumidity boostS 400 HTSensortronic 400 humidity and timerS 400 HSSensortronic 400 humidity and pull switchSENSORTRONIC MICRO *M 1000M 400 HSM 400 HTM 400 LV HSM 400 LV HTM 1500Sensortronic 1000 microSensortronic 400 micro humidity and pull switchSensortronic 400 micro humidity and timerSensortronic 400 micro low voltage humidity and pull switchSensortronic 400 micro low voltage humidity and timerHand held monitoring unit for micro ranges of fansSENSORTRONIC DIGITAL LOW WATT *D1000 LWD400 LW HSD400 LW HTD400 KLWTRHSD400 BLWTRHTSensortronic 1000 Digital Low WattSensotronic 400 Digital low watt humidity & pull switch boostSensortronic 400 Digital low watt humidity & timer boostSensotronic 400 Digital low watt continuous running withhumidity & pull switch boostSensortronic 400 Digital low watt continuous running withhumidity & timer boostARIDAIR (PIV)M 2000Sensortronic 2000 Aridair micro with 1 sensorS 2000 NISensortronic 2000 Aridair - continuously on slow speed withan automatic summer / winter cut-out.S 2000 LWSensortronic 2000 Aridair with 2-speed manual control - lowwattageS 2000 LWH Sensortronic 2000 Aridair with 2-speed manual control andheater - low wattageM 2007Sensortronic 2000 Aridair micro sensorS 3000 LW LW Sensortronic 3000 Aridair with 2-speed manual control -low wattageS 3000 LWH Sensortronic 3000 Aridair with 2-speed manual control andheater - low wattageDK1WHOLE HOUSE (MEV)Ducting kits for S 3000 – flat duct per metreFor Kitchen and BathroomCD 125 MRV Multi-room extract system complete with kitCD 125 MRVH Multi-room extract system with humidity boost complete withkitRB 1007Remote relay box for multiple remote activationHEAT RECOVERY – SINGLE ROOM (MVHR)HR 100 HTS GHR 100 LV HTS GHR 100 SGHR 100 LVSGHRIC 100HRCEHeat recovery unit - 100mm continuous trickle with humiditysensor/timer and integral pull switch boostHeat recovery unit - 100mm low voltage continuous trickle,boost activated by either humidity sensor/timer or remote pullswitchHeat recovery unit – 100mm continuous trickle with balancedintake/extractHeat recovery unit – 100mm low voltage continuous tricklewith balanced intake/extractHeat recovery internal cowlCeiling kit for all Heat recovery models(Complete with Wall/Window kits)HEAT RECOVERY – WHOLE HOUSE (MVHR)HRWH* Axial FansWhole House heat recovery – continuous trickle with built-inboost from up to 4 switched-live feeds(Kit available separately)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.uk2011


<strong>Breathing</strong> <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>CODE DESCRIPTION CODE DESCRIPTIONINLINE DUCT UNITS1004 100mm 2 speed in-line fan1004 T 100mm in-line fan with timer1005 125mm 2 speed in-line fan1005 T 125mm in-line fan with timer1006 T 150mm in-line fan with timerD 1004100mm in-line fan system with D 1007 controllerD 1005125mm in-line fan system with D 1007 controllerL 1004100mm in-line fan system with L 1007 controllerL 1005125mm in-line fan system with L 1007 controllerM 1004100mm in-line fan system with M 1007 controllerM 1005125mm in-line fan system with M 1007 controllerUAX 1004100mm in-line fan with UAX 1007 controllerUAX 1005125mm in-line fan with UAX 1007 controllerCOOKER HOODCK 100(With 3m flexible ducting and external fixed or gravity grille)Cooker hood - 3 speed with lightACCESSORIES – WALL/WINDOW COWLSCG 100CG 150CGW 100CGW 150IC100IC150Cowled wall grille 100 mmCowled wall grille 150 mmCowled window grill 100 mmCowled window grille 150 mmInternal cowl 100 mmInternal cowl 150 mmACCESSORIES – FLAT CHANNEL (110mm x 54mm WHITE)12-01 Flat channel 1 metre lengths12-02 Flat channel clip12-03 Flat channel connector12-05 Adapter flat to round angled12-06 Flat horizontal 90 o bend12-07 Flat vertical 90 o bend12-08 Adapter (long) flat to round straight12-09 Adapter (short) flat to round straight12-20 Flat duct wall plateLIGHT COMMERCIALLC 230LC 230 RVLC 300LC 300 RVREMOTE CONTROLLERSLight commercial 230 fan - auto shutters - single speedLight commercial 230 fan - auto shutters with 3 speedreversible controllerLight commercial 300 fan - auto shutters - single speedLight commercial300 fan - auto shutters with 3 speedreversible controller(Complete with either Wall/Window kits)1414 Speed controller for remote useD 1007Sensortronic 1007 digital remote controller with sensorL 1007Sensortronic 1007 logic remote controller with sensorM 1007Sensortronic 1007 micro remote controller with sensorUAX 1007Remote humidity controllerUAX1007LV Remote humidity controller – Low VoltageACCESSORIES – FLAT CHANNEL (204mm x 60mm WHITE)204-01 Flat channel 2 metre lengths204-02 Flat channel clip204-03 Flat channel connector204-04 Elbow bend with 100mm spigot204-05 Horizontal 90 o bend204-06 Vertical 90 o bend204-07 Horizontal equal T-piece204-08 Round to rectangular adaptor 100mm204-09 Flat channel wall plate204-10 Elbow bend with rotating offset spigot 100mm204-11 Flat channel connector with damper204-12 Adjustable horizontal bendACCESSORIES – ROUND PIPE (100 mm Dia white)12-10a Round pipe 1 metre lengths12-10b Round pipe 2 metre lengths12-11 Round pipe connector 100mm12-12 Round pipe 90 o bend12-18 Round equal T piecePASSIVE VENTILATORCV 100Cosivent 100mmPV 100Passive vent 100mmPV 150Passive vent 150mmTDR 100100mm tumble dryer vent kitACCESSORIES – WALL/WINDOW GRILLESFG 100Fixed external grille 100mmFG 150Fixed external grille 150mmGG 100Gravity external grille 100mmGG 150Gravity external grille 150mmWG 100Window grille 100mmWG 150Window grille 150mmSHOWER FANSF 100SF 100 T100mm shower fan with 3 metres ducting and 2 grilles100mm shower fan with timer, 3 metres ducting and 2 grillesGENERAL ACCESSORIESBS 100Back-draught shutters 100mmBS 150Back-draught shutters 150mmCT 100Condensation trap 100mmCT 150Condensation trap 150mmFD 100Flexible ducting 100mm (prices per metre)FD 125Flexible ducting 125mm (prices per metre)FD 150Flexible ducting 150mm (prices per metre)FD 100 INInsulated flexible ducting 100mm (prices per 10 metre)FD 125 INInsulated flexible ducting 125mm (prices per 10 metre)FD 150 INInsulated flexible ducting 150mm (prices per 10 metre)FDA 100Fire damper 100mmFDA 150Fire damper 150mmRED 100/125 Reducer 100mm – 125mmRED 125/150 Reducer 125mm – 150mmWS 100Wall Sleeve 100mm (275mm length)WS 150Wall Sleeve 150mm (275mm length)WP 100/150Wall Plate<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.uk2011


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>UAX100 Range: 230v and 12vExtract rate90m³/hr, 27 litresper secondFans can be wall,ceiling or windowmountedBritish madeThe UAX100 range of 100mm (4") bathroom and toilet fans comprises quiet, efficient,axial flow fans for wall, ceiling or window mounting.Designed for easy installation, attractively styled in high gloss ABS thermoplastics formodern appearance and ease of cleaning and incorporating the latest technology anddesign.The UAX100 series is ideally suited for domestic applications including bathrooms,toilets and shower areas.The range also includes 12v Low Voltage models for use when required.Designed to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to complywith HD280/BS3456Part 102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.UAX100UAX100SUAX100TUAX100PIRUAX100HTSUAX100TRSUAX100TRSHTypeStandard model - for remote switching.As above supplied with Pullcord switch.Timer model - with integral over-run timer (15 mins).Passive Infra Red – Movement detector with adjustable over run timer (3 to 30 Min)Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and Pullcord switch.Continuously running trickle speed with Pullcord boost switch.Continuously running trickle speed with Pullcord boost switch and hour run meter.Low Voltage 12v modelsCatalogue No.UAX100LVSTypewith Pullcord switch.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.ukNov06


UAX100LVTUAX100LVPIRUAX100LVTRSUAX100LVTRSHUAX100LVHTSTimer model incorporating integral over-run timer (15 mins).Passive Infra Red – Movement detector with adjustable over run timer (3 to 30 Min)Continuously running trickle speed with Pullcord boost switch.Continuously running trickle speed with Pullcord boost switch and Hour-Run meter to monitorlength of time power is turned on.Humidity Control – the fan will run when the humidity rises over the pre set 65% RH. Completewith integral timer (15min) and Pullcord switchConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish220-230V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mm inall poles, must be used with a 3 amp fuse fitted and mounted a minimum of 1.75 metresfrom the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong> andprotected by a thermal fuse.Two year no quibble guarantee.Both 230v and 12v ranges are designed to be wall, window or ceiling mounted. Kitsavailable on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m 100mm flexible ducting and an external fixed grille (colours tosuit).Installation through a wall or ceiling requires a 107mm hole, through a window a 126mmhole.UAX100 / UA100LV - extract rate of 90m³/hr, 27 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating: - IPx4Unit Dimensions & Cut-outsF166mmG166mmH100mmJ42mmK42mmWall Hole 107mmCeiling Hole 107mmWindow Hole 126mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageLowVoltageNoise levelWarrantyFanSpeedColourSelf-cleaningsensorMaxpressureDigitaldisplaySpeedoptionsDownloadfacility90m 3 /h27ltrs/sec220/230 20 Yes 40db 2 year RTB 2400 White No 50 p.a. No No NoNOTES:* Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>UAX ES1 5 0 Range: 2 3 0 vThe UAX ES150 range of 150mm (6")kitchen fans comprises quiet, efficient,axial flow fans for wall, ceiling, or windowmounting.Designed for easy installation, attractivelystyled in high gloss ABS thermoplastics formodern appearance and ease of cleaningand incorporating the latest technologyand design.The units have silently operating electricshutters controlled by a well proven thermo-electric activator. These shuttersare designed to eliminate back-draughtThe UAX ES 150 series is ideally suited for domestic kitchen applications.Extract rate 295m³/hr, 83litres per secondFans can be wall, ceilingor window mountedBritish madeDesigned to exceed the2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.UAX ES 150UAX ES 150 SUAX ES 150 HTSTypeStandard model - for remote switching.As above supplied with pull switch.Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and pull switch.ConstructionElectricalMotorGuaranteeThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 26 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mmin all poles, must be used with a 3 amp fuse fitted. The fan should be mounted aminimum of 1.75 metres from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator, cooker.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


InstallationPerformanceAdditional DataDesigned to be wall, window or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and an external fixed gravity grille(white, terracotta, stone, grey or brown)Window kits comprise an external white fixed grille and internal fixing plate. Doubleglazedwindow kit supplied as standard. For single-glazed windows, request special kitwhen ordering.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille (colours tosuit)Installation through a wall or ceiling requires a 162mm hole, through a window a175mm hole.UAX-ES150 - extract rate of 295m³/hr, 83 litres per second.Maximum pressure: 80 p.a. Fan speed: 2400 r.p.m.Sound volume: 41.0 dB(A) Maximum operating temperature 50ºC.Protection Rating: - IPx4Graph for UAX-ES150 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)Mains voltage modelsExtract volume 295m 3 /hSound volume 41.0dB (A)@3mVoltage230v AC~Frequency50 HzWattage26WMax Temp50 o CWeight0.92 kgMax Pressure 80paWindow FittingDiameter of hole: 175 mmWall Hole162 mmADUnit DimensionsA210mmB210mmBØCDØ114mm30mm152mmC<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>UAX-ES100 Range: 230v and 12vThe UAX-ES100 range of 100mm (4") bathroomand toilet fans comprises quiet, efficient, axial flowfans for wall, ceiling or window mounting.Designed for easy installation, attractively styled inhigh gloss ABS thermoplastics for modernappearance and ease of cleaning andincorporating the latest technology and design.The units have silently operating electricshutters controlled by a well proven thermoelectricactivator. These shutters are designed toeliminate back-draught.The UAX-ES100 series is ideally suited for domestic applications includingbathrooms, toilets and shower areas. The range also includes 12v Low Voltagemodels for use when required.Extract rate 99m³/hr,27 litres per secondFans can be wall,ceiling or windowmountedBritish madeDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to complywith HD280/BS3456Part 102:342 19882 year no quibbleguaranteeTechnical Data230v modelsLow Voltage 12v modelsCatalogue No. Catalogue No. TypeUAX-ES100 UAX-ES100LV Standard model - for remote switching.UAX-ES100S UAX-ES100LVS As above supplied with Pullcord switch.UAX-ES100T UAX-ES100LVT Timer model - with integral over-run timer (15 mins).UAX-ES100HTS UAX-ES100LVHTS Humidity control - The fan will run when humidity rises overthe pre-set level of 65% RH. Complete with integral timer (15mins) and Pullcord switch.ConstructionElectricalThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted and mounted a minimum of1.75 metres from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


MotorGuaranteeInstallationPerformanceAdditional DataSingle phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.Both 230v and 12v ranges are designed to be wall, window or ceiling mounted. Kitsavailable on request.Wall kits comprise a wall sleeve (275mm long) and an external fixed grille (white,terracotta, stone, grey or brown)Window kits comprise an external white fixed grille and internal fixing plate.Ceiling kits comprise 3m 100mm flexible ducting and an external fixed grille (coloursto suit)Installation through a wall or ceiling requires a 107mm hole, through a window a130mm hole.UAX-ES100 / UA-ES100LV - extract rate of 98m³/hr, 27 litres per second.Maximum pressure: 35 p.a. Fan speed: 2300 r.p.m.Sound volume: 34.0 dB(A) Maximum operating temperature 50ºC.Protection Rating – IPx4Graph for UAX-ES100 / UAX-ES100LV Ranges80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)Mains voltage modelsExtract volume 98m 3 /hSound volume34.0dB (A)@3mVoltage220 - 230v AC~Frequency50 HzWattage20WMax Temp50 o CWeight0.61kgMax Pressure35paWindow FittingDiameter of hole: 125 - 140 mmWall Hole107 mmADUnit DimensionsA166 mmB166 mmBØCD150 mm30 mmØ100 mmC<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>UAX ES1 5 0 Range: 2 3 0 vThe UAX ES150 range of 150mm (6")kitchen fans comprises quiet, efficient,axial flow fans for wall, ceiling, or windowmounting.Designed for easy installation, attractivelystyled in high gloss ABS thermoplastics formodern appearance and ease of cleaningand incorporating the latest technologyand design.The units have silently operating electricshutters controlled by a well proven thermo-electric activator. These shuttersare designed to eliminate back-draughtThe UAX ES 150 series is ideally suited for domestic kitchen applications.Extract rate 295m³/hr, 83litres per secondFans can be wall, ceilingor window mountedBritish madeDesigned to exceed the2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.UAX ES 150UAX ES 150 SUAX ES 150 HTSTypeStandard model - for remote switching.As above supplied with pull switch.Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and pull switch.ConstructionElectricalMotorGuaranteeThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 26 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mmin all poles, must be used with a 3 amp fuse fitted. The fan should be mounted aminimum of 1.75 metres from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator, cooker.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


InstallationPerformanceAdditional DataDesigned to be wall, window or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and an external fixed gravity grille(white, terracotta, stone, grey or brown)Window kits comprise an external white fixed grille and internal fixing plate. Doubleglazedwindow kit supplied as standard. For single-glazed windows, request special kitwhen ordering.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille (colours tosuit)Installation through a wall or ceiling requires a 162mm hole, through a window a175mm hole.UAX-ES150 - extract rate of 295m³/hr, 83 litres per second.Maximum pressure: 80 p.a. Fan speed: 2400 r.p.m.Sound volume: 41.0 dB(A) Maximum operating temperature 50ºC.Protection Rating: - IPx4Graph for UAX-ES150 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)Mains voltage modelsExtract volume 295m 3 /hSound volume 41.0dB (A)@3mVoltage230v AC~Frequency50 HzWattage26WMax Temp50 o CWeight0.92 kgMax Pressure 80paWindow FittingDiameter of hole: 175 mmWall Hole162 mmADUnit DimensionsA210mmB210mmBØCDØ114mm30mm152mmC<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Slim line 1 0 0 Range: 2 3 0 v and 1 2 vThe SLIMLINE range of100mm (4") fans comprisesquiet, efficient, axial flowfans for wall or ceilingmounting. Designed foreasy installation,attractively styled in highgloss ABS thermoplasticsfor modern appearanceand ease of cleaning andincorporating the latesttechnology and design.The SLIMLINE 100 series is ideally suited for domestic applications includingbathrooms, toilets and shower areas.The range is available in 230v and 12v Low Voltage.The fans are extremely aesthetically pleasing as they have a 12mm profile.Fans can be wall orceiling mountedBritish madeDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 1988Aesthetically pleasing2 year no quibbleguaranteeTechnical Data230V modelsCatalogue No.SL 100SL 100 SSL 100 TSL 100 HTSTypeStandard model - for remote switching.As above supplied with integral pull switch.Timer model - with integral over-run timer (15 mins).Humidity control - The fan will run will run when humidity rises over the pre-set level of65% RH. Complete with integral timer (15 mins) with manual pull switch.Low Voltage 12v models:Catalogue No.SL 100 LVSL 100 LV SSL 100 LV TSL 100 LV HTSTypeStandard model - for remote switching.As above supplied with integral manual pullswitch.Timer model - with integral over-run timer (15 mins).Humidity control - The fan will run will run when humidity rises over the pre-set level of65% RH. Complete with integral timer (15 mins) and manual pullswitch.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMay 11


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics forstrength, durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 14 watts. These fans aredouble insulated and do not require an earth. All wiring must comply withcurrent IEE regulations. A double pole isolating switch, having a contactseparation of at least 3mm in all poles, must be used with a 3 amp fuse fittedand mounted a minimum of 1.75 metres from the floor and less than 400mmfrom the ceiling.Do not install the fans above a heat source. e.g. cooker, radiator.Single phase induction motor with pre-oiled bearings fitted for a longmaintenance free <strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.Both 230v and 12v ranges are designed to be wall or ceiling mounted. Kitsavailable on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white,terracotta, stone, grey or brown).Ceiling kits comprise 3m 100mm flexible ducting and an external fixed grille(colours to suit).Installation through a wall or ceiling requires a 107mm hole.SL100 / SL100LV - extract rate of 90m³/hr, 27 litres per second.Maximum pressure: 38 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IP34.Graph for Slimline 100 and Slimline 100 Low Voltage Ranges80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)ADAB150 mm150 mmØ100 mmBØCD108 mm12 mmHole sizes:wall/ceiling107 mmC<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMay 11


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Slimline 150 RangeThe SLIMLINE range of 150mm (6”) fanscomprises quiet, efficient, axial flow fans forwall or ceiling mounting. Designed for easyinstallation, attractively styled in high glossABS thermoplastics for modern appearanceand ease of cleaning and incorporating thelatest technology and design.The SLIMLINE series is ideally suited fordomestic applications including kitchens.The ranges are available in 230v fans.The fans are extremely aesthetically pleasing as they have a 12mm profile.Technical DataFans can be wall orceiling mountedBritish madeDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 1988Aesthetically pleasing2 year no quibbleguarantee230v models:Catalogue No.SL150SL150 SSL150 TSL150 HTSTypeStandard model - for remote switching.As above supplied with integral pull switch.Timer model - with integral over-run timer switch (15 mins).Humidity control - The fan will run will run when humidity rises over the pre-set level of65% RH. Complete with integral timer (15 mins) and manual pull switch.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics forstrength, durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 24 watts. These fans aredouble insulated and do not require an earth. All wiring must comply withcurrent IEE regulations. A double pole isolating switch, having a contactseparation of at least 3mm in all poles, must be used with a 3 amp fuse fittedand mounted a minimum of 1.75 metres from the floor and less than 400mmfrom the ceiling.Do not install the fans above a heat source. e.g. cooker, radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenancefree <strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The ranges is designed to be wall or ceiling mounted. Kits available onrequest.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white,terracotta, stone, grey or brown).Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille(colours to suit).Installation through a wall or ceiling requires a 162 mm hole.SL150 - extract rate of 294m³/hr, 82 litres per second.Maximum pressure: 87 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IP34.Graph for Slimline 150 Range9080706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)ADABØ205 mm205 mm150 mmBØCDHole sizes:150 mm15 mmwall/ceiling162 mmC<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic 400: 230vThe Sensortronic range of100mm (4") bathroom and toiletfans comprises quiet, efficient,axial flow fans for wall, ceiling orwindow mounting.Designed for easy installation,attractively styled in high glossABS thermoplastics for modernappearance, ease of cleaning,incorporating the latesttechnology and design offering atwo year no quibble guarantee.The Sensortronic series is ideally suited for domestic applications includingbathrooms, toilets and shower areas. All units can be Wall Window & ceilingmounted. Installation kits available to suit with colour options of Brown, White,Grey, Stone and Terracotta.Extract rate 90m³/hr, 27litres per secondFans can be wall, ceilingor window mountedBritish madeDesigned to exceed the2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.TypeS400HT Humidity Control – The fan will run when the humidity rises above the preset level of 65%RH. Complete with integral timer (15min).S400HS Humidity Control – The fan will run when the humidity rises above the preset level of 65%RH. Complete with integral Pullcord switch.ConstructionElectricalMotorGuaranteeThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mmin all poles, must be used with a 3 amp fuse fitted and mounted a minimum of 1.75meters from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


InstallationPerformanceAdditional DataThe range is designed to be wall, window or ceiling mounted. Kits available onrequest.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m of 100mm flexible ducting and an external fixed grille(colours to suit).When installing through a wall a 107mm hole is required, 126mm through a window.S400 - extract rate of 90m³/hr, 27 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IPx4Unit Dimensions & cutoutsF 166G 166H 100J 42K 42Hole sizes:wall / ceiling 107mmwindow 126mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageLowVoltageNoise levelWarrantyFanSpeedColourSelf-cleaningsensorMaxpressureDigitaldisplaySpeedoptionsDownloadfacility90m 3 /h27ltrs/sec220/230 20 No 40db 2 year RTB 2400 White No 50 p.a. No No NoNOTES:* Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic 10 0 0 : 2 3 0 vThe Sensortronic 1000 150mm (6")kitchen fan comprises a quiet, efficient,axial flow fan for wall, ceiling or windowmounting. Designed for easy installation,attractively styled in high gloss ABSthermoplastics for modern appearanceand ease of cleaning and incorporatingthe latest technology and design.Extract rate 235m³/hr,64 litres per secondFans can be wall,ceiling or windowmountedIntegral speedadjustmentBritish madeThe Sensortronic 1000 series is ideally suited for domestic kitchen applications. Itfeatures an integral pullcord and <strong>Ferrob</strong>'s unique electronic continuously-calibratedhumidity sensor which ensures that the sensor will always give an accurate readingof the surrounding humidity.The units are controlled using the latest micro-processor technology and hasfeatures such as Night-time Set-back to eliminate unnecessary running at nightand integral pullswitch.A 2-light display is included on the front panel which informs the resident what thefan is doing (yellow and red lights). The yellow light will show when the unit isrunning due to a high humidity level and the red light when the unit is in manualoperation.ElectroniccontinuouslycalibratedhumiditysensorDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.S 1000TypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral pull switch and the unique electronic continuously-calibrated humiditysensor.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durabilityand finish.220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulatedand do not require an earth. All wiring must comply with current IEE regulations. A doublepole isolating switch, having a contact separation of at least 3mm in all poles, must be usedwith a 3 amp fuse fitted. The fan should be mounted a minimum of 1.75 metres from the floorand less than 400mm from the ceiling.Do not install the fan above a heat source, e.g. cooker or radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong> andprotected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be wall, window or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta, stone,grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille (colours to suit).When installing through a wall or ceiling a 162mm hole is required, 175mm through awindow.S 1000 - extract rate of 235m³/hr, 64 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IPx4Unit Dimensions & cutoutsA 206B 206C 150D 42E 54Hole sizes:Wall / ceiling 162mmWindow 175mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageNoiselevelWarrantyFan Speed ColourElectronicrecalibratingsensorMax pressureDigitaldisplaySpeedoptionsDownloadfacility235m 3 /h64ltrs/sec220/230 2040db at fullspeed2 year RTB2400 at fullspeedWhite Yes 50 p.a. No Yes NoNOTES:Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


Graph for Sensortronic 1000 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic Micro 400: 230v and 12vExtract rate90m³/hr, 27 litresper secondFans can be wall,ceiling or windowmountedBritish madeThe Sensortronic Micro 400 range of 100mm (4") bathroom and toilet fanscomprises quiet, efficient, axial flow fans for wall, ceiling or window mounting.Designed for easy installation, attractively styled in high gloss ABS thermoplasticsfor modern appearance and ease of cleaning and incorporating the latesttechnology and design.The M 400 series is ideally suited for domestic applications including bathrooms,toilets and shower areas.The units are controlled using the latest micro-processor technology and hasfeatures such as Night-time Set-back to eliminate unnecessary running at nightand incorporates <strong>Ferrob</strong>'s unique humidity sensor. The humidity level can be readusing a hand held monitor, part no: 1500 (available separately)Designed to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to complywith HD280/BS3456Part 102:342 19882 year no quibbleguaranteeThe range also includes 12v Low Voltage models for use when required.Technical Data230v modelsCatalogue No.TypeM 400 HT Humidity Control – The fan will run when the humidity rises above the pre-set level of 65%RH. Complete with integral timer (15min)M 400 HS Humidity Control – The fan will run when the humidity rises above the pre-set level of 65%RH. Complete with integral pull switch.Low Voltage 12v modelsCatalogue No.M 400 LV HTM 400 LV HSTypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins).Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral pull switch<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan07


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional Data:These fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted mounted a minimum of 1.75meters from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiatorSingle phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.The range is designed to be wall, window or ceiling mounted. Kits available onrequest.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m of 100mm flexible ducting and an external fixed grille(colours to suit).When installing through a wall a 107mm hole is required, 126mm through a window.M 400 / M 400 LV - extract rate of 90m³/hr, 27 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating: - IPx4Unit Dimensions & cut-outsF 166G 166H 100J 42K 42Hole sizes:wall / ceiling 107mmwindow 126mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageLowVoltageNoise levelWarrantyFanSpeedColourSelf-cleaningsensorMaxpressureDigitaldisplaySpeedoptionsDownloadfacility90m 3 /h27ltrs/sec220/230 20 Yes 40db 2 year RTB 2400 White No 50 p.a. No No NoNOTES:* Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic 10 0 0 : 2 3 0 vThe Sensortronic 1000 150mm (6")kitchen fan comprises a quiet, efficient,axial flow fan for wall, ceiling or windowmounting. Designed for easy installation,attractively styled in high gloss ABSthermoplastics for modern appearanceand ease of cleaning and incorporatingthe latest technology and design.Extract rate 235m³/hr,64 litres per secondFans can be wall,ceiling or windowmountedIntegral speedadjustmentBritish madeThe Sensortronic 1000 series is ideally suited for domestic kitchen applications. Itfeatures an integral pullcord and <strong>Ferrob</strong>'s unique electronic continuously-calibratedhumidity sensor which ensures that the sensor will always give an accurate readingof the surrounding humidity.The units are controlled using the latest micro-processor technology and hasfeatures such as Night-time Set-back to eliminate unnecessary running at nightand integral pullswitch.A 2-light display is included on the front panel which informs the resident what thefan is doing (yellow and red lights). The yellow light will show when the unit isrunning due to a high humidity level and the red light when the unit is in manualoperation.ElectroniccontinuouslycalibratedhumiditysensorDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.S 1000TypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral pull switch and the unique electronic continuously-calibrated humiditysensor.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durabilityand finish.220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulatedand do not require an earth. All wiring must comply with current IEE regulations. A doublepole isolating switch, having a contact separation of at least 3mm in all poles, must be usedwith a 3 amp fuse fitted. The fan should be mounted a minimum of 1.75 metres from the floorand less than 400mm from the ceiling.Do not install the fan above a heat source, e.g. cooker or radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong> andprotected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be wall, window or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta, stone,grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille (colours to suit).When installing through a wall or ceiling a 162mm hole is required, 175mm through awindow.S 1000 - extract rate of 235m³/hr, 64 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IPx4Unit Dimensions & cutoutsA 206B 206C 150D 42E 54Hole sizes:Wall / ceiling 162mmWindow 175mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageNoiselevelWarrantyFan Speed ColourElectronicrecalibratingsensorMax pressureDigitaldisplaySpeedoptionsDownloadfacility235m 3 /h64ltrs/sec220/230 2040db at fullspeed2 year RTB2400 at fullspeedWhite Yes 50 p.a. No Yes NoNOTES:Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


Graph for Sensortronic 1000 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan08


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic Digital 4 0 0 : 2 3 0 v and 1 2 vExtract rate 90m³/hr,27 litres per secondFans can be wall,ceiling or windowmountedBritish madeThe Sensortronic Digital 400 range of 100mm (4") bathroom and toilet fans comprises quiet,efficient, axial flow fans for wall, ceiling or window mounting. Designed for easy installation,attractively styled in high gloss ABS thermoplastics for modern appearance and ease ofcleaning and incorporating the latest technology and design.The D400 series is ideally suited for domestic applications including bathrooms, toilets andshower areas. They feature an integral pull switch or timer and <strong>Ferrob</strong>'s unique electroniccontinuously-calibrated humidity sensor which ensures that the sensor will always give anaccurate reading of the surrounding humidity.The units are controlled using the latest micro-processor technology and also has the NighttimeSet-back to eliminate unnecessary running at night.The range also includes 12v Low Voltage models for use when required.The fans have a digital display on the front panel which continuously informs the resident of whatthe fan is doing.ElectroniccontinuouslycalibratedhumiditysensorDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.D 400 HTD 400 HSTypeHumidity Control – The fan will run when the humidity rises above the pre-set level of 65% RH. Completewith integral timer (15min)Humidity Control – The fan will run when the humidity rises above the pre-set level of 65% RH. Completewith integral Pullcord switch.Low Voltage 12v modelsCatalogue No.D 400 LV HTD 400 LV HSTypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH. Complete withintegral timer (15 mins).Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH. Complete withintegral pull switch<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability andfinish.220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are double insulated and donot require an earth. All wiring must comply with current IEE regulations. A double pole isolatingswitch, having a contact separation of at least 3mm in all poles, must be used with a 3 amp fusefitted and mounted a minimum of 1.75 metres from the floor and less than 400mm from the ceiling.Do not install above a heat source, e.g. radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong> andprotected by a thermal fuse.Two year no quibble guarantee.The range is designed to be wall, window or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta, stone, grey orbrown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m of 100mm flexible ducting and an external fixed grille (colours to suit).When installing through a wall a 107mm hole is required, 126mm through a window.D 400 / D 400 LV - extract rate of 90m³/hr, 27 litres per secondMaximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB (A). Maximum operating temperature 40ºC.Protection Rating: IPx4. Power Consumption: 20WRunning Costs: typ less than 80p per month (based on max 8hrs running per day)Unit Dimensions & cut-outsF 166G 166H 100J 42K 42Hole sizes:wall / ceiling107mmwindow126mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageLowVoltageNoise level WarrantyFanSpeedColourElectronicrecalibratingsensorMaxpressureDigitaldisplaySpeedoptionsDownloadfacility90m 3 /h27ltrs/sec220/230 20 Yes 40db 2 year RTB 2400 White Yes 50 p.a. Yes No NoNOTES:* Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


Graph for Digital 400 / 400LV Ranges80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic Digital 1 0 0 0 : 2 3 0 vThe Sensortronic Digital 1000 150mm(6") kitchen fan comprises a quiet,efficient, axial flow fan for wall, ceilingor window mounting.Designed for easy installation,attractively styled in high gloss ABSthermoplastics for modernappearance and ease of cleaning andincorporating the latest technologyand design.The Digital 1000 is ideally suited for domestic kitchen applications. It features anintegral pullcord and <strong>Ferrob</strong>'s unique electronic continuously-calibrated humiditysensor which ensures that the sensor will always give an accurate reading of thesurrounding humidity.The units are controlled using the latest micro-processor technology and hasfeatures such as Night-time Set-back to eliminate unnecessary running at nightand integral pullswitch.The fans have a digital display on the front panel which continuously informsthe resident of what the fan is doing.Extract rate 235m³/hr, 64litres per secondFans can be wall, ceilingor window mountedIntegral speed switchBritish madeElectronic continuouslycalibratedhumiditysensorDesigned to exceed the2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.TypeD 1000 Humidity control - The fan will run when humidity rises over the pre-set level of 65%RH. Complete with integral pullcord switch and the unique electronic continuouslycalibratedhumidity sensor.ConstructionElectricalThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not beaccessible to a person using either the shower or the bath and mounted a minimumof 1.75 meters from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. cooker or radiator.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


MotorGuaranteeInstallationPerformanceAdditional DataSingle phase induction motor with pre-oiled bearings fitted for a long maintenance free<strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be wall, window or ceiling mounted. Kits available onrequest.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille(colours to suit).When installing through a wall or ceiling a 162mm hole is required, 175mm througha windowD 1000 - extract rate of 235m³/hr, 64 litres per second.Maximum pressure: 50 p.a.Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A)Maximum operating temperature 40ºC.Protection Rating: IPx4Power Consumption: 20WRunning Costs: typ less than 80p per month (based on max 8hrs running per day)Unit Dimensions & cutoutsA 206B 206C 150D 42E 54Hole sizes:wall / ceiling 162mmwindow 175mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageNoiselevelWarrantyFan Speed ColourElectronicrecalibratingsensorMax pressureDigitaldisplaySpeedoptionsDownloadfacility235m 3 /h64ltrs/sec220/230 2040db at fullspeed2 year RTB2400 at fullspeedWhite Yes 50 p.a. Yes Yes NoNOTES:Specification dependent on modelGraph for Digital 1000 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic Logic 4 0 0 : 2 3 0 v and 1 2 vExtract rate 90m³/hr,27 litres per secondFans can be wall,ceiling or windowmountedBritish madeThe Sensortronic Logic 400 range of 100mm (4") bathroom and toilet fanscomprises quiet, efficient, axial flow fans for wall, ceiling or window mounting.Designed for easy installation, attractively styled in high gloss ABS thermoplasticsfor modern appearance and ease of cleaning and incorporating the latesttechnology and design.The L400 series is ideally suited for domestic applications including bathrooms,toilets and shower areas. They feature an integral pullcord or timer and <strong>Ferrob</strong>'sunique electronic continuously-calibrated humidity sensor which ensures that thesensor will always give an accurate reading of the surrounding humidity.The units are controlled using the latest micro-processor technology and also hasthe Night-time Set-back to eliminate un-necessary running at night. The range alsoincludes 12v Low Voltage models for use when required.ElectroniccontinuouslycalibratedhumiditysensorDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to complywith HD280/BS3456Part 102:342 19882 year no quibbleguaranteeThe fans have a digital display on the front panel which continuously informs the resident of what the fan isdoing.A unique feature of the Logic range is the capability of the fans to store the last12 months humidity, temperature and set-point readings. This data can then bedownloaded from the fans using a laptop computer (running Windows o/s) andevaluated.The download software for the PC can be downloaded by clicking this link.The caption opposite shows the data format when read on the PC.Technical Data230v modelsCatalogue No.TypeL 400 HT Humidity Control – The fan will run when the humidity rises above the pre-set level of 65%RH. Complete with integral timer (15min)L 400 HS Humidity Control – The fan will run when the humidity rises above the pre-set level of 65%RH. Complete with integral pull switch.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


Low Voltage 12v modelsCatalogue No.L 400 LV HTL 400 LV HSTypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins).Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral pull switchConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional Data:These fans are moulded in impact resistant high gloss ABS thermoplastics forstrength, durability and finish.220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans aredouble insulated and do not require an earth. All wiring must comply withcurrent IEE regulations. A double pole isolating switch, having a contactseparation of at least 3mm in all poles, must be used with a 3 amp fuse fittedmounted a minimum of 1.75 metres from the floor and less than 400mm fromthe ceiling.Do not install above a heat source, e.g. radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenancefree <strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The range is designed to be wall, window or ceiling mounted. Kits availableon request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white,terracotta, stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m of 100mm flexible ducting and an external fixed grille(colours to suit).When installing through a wall a 107mm hole is required, 126mm through awindow.L 400 / L 400 LV - extract rate of 90m³/hr, 27 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IPx4Unit Dimensions & cutoutsF166 mmG166 mmH100 mmJ42 mmK42 mmHole sizes:wall / ceiling 107mmwindow 126mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageLowVoltageNoise level WarrantyFanSpeedColourElectronicrecalbratingsensorMaxpressureDigitaldisplaySpeedoptionsDownloadfacility90m 3 /h27ltrs/sec220/230 20 Yes 40db 2 year RTB 2400 White Yes 50 p.a. Yes No YesNOTES:* Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


Graph for Logic 400 / 400LV Ranges80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Sensortronic Logic 1 0 0 0 : 2 3 0 vExtract rate 235m³/hr, 64litres per secondFans can be wall, ceiling orwindow mountedIntegral speed adjustmentBritish madeElectronic continuouslycalibratedhumidity sensorThe caption above shows the data format when read on the PC.The Sensortronic Logic 1000 150mm (6") kitchen fan comprises a quiet,efficient, axial flow fan for wall, ceiling or window mounting. Designed foreasy installation, attractively styled in high gloss ABS thermoplastics formodern appearance and ease of cleaning and incorporating the latesttechnology and design.The Logic 1000 is ideally suited for domestic kitchen applications. It featuresan integral pullcord and <strong>Ferrob</strong>'s unique electronic continuously-calibratedhumidity sensor which ensures that the sensor will always give an accuratereading of the surrounding humidity.Designed to exceed the2006 Building Regulationson Ventilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeThe units are controlled using the latest micro-processor technology and has features such as Night-time Setbackto eliminate un-necessary running at night and integral pullswitch.The fans have a digital display on the front panel which continuously informs the resident of what the fan isdoing.A unique feature of the Logic range is the capability of the fans to store the last 12 months humidity, temperatureand set-point readings. This data can then be downloaded from the fans using a laptop computer (runningWindows o/s) and evaluated.Technical Data230v modelsCatalogue No.L 1000TypeHumidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral Pullcord switch and unique electronic continuously-calibratedhumidity sensor.ConstructionThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


ElectricalMotorGuaranteeInstallationPerformanceAdditional Data220-230v ~ A.C. 50Hz Single phase consuming 20 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted. The fan should be mounteda minimum of 1.75 metres from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source, e.g. cooker or radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free<strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be wall, window or ceiling mounted. Kits available onrequest.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Window kits comprise an external white gravity grille and internal fixing plate.Ceiling kits comprise 3m 150mm flexible ducting and an external fixed grille (coloursto suit).When installing through a wall or ceiling a 162mm hole is required, 175mm througha window.L 1000 - extract rate of 235m³/hr, 64 litres per second.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.Protection Rating – IPx4Unit Dimensions & cut outsA 206B 206C 150D 42E 54Hole sizes:wall / ceiling 162mmwindow 175mmSPECIFICATIONExtract rate atfull speedSupplyvoltageMaxwattageNoiselevelWarrantyFan Speed ColourElectronicrecalibratingsensorMax pressureDigitaldisplaySpeedoptionsDownloadfacility235m 3 /h64ltrs/sec220/230 2040db at fullspeed2 year RTB2400 at fullspeedWhite Yes 50 p.a. Yes Yes YesNOTES:Specification dependent on model<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


Graph for Logic 1000 Range80706050Pressure (Pa) 4030201000 50 100 150 200 250 300 350Extract Capacity (m3/hr)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Centrifugal 1 0 0 Range for bathroom s and toilets: 2 3 0 v and 1 2 vExtract rate 90m³/hr,27 litres per secondFans can be wall orceiling mountedBritish madeDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)The CF 100 range of 100mm (4") bathroom and toilet fans comprises efficient,centrifugal flow fans for wall or ceiling mounting. Designed for easy installation,attractively styled in high gloss ABS thermoplastics for modern appearance and easeof cleaning and incorporating the latest technology and design.The CF 100 series is ideally suited for domestic applications where higher backpressures are present. These are normally associated where flat ducting or longlengths of circular ducting are used.Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeThe range also includes 12v Low Voltage models for use when required.Technical Data230v modelsCatalogue No.CF 100CF 100 SCF 100 TCF 100 HTSCF 100 TRSCF 100TRSTTypeStandard model - for remote switching.As above supplied with integral pull switch.Timer model - with integral over-run timer (15 mins).Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and pull switch.Continuously running trickle speed with pull switch boost.Continuously running trickle speed with remote boost.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan10


Low Voltage 12v modelsCatalogue No.CF 100 LV SCF 100 LV TCF 100 LV TRSCF 100 LV HTSTypeWith pull switch.Timer model with integral over-run timer switch (15 mins).Continuously running trickle speed with pull switch boost.Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and pull switch.ConstructionElectricalMotorGuaranteeThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 38 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted. The fan should not beaccessible to a person using either the shower or the bath and mounted a minimumof 1.75 meters from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free<strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.PerformanceInstallationAdditional DataCF 100/CF 100 LV 90m³/hr, 27 litres/secBoth 230v and 12v ranges are designed to be wall or ceiling mounted. Kits availableon request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Ceiling kits comprise 3m 100mm flexible ducting and an external fixed grille (coloursto suit).A full range of flat/round duct accessories are available - contact sales@ferrob.co.ukfor information.Installation through a wall or ceiling requires a 107mm hole.Maximum pressure: 108 p.a. see graph below.Fan speed: 1100rpmSound volume: 38.0 dB(A)Maximum operating temperature 50ºC.Protection Rating: IPx4Power Consumption: 20WRunning Costs: typ less than 20p per month (based on max 4hrs running per day)Unit Dimensions & Cut-outsABCØWall HoleCeiling Hole230mm20mm105mm97mm107mm107mm<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan10


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Centrifugal CF200 Range for kitchens: 230vThe CF200 range of 100mm (4") kitchenfans comprises efficient, centrifugal flowfans for wall or ceiling mounting.Designed for easy installation,attractively styled in high gloss ABSthermoplastics for modern appearanceand ease of cleaning and incorporatingthe latest technology and design.The CF200 series is ideally suited fordomestic applications where higherback pressures are present. These arenormally associated where flat ducting or long lengths of circular ducting are used.Extract rate 260m³/hr,73 litres per secondFans can be wall orceiling mountedBritish madeDesigned to exceedthe 2006 BuildingRegulations onVentilation (F1)Tested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230v modelsCatalogue No.CF200CF200SCF200TCF200HTSCF200TRSTypeStandard model - for remote switching.As above supplied with Pullcord switch.Timer model - with integral over-run timer (15 mins).Humidity control - The fan will run when humidity rises over the pre-set level of 65% RH.Complete with integral timer (15 mins) and Pullcord switch.Continuously running trickle speed with Pullcord boost switch.ConstructionElectricalThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 88 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least3mm in all poles, must be used with a 3 amp fuse fitted and mounted a minimum of1.75 metres from the floor and less than 400mm from the ceiling.Do not install the fan above a heat source. e.g. radiator.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


MotorGuaranteeInstallationPerformanceAdditional DataSingle phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong>and protected by a thermal fuse.Two year no quibble guarantee.The range is designed to be wall or ceiling mounted. Kits available on request.Wall kits comprise a wall sleeve (275mm long) and a gravity grille (white, terracotta,stone, grey or brown).Ceiling kits comprise 3m 100mm flexible ducting and an external fixed grille (coloursto suit).A full range of flat/round duct accessories are available - contact sales@ferrob.co.ukfor information.CF200 - extract rate of 260m³/hr, 73 litres per second (through wall measurement).Maximum pressure: 363 p.a. see graph below. Fan speed: 2400 r.p.m.Sound volume: 41.0 dB(A) Maximum operating temperature 50ºC.Protection Rating: - IPx4Unit Dimensions & CutoutsABCØWall HoleCeiling Hole265mm20mm115mm97mm107mm107mm<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Positive Pressure ( Aridair) UnitsExtract rate 55 litres/secfast speed, 44 litres/ secslow speedCan be loft or cupboardmountedBritish madeS3000LWFlat UnitS2000LWLoft Unit2 year no quibbleguaranteeThe Aridair range of units has been developed to eliminate moisture from thehome by a constant circulation of gently pressurized clean air.Mounted either in the loft area of a house or a hallway cupboard or a flat, the gentle pressurization of theproperty expels any stale, humid air through natural ventilation points which are present in even the mostinsulated buildings.The Aridair S 2000 LW - for mounting in a loft area. The unit is manually-operated and has 2 switches (on-offand slow-fast)The Aridair S 2000 NI – for mounting in a loft area. The unit runs continuously on slow speed with an automaticsummer / winter cut-out.The Aridair Micro 2000 - for a loft area is supplied with <strong>Ferrob</strong>'s unique self-cleaning humidity sensor. Thissensor unit can be mounted in the kitchen to continually monitor the level of humidity in the air.The unit runs continuously on slow speed and when the sensor detects a level of humidity above the switch-onpoint (65% RH), the unit is switched to fast speed.Once the level has fallen below the pre-set level, the unit will revert torunning on trickle speed.Up to 4 humidity sensors can be fitted around the home all connected backto the main unit to ensure total control.The sensor unit also has an automatic summer / winter cut-out which meansthe unit will not run on trickle speed if the loft temperature is above 25 deg Cin the summer or 5 deg C in the winter. However, the sensor will still run theunit in fast speed when the switch-on point is reached.The Aridair S3000LW - for mounting on the wall of a property without a loft.Similar in its operation to the S2000LW (for lofts) except that air is brought<strong>into</strong> the unit through ducting and then discharged to the property via a grille.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan09


Technical DataLoft mounted models for properties with loftsCatalogue No.S 2000 LWS 2000 NIM 2000TypeLow Wattage with 2-speed manually-operated switch.Continuous trickle speed with summer / winter temperature cut-out.Humidity control - continuous trickle speed and will run in fast speed when humidity risesover the pre-set level of 65% RH. Humidity level detected using remote humidity sensor.(1no supplied with the unit)Cupboard mounted model for properties without loftsCatalogue No.S 3000 LWTypeLow Wattage with 2-speed manually-operated switch.Filters are fitted to all units to remove dust and dirt particles and prevent them from entering the home.The air is discharged to the property either through a centrally located inlet grille mounted on the landing orhallway ceiling for the loft-mounted units or wall grille for the cupboard-mounted unit.ConstructionElectricalMotorGuaranteeInstallationPerformanceAdditional DataThese units are made in leather-coated steel for strength, durability and finish.220-230V ~ A.C. 50Hz Single phase consuming max 70 watts for the M2000,S2000NI and M2000NI, max 27 watts for the S2000 LW and max 13 watts for theS3000 LW. These units require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mmin all poles, must be used with a 3 amp fuse fitted.Single phase induction motor with pre-oiled ball-bearings fitted for a long maintenancefree <strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be loft or cupboard mounted. The inlet grille must bemounted at least 1m from any smoke detectors but full installation and operatinginstructions are provided with each unit.S 2000LW /M 2000 /S 3000LW - supply rate of 44 litres/sec on slow speed and 55 l/son fast.Fan speed: 2400 r.p.m.Sound volume: 25.0 dB(A) Maximum operating temperature 40ºC.Positive pressure units are not included in the 2006 edition of the Building Regulationsas a means to satisfying Building Regs.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan09


SPECIFICATION - M2000 / S2000NI / M2000NI FOR HOMES WITH LOFTSSupply rate(full/trickle)55ls/44lsSupplyvoltage220/230v50HzMaxwattageS2000 Low Wattage FOR HOMES WITH LOFTSNoise level(full speed)WarrantyColourSelf-cleaningsensorSpeedoptions30 slow2 speed25dBA 2 year RTB Grey Yes70 fast auto220/230v55ls/44ls6 slow2 speed25dBA 2 year RTB Grey NoSPECIFICATION - 50Hz S3000 Low Wattage 27 fast FOR HOMES WITHOUT LOFTSmanualSupply rate(full/trickle)SupplyvoltageMaxwattageNoise level(full speed)WarrantyColourSelf-cleaningsensorSpeedoptionsMaxpressure50 p.a.50 p.a.Maxpressure55ls/44ls220/230v50Hz3 slow13 fast20dBA 2 year RTB Grey No2 speedmanual50 p.a.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan09


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>The heat recovery units for single rooms havebeen specifically designed to eliminateexcessive moisture and so helping to preventcondensation with the inherent risks to propertyand health whilst retaining up to 80% of heatcontained within the outgoing air.The range is available in 230v or 12v modelsdepending upon installation criteria. All modelsrun continuously on trickle speed and havevarious options to change to fast speed - seemodel table below. Mounting Kits Available inBrown, White, Terracotta and StoneAll units are manufactured to have balanced airflow so as not to interfere withconventional gas boilers / heating systems where negative air pressure within aproblem may cause a problem.Wall, Window or CeilingmountedIntegral HumiditySensorsEnergy saving manualPullcord override2 year no quibbleguaranteeRecovers up to 80% ofheat that would otherwisebe lostSimple InstallationTechnical Data230V modelsCatalogue No.HR 100HR 100 SHR 100 HSType2-speed, selectable upon installation2-speed, pull switch boost2-speed, humidity sensor and pull switch boostLow Voltage 12v modelsCatalogue No.HR 100 LV SHR 100 LV THR 100 LV HTSTypelow voltage 2-speed, boost by remote switch (not supplied).low voltage 2-speed, pull switch boostlow voltage 2-speed, humidity sensor / timer or pull switch boost<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukAug 11


ConstructionElectricalInstallationAdditional DataThese units are made of strong and durable self-extinguishing plastic for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 15 - 40 watts. These units do not requirean earth. All wiring must comply with current IEE regulations. A double pole isolatingswitch, having a contact separation of at least 3mm in all poles, must be used with a 3amp fuse fittedBoth 230v and 12v ranges are designed to be wall, window or ceiling mounted. Kitsavailable on request.Installation through a wall or ceiling requires a 117mm hole, through a window a126mm hole.Do not install above a heat source e.g. cooker, radiator.It is recommended to change the internal filter on a yearly basis.Maximum Pressure: 30Pa low speed, 80Pa high speedPower Consumption: 15 – 40WSound Volume: 15dBa low speed, 35dBa high speedMaximum Operating Temperature: 55 degrees CProtection rating: IPx4Running Costs: typ less than £1.00 per month (based on slow speed running 24 hoursper day)** see note above on extract air volumes<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukAug 11


<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukAug 11


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>I nfinity W hole HouseHeat Recovery system( I nfinity 9 0 0 0 )Energy SavingDesigned to exceed2010 Building RegsRecovers up to 91%of heat that would beotherwise lost5 year no quibbleguaranteeSimple Installation -weighs only 14Kg(one-man installation)Five airflow settingsto max of 280 m3/hrCan be fitted inside a600mm widecupboardComplete with EU3filtersSFP as low as0.73 w/l/sThe Infinity 9000 whole house mechanical ventilation unit with heat recovery (MVHR) will eradicatecondensation and its damaging effects and provide a cleaner, fresher living <strong>environment</strong> within thedwelling.Stale, moist air is extracted from ‘wet’ rooms through a system of grilles and ducting, passed across a highefficiency heat exchanger to remove heat and the residue is exhausted to the atmosphere.Fresh filtered supply air is drawn across the heat exchanger, warmed by the retained heat in the exchangerand distributed through ceiling mounted grilles to ‘dry’ rooms using 125mm insulated ducting.<strong>Ferrob</strong> recommends using 125mm solid insulated ducting for ‘Best Practice’ results, as recommended bythe Energy Trust.The unit uses the latest energy efficient EC motors which use approximately half the power that is neededfor conventional AC motors. Both the supply and extract filters inside the unit are approved to EU3standards and can be removed and cleaned without dismantling the unit.The unit is SAP Appendix Q listed and can be wired / installed to boost from the remote 5-speed switchsupplied. The remote control unit also has a Summer / Winter switch which prevents the unit from bringingin warm air during the summer.The heat recovery unit is also approved to carry approval B2 for fire retardancy.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk Jan 11


Typical Installation methods / Key featuresTechnical DetailsSound Levels<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk Jan 11


Standard Assessment Procedure – Appendix Q MVHR Product Data 15/04/2011SAP Appendix Q Testing ResultsCentral mechanical supply and exhaust ventilation systempackages with heat recovery used in a single dwellingBrand Name<strong>Ferrob</strong>Model Infinity 9000Model Qualifier (if applicable)Current Manufacturerand Contact DetailsOriginal Manufacturer (if different)Name <strong>Ferrob</strong> Ltd.Regency HouseKingsclere ParkKingsclereAddressNewburyBerksRG20 4SWTelephone 01635 296 716WebsiteFirst Year of Manufacture 2010Last Year of ManufactureTesting Bodywww.ferrob.co.ukBREDate of test 22/03/2010Serial Number of Product TestedMVHR to outside grille duct types and sizeDuct types and sizes used for supply andexhaust5780 EC150 & 125 mm diameter rigidplastic and 200 mm diameter rigidplastic150 & 125 mm diameter rigidplastic and 200 mm diameter rigidplasticResults of leakage testsTable Q1InternalExternalPassPass1 of 3


Standard Assessment Procedure – Appendix Q MVHR Product Data 15/04/2011Results for SAP calculations (at minimum flow rate condition)This product has only been tested with rigid ductwork and the data are not applicablefor SAP calculations if installed with flexible ductwork.Table Q2 – Systems with rigid ductwork onlyExhaust terminalconfigurationKitchen +1 additional wetroomKitchen +2 additional wetroomsKitchen +3 additional wetroomsKitchen +4 additional wetroomsKitchen +5 additional wetroomsFan speedsettingSpecificfanpower(W/l/s)Heatexchangeefficiency(%)Energy SavingTrust Best PracticePerformanceCompliant100%Variable0.73 91 Yes100%Variable0.72 90 Yes100%Variable0.79 89 Yes100%Variable0.93 88 Yes100%Variable1.06 87 NoThese figures are entered <strong>into</strong> either:(a) In the case of SAP software amended to SAP 2005 version 9.81 allowing directentry of MVHR data, the SAP software, or(b) In the case of SAP software amended to SAP 2005 version 9.81 not allowingdirect entry of MVHR data, the SAP Q MVHR Calculation Spreadsheet v9.81 andthe results from the spreadsheet <strong>into</strong> the Special Features part of the SAP 9.81software, or(c) In the case of SAP software to SAP 2005 version 9.80 , the SAP Q MVHRCalculation Spreadsheet v9.80 and the results from the spreadsheet <strong>into</strong> theSpecial Features part of the SAP 9.80 software. They must NOT be entereddirectly <strong>into</strong> SAP 2005 version 9.80 software2 of 3


Standard Assessment Procedure – Appendix Q MVHR Product Data 15/04/2011Table Q3 – Systems with flexible ductwork onlyExhaust terminalconfigurationKitchen +1 additional wetroomFanspeedsettingSpecificfanpower(W/l/s)Heatexchangeefficiency(%)Energy SavingTrust Best PracticePerformanceCompliantN/A N/A N/A N/AThese figures are entered <strong>into</strong> either:(a) In the case of SAP software amended to SAP 2005 version 9.81 allowing directentry of MVHR data, the SAP software, or(b) In the case of SAP software amended to SAP 2005 version 9.81 not allowingdirect entry of MVHR data, the SAP Q MVHR Calculation Spreadsheet v9.81 andthe results from the spreadsheet <strong>into</strong> the Special Features part of the SAP 9.81software, or(c) In the case of SAP software to SAP 2005 version 9.80 , the SAP Q MVHRCalculation Spreadsheet v9.80 and the results from the spreadsheet <strong>into</strong> theSpecial Features part of the SAP 9.80 software. They must NOT be entereddirectly <strong>into</strong> SAP 2005 version 9.80 softwareResults for Approved Document F (at maximum flow rate condition)Table Q4Exhaust terminalconfigurationKitchen +1 additional wet roomKitchen +2 additional wet roomsKitchen +3 additional wet roomsKitchen +4 additional wet roomsKitchen +5 additional wet roomsFan speedsetting100%Variable100%Variable100%Variable100%Variable100%VariableTotal exhaustflow rate(l/s)Total supplyflow rate(l/s)15.0 15.021.0 21.027.0 27.033.0 33.039.0 39.0CommentsOnly figures from Table Q2 or Table Q3, not both, should be used with the SAP QCalculation Spreadsheet for this technology type.Table Q4 results are only applicable for Approved Document F requirements.3 of 3


!∀#∀∃#%∀∃#∀&∀∋%()∗+,(−./01∗∗//(−∗20323140∗5∗6##(78(∗+19:3;#∀#(+>###(∗∗=Α(#%?#(#98(∗0:;19( !∀#∃%&>+2(>%ΒΧ#(#::>∆#;?(


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>I nfinity W hole HouseHeat Recovery system( I nfinity 9 0 0 1 )Energy SavingDesigned to exceed2010 Building RegsRecovers up to 68%of heat that would beotherwise lost5 year no quibbleguaranteeSimple Installation -weighs only 6.5Kg(one-man installation)Five airflow settingsto max of 106 m3/hrCan be void mountedor fitted inside acupboardComplete with EU3filtersThe Infinity 9001 whole house mechanical ventilation unit with heat recovery (MVHR) will eradicatecondensation and its damaging effects and provide a cleaner, fresher living <strong>environment</strong> within thedwelling.Stale, moist air is extracted from ‘wet’ rooms through a system of grilles and ducting, passed across a highefficiency heat exchanger to remove heat and the residue is exhausted to the atmosphere.Fresh filtered supply air is drawn across the heat exchanger, warmed by the retained heat in the exchangerand distributed through ceiling mounted grilles to ‘dry’ rooms using 125mm dia insulated ducting.<strong>Ferrob</strong> recommends using 125mm solid insulated ducting for ‘Best Practice’ results, as recommended bythe Energy Trust.The unit uses the latest energy efficient low-energy motors which use approximately half the power that isneeded for conventional motors. Both the supply and extract filters inside the unit are approved to EU3standards and can be removed and cleaned by removing the top cover of the unit.The unit can be wired / installed to boost from the remote 5-speed switch supplied. The heat recovery unitis also approved to carry approval B2 for fire retardancy.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk Jan 11


Typical Installation methods / Key featuresTechnical Details<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk Jan 11


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong><strong>Ferrob</strong> I nfinity 1 0 0 - Appendix Q approvedDe- centralised Mechanical Extract Ventilation Fans ( d- MEV)1 0 0 m m axial 2 3 0 v / 1 2 vw it h Constant Volum e and Gas Spillage safeThe Infinity100 is a continuouslyrunningextract fan for kitchens andbathrooms and has been tested andapproved to meet current Appendix Qregulations. The product is listed onthe SAP Appendix Q website whichlists approved products.Designed for easy installation,attractively styled in high gloss ABSthermoplastics for modern appearanceand ease of cleaning andincorporating the latest technology anddesign and maintenance free, selflubricatingmotor bearings.Upon installation, the fan needs to beset for its <strong>environment</strong>. By setting theswitch inside the unit to SLOW (bathroom), the fan will maintain the extract rate of 8l/s, orby setting the switch to MEDIUM (kitchen), 13l/s.These are the required extract rates from the latest edition of the Building Regulations,Part F for continuous de-centralised mechanical extract ventilation, System 2.If for any reason, the back-pressure on the fan increases (maybe because of windresistance) the fan will automatically increase the fan speed to maintain the set extractrate.The unit has a ‘best-in-class’ percentage in reduction of airflow when experiencingincreased back pressures, as tested under the SAP Appendix Q conditions. (no morethan 2% drop in airflow @ 5 Pa back pressure)Extract rates of8 / 13 / 19 l/sWall mountedBritish madeDesigned to meetthe 2010 BuildingRegulations onVentilation (F)Tested to complywith HD280/BS3456Part 102:342 19885 year on-sitewarrantyMeets current SAPAppendix QapprovalSFP rating as low as.52 w/l/sWhere there is a danger of spillage from an open-flued appliance, the boost speed hasbeen set to extract at 19l/s, thus eliminating the need for spillage tests to be carried-out.The unit has minimal energy useage by using as little as 1watt when running.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.ukFeb 11


Technical DataCatalogue No.Infinity 100TypeStandard 230v 3-speed (adjustable) 100mm continuously running with integral pullcord boostInfinity 100 RemStandard 230v 3-speed (adjustable) 100mm continuously running with remote switch boostInfinity 100 HInfinity 100 LVStandard 230v 3-speed (adjustable) 100mm continuously running with humidity, pullcord or timer boostSAP Appendix Q listed with Constant Volume and Gas spillage functions as standardStandard 12v 2-speed 100mm continuously running with either pullcord or remote switch boostTo be installed <strong>into</strong> bathrooms to comply with Wiring Regulations.Runs on low speed (8 l/s continuous) and on boost speed (19 l/s) when activated using the pullcord orremote switch.ConstructionMotorGuaranteeInstallationPerformanceAdditional DataThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength, durability and finish.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free <strong>life</strong> and protected bya thermal fuse.5 year on-site warranty.Designed to be wall mounted.Wall kits comprise a wall sleeve (275mm long) and a fixed grille (white, terracotta, stone, grey or brown).Installation through a wall requires a 107mm hole or if using a high-rise internal cowl 117mm.Extract rate of 70m³/hr, 19 litres per second on maximum speed.SAP ratings of .73 w/l/s on slow speed and .52 w/l/s on medium speed.Maximum pressure: 50 p.a. Fan speed: 2400 r.p.m.Sound volume at boost speed: 40.0 dB(A).Maximum operating temperature 40ºC.Protection Rating IPx4.Low speed – 8 l/sec, medium speed – 13 l/sec and full speed – 19 l/sec.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukWebsite: www.ferrob.co.ukFeb 11


Standard Assessment Procedure – Appendix Q Decentralised MEVProduct Data 16/02/2011SAP Appendix Q Test ResultsDecentralised mechanical exhaust ventilation systempackages used in a single dwelling – rigid ductworkBrand Name<strong>Ferrob</strong>Model Infinity 100Model Qualifier (if applicable)Current Manufacturerand Contact DetailsName <strong>Ferrob</strong> Ltd.Regency HouseKingsclere ParkKingsclereAddressNewburyBerksRG20 4SWTelephone 01635 296 716Website www.ferrob.co.ukOriginal Manufacturer (if different)First Year of Manufacture 2011Last Year of ManufactureTesting BodyBREDate of test 08/02/11Serial Number of Product TestedINF100_00001100mm diameter rigid plastic &Ductwork Type and Size100mm rectangular rigid plastic orlarger1 of 3


Standard Assessment Procedure – Appendix Q Decentralised MEVProduct Data 16/02/2011Results for SAP calculations (at minimum flow rate condition)Table Q1 – Systems with rigid ductwork installation onlyThese results are only applicable for SAP Appendix Q if the whole system is installedwith rigid ductwork throughout. If a combination of flexible and rigid ductwork isspecified only results from Table Q3 are applicableUnit configurationLocationFan speedsettingSpecific fan power(W/l/s)In roomKitchen0.5m2.0mR=DR=DWet roomIn duct0.5m KitchenR=D1.0m1.0mR=DWet roomThrough wallKitchen Medium 0.52Wet room Slow 0.73These figures are entered <strong>into</strong> either:(a) In the case of SAP software amended to SAP 2005 version 9.81 and allowingdirect entry of decentralised MEV data, the SAP software, or(b) In the case of SAP software amended to SAP 2005 version 9.81 not allowingdirect entry of decentralised MEV data, the SAP Q Decentralised MEVCalculation Spreadsheet v9.81 for Rigid Ductwork and the results from thespreadsheet <strong>into</strong> the Special Features part of the SAP 9.81 software, or(c) In the case of SAP software to SAP 2005 version 9.80 , the SAP Q DecentralisedMEV Calculation Spreadsheet v9.80 for Rigid Ductwork and the results from thespreadsheet <strong>into</strong> the Special Features part of the SAP 9.80 software.2 of 3


Standard Assessment Procedure – Appendix Q Decentralised MEVProduct Data 16/02/2011Results for Approved Document F (at minimum flow rate condition)Table Q2 – Systems with rigid ductwork installation onlyUnitconfigurationIn roomInductThrough wallLocationFanspeedsettingFlow rate(l/s)Flow rate –windcondition(l/s)% reductionof total flowrate(%)Kitchen - - - -Wet room - - - -Kitchen - - - -Wet room - - - -Kitchen Medium 13.0 >13.0 0Wet room Slow 8.9 8.7 23 of 3


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>I nfinity 9 0 5 0 W hole House Ventilation UnitCentralised Mechanical Extract Ventilation unitAirflow rate325 m3/hr on boostBritish made5 year no quibbleguaranteeAbove void mounted3-speed controllableThe highly successful Infinity range of ventilation products has now beenfurther expanded to include this Centralised Mechanical Extract Ventilationunit to eliminate moisture from the home by a constant extraction of air.Mounted above a ceiling void, slow continuous air movement removes any stale, humid air which is present ineven the most insulated buildings.The units can be supplied with a speed controller for continuous trickle / boost extraction and by using the latestDC motors, very low energy consumption figures have been attained. (41W at fast speed)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukAugust 2011


Technical DataSound LevelsOn slow speed (105 m3/hr) the radiated sound level at 3m is 13dBa.On medium speed (160 m3/hr) the radiated sound level at 3m is 27dBa.On fast speed (325 m3/hr) the radiated sound level at 3m is 34dBa.The unit is currently undergoing SAP Appendix Q approval. When the certificate isreceived it will be posted here. (approx Nov 11)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukAugust 2011


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Airflow rate223 m3/hr on boostAbove void mountedBritish made5 year no quibbleguaranteeThe highly successful Aridair range of ventilation units has now been furtherexpanded to include a new unit which can be used as CentralisedMechanical Extract Ventilation units to eliminate moisture by a constantextraction of air and can be used in domestic <strong>environment</strong>s to treat a singledwelling.Mounted above a ceiling void, slow continuous air movement removes any stale, humid air which is present ineven the most insulated buildings.The units can be boosted by various means. i.e. speed controller, switched live feeds etcAridair S 4000 LW - single speed 223 m3/hr (100mm)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJune 11


Technical DataS4000 LW<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJune 11


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>W hole House Ventilation UnitsCentralised Mechanical Extract Ventilation unitsAirflow rate240 - 553 m3/hr on boostAbove void mountedBritish made5 year no quibbleguaranteeThe highly successful Aridair range of ventilation units has now been furtherexpanded to include 4 units which can be used as Centralised MechanicalExtract Ventilation units to eliminate moisture from the home by a constantextraction of air.Mounted above a ceiling void, slow continuous air movement removes any stale, humid air which is present ineven the most insulated buildings.The units can be supplied with a speed controller for continuous trickle / boost extraction.Aridair S 5000 LW - single speed 240 m3/hr (100mm)Aridair S 6000 LW - single speed 340 m3/hr (125mm)Aridair S 7000 LW - single speed 553 m3/hr (150mm)<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJuly 11


Technical DataS5000LW S6000LW S7000LWDimensions<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJuly 11


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>I nline Duct FansThe in-line range of 100mm (4”) and125mm (5”) duct fans are suitable forkitchen, bathroom and toilet areas andcomprise efficient, mixed-flow, centrifugalfans for mounting within a loft area orboxed-in area at the top of a wall.Designed for easy installation, attractivelystyled in high gloss ABS thermoplasticsfor modern appearance and ease ofcleaning and incorporating the latesttechnology and design.The series is ideally suited for domestic applications where higher back pressuresare present. These are normally associated where flat ducting or long lengths ofcircular ducting are used.Extract rate 160m 3 /hr or350m 3 /hr at free-airdischargeFans are in-duct mountedBritish madeDesigned to exceed the2006 Building Regulationson Ventilation(F1)dependant uponducting lengthTested to comply withHD280/BS3456 Part102:342 19882 year no quibbleguaranteeTechnical Data230V modelsCatalogue No. Type1004 Standard model - 2 speed for remote switching.1004 T Timer model - with integral over-run timer (15 mins).1005 Standard model - 2 speed for remote switching.ConstructionElectricalMotorGuaranteeInstallationThese fans are moulded in impact resistant high gloss ABS thermoplastics for strength,durability and finish.220-230V ~ A.C. 50Hz Single phase consuming 35 / 56 watts. These fans are doubleinsulated and do not require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mm inall poles, must be used with a 3 amp fuse fitted.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free<strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The range is designed to be duct mounted.A full range of ducting accessories is available – contact sales@ferrob.co.uk<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukSept06


PerformanceAdditional Data1004 / 1004 T - extract rate of 160m³/hr (at free-air discharge)1005 – extract rate of 350m³/hr (at free-air discharge)Maximum pressure: see graph below. Fan speed: 2400 r.p.m.Sound volume: 40.0 dB(A) Maximum operating temperature 40ºC.1004 1005D D1 L H1004 / 1004T 96 136 260 1951005 / 1005T 123 136 240 195<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukSept06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Cooker HoodTo compliment the existing range ofventilation products, <strong>Ferrob</strong> are now ableto offer a newly-developed range ofcooker hoods for domestic kitchens.Having two colours across two modelsenables <strong>Ferrob</strong> to fully ventilate aproperty whatever the circumstances tosuit all tastes.All units come in either white or brownwith integral grease filters, 3-speed switchand light.Extract Ratemaximum180m 3 /hrLow Running CostsBritish Made2 year no quibbleguaranteeMeets BuildingRegulations 20063-speed operation asstandardTechnical DataEasy to installQuiet in operationCatalogue No.CK100CK100TTypeComplete with 3-speed manual switch.As above but with over-run timer for internal kitchens.Both models carry a suffix of W for white or B for brown.ConstructionElectricalMotorGuaranteeInstallationThese units are made of strong and durable powder-coated steel for strength, durability andfinish.220-230V ~ A.C. 50Hz Single phase consuming 90 watts when on fast speed and 27 watts onslow continuous speed. These units require an earth. All wiring must comply with current IEEregulations. A double pole isolating switch, having a contact separation of at least 3mm in allpoles, must be used with a 3 amp fuse fitted.Single phase three-speed induction motor with pre-oiled ball-bearings for a long maintenancefree <strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The units are designed to be mounted above the cooker or hob. It is recommended that theunit is ducted out through the wall or through flat ducting if the hood is on an internal wall.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukSept06


PerformanceAdditionalDataCK100 / CK100T - Maximum Extract Rate 180m 3 /hrMaximum pressure: 50 pa.Noise level - full speed: 25.0 dB(A).Maximum operating temperature: -40ºC.Unit Dimensions: -W 600, D 500, H 150<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukSept06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Light Commercial 230 & 300The Light Commercial range of units is designedfor use in numerous applications including offices,bars, hairdressers, restaurants, classrooms,laboratories, laundries and small workshops.The Light Commercial range with axial fans of230mm and 300mm sizes is designed for a widerange of commercial applications. All fansincorporate automatic, electronically actuatedshutters allowing quick and quiet operation.High Extract ratesFans can be wall, orwindow mountedBritish made2 year no quibbleguaranteeAll models can be operated through a remote switch or wired to a ReversibleControl unit allowing air to be extracted from or supplied to the room / area.The fans also have mains-on neon indicators giving clear visual reference of eachstage of the fan’s operation.Features and BenefitsWall or window mountedAutomatic silent shuttersVariable speed (when used with a reversible controller – supplied separately)Technical DataConstructionElectricalMotorGuaranteeInstallationThese fans are moulded in impact resistant high gloss ABS thermoplastics forstrength, durability and finish.220-230v ~ A.C. 50Hz Single phase. These fans are double insulated and do notrequire an earth. All wiring must comply with current IEE regulations. A doublepole isolating switch, having a contact separation of at least 3mm in all poles, mustbe used with a 3 amp fuse fitted. The fan should be mounted a minimum of 1.75metres from the floor.Do not install the fan above a heat source, e.g. cooker or radiator.Single phase induction motor with pre-oiled bearings fitted for a long maintenance free<strong>life</strong> and protected by a thermal fuse.Two year no quibble guarantee.The fans are designed to be wall or window mounted. Kits available on request.Wall kits comprise a flexible wall sleeve and a fixed external grille in white.Window kits comprise a fixed external white grille.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan06


Performance Graph – LC 230 RVTechnical DataExtract VolumeSound VolumeVoltageFrequencyWattageMax TempWeightMax PressureIP Rating:280 m 3 /hr – minimum750 m 3 /hr – maximum47.4dBa @ 3m220 – 230 v AC50Hz40W50 0 C3.7 Kg70 paIPx4Unit Dimensions & cut outsA 321B 331C 141D 30Ø 230Hole sizes:Wall/WindowGlass254-262 mm4 - 48 mmPerformance Graph – LC 300 RVTechnical DataExtract VolumeSound VolumeVoltageFrequencyWattageMax TempWeightMax PressureIP Rating:600 m 3 /hr – minimum1,350 m 3 /hr – maximum51 dBa @ 3m220 – 230 v AC50Hz75W50 0 C6.6 Kg110 paIPx4Unit Dimensions & cut outsA 375B 385C 148D 30Ø 300Hole sizes:Wall/WindowGlass324-337 mm4 - 48 mm<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukJan06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Rem ote Control UnitsDigital controller D 1007If a property has recently had afan installed, it is possible toenhance the existing installationwith a unit from thecomprehensive range ofRemote Controllers.These controllers aremanufactured using all theunique features of the electronic circuitry that is contained within our fanunits - but housed within a single or double-gang box.Wall mountedSelf-cleaning humiditysensorEnergy SavingManual pullcord over-ride2-light status or digitaldisplayInfra-red humidity read-outDownload FacilityEasy to installVariable Fan Speed controller - 1414The variable non-reversing fan speed controller is suitable forcontrolling the speed of fans providing that the electrical load is notless than 20watts or more than 200watts.The controller fits <strong>into</strong> a single pattress not less than 20mm deep.Model RangeCatalogue No. Type1414 variable fan speed controllerD 1007with self-calibrating sensor, digital display and manual pull switchL 1007with self-calibrating sensor, digital display, manual pull switch and download facilityM 1007with self-calibrating sensor, 2-light status and manual pull switchUAX 1007 Remote humidity controller<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


ConstructionElectricalGuaranteeInstallationThese units are made of strong and durable self-extinguishing plastic for strength, durabilityand finish.220-230V ~ A.C. 50Hz. These units do not require an earth. All wiring must comply withcurrent IEE regulations. A double pole isolating switch, having a contact separation of atleast 3mm in all poles, must be used with a 3 amp fuse fitted.Two year no quibble guarantee.The units are designed to be wall mounted not less than 300mm from ceiling.Do not install above a heat source e.g. cooker, radiator.<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukMar07


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Cosivent – Passive Ventilation UnitVentilation cannot work properly in a property if replacement air isnot supplied to the building.To aid control of condensation and hence reduce high humiditylevels and prevent mould growth, <strong>Ferrob</strong> would recommend theuse of a Cosivent in room(s) that need ventilating without fitting anelectrical ventilation unit.These are usually fitted in bedrooms and / or lounges etc toenable air to be drawn <strong>into</strong> the property when the extract fans areon. This has the effect of ventilating the extra rooms which iswhere, invariably, humidity will settle.When the extract fans, which are normally installed to the wet rooms (kitchen, bathrooms etc), are not running, airwill not be drawn <strong>into</strong> the house and hence no draughts are experienced by the resident.Filters are fitted to the units to remove dust and dirt particles and prevent them from entering the home.Catalogue No.CV100Type100mm CosiventGuaranteeInstallationTwo year no quibble guaranteeThe units are designed to be wall mounted at either high or low level and are supplied with anexternal grille (colours to suit).Page 1 of 1<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>Tumble Dryer VentTo aid control of condensation and hence reduce high humidity levelsand prevent mould growth, <strong>Ferrob</strong> would recommend the use of aTumble Dryer vent to an outside wall.These vents are usually fitted in kitchens and / or utility rooms etc toenable damp air from the dryer to escape from the property.Catalogue No.TDR 100Type100mm Tumble Dryer VentGuaranteeInstallationTwo year no quibble guaranteeThe units are designed to be wall mounted at either high or low level and are supplied with anexternal grille (colours to suit).<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.ukNov06


eathing <strong>life</strong> <strong>into</strong> <strong>your</strong><strong>environment</strong>General AccessoriesA full range of accessories is available from <strong>Ferrob</strong> to complement the product range. All products come in 100mm and150mm diameter sizes and all grilles are available in 5 colours (terracotta, white, grey, beige and brown).Flexible ducting FD100/125/150 Fixed wall grilles FG100/150 Gravity wall grilles GG100/150Backdraught shutters BS100/150 Condensation Traps CT100/150 Domed weather cowls DWC100/150Fire dampers FDR100/150 Internal cowls IC100/150 Metal wall cowls WLC100/150Duct reducers RED100/150 Wall cowls CG100/150 Wall plates WP100-150Page 1 of 1<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk


Wall sleeves WS100/150 Window cowls CG100/150WW Window grilles WG100/150Page 2 of 1<strong>Ferrob</strong> Limited, Regency House, Kingsclere Park, Kingsclere, Newbury, Berks. RG20 4SW; Tel: 01635 299266 Fax: 01635 299277Email: sales@ferrob.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!