12.07.2015 Views

Download Tender Document Corrigendum - Western Railway ...

Download Tender Document Corrigendum - Western Railway ...

Download Tender Document Corrigendum - Western Railway ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7 SPI complete with unit post CI based hood cover etc. No 4 3167.25 12669.008ARA terminal block as per Drg. No. SA-23741-A, Alt IV made ofPBT / Poly Carbonate as per spcn no. IRS.S.75/2006 (Rev.2)No 1000 63.96 63960.009Low-tension Power Panel suitable for three single phasesupplies as per Drawing No. DRM/SG/743 . This includessupply of supply proving relays, neutral relays, MCBs, fuses &contactor units etc. This also includes supply of powerNo 2 118050.65 236101.30distribution panel as per schematic drawing. Item includessupply of 10 spare fuses of each type used in power panel &one contactor unit of each type as spare.10Power wire (Copper , multi stand ) as per IS 649/1990 (1*6sqmm) 85 Conductor each dia. 0.30 +/- 0.01 with insulationthickness of 1.55 mm normal conductor assistance 3.14KM 2 32709.38 65418.75ohms/km and test parameters as per IRS(S)76/89.11Power wire (Copper , multi stand ) as per IS 2465/1984 & IS649/1990 (1*16sq mm) 85 Conductor each dia. 0.45 +/- 0.01with insulation thickness of 1.2 mm normal conductorKM 1 102930.57 102930.57assistance 1.127 ohms/km and test parameters as perIRS(S)76/89.12Wire PVC single core flexible 28 x 0.12 single IS 694/77Finolex makemtr 2000 4.80 9600.0013Supply & Installation of Earth leakage Detectore of 12channels as per RDSO/SPN/256/2002 and latest.No 2 107053.04 214106.0714B class G.I pipe 100mm dia (internal dia, 3.65mm +/- 10%thick) of IS specification 1239 of 1990 or latest with socket at Mtrs 100 522.68 52268.15on end and coupling. GI pipes shall have ISI mark on it.15Q series Neutral line A.C. Immune (QNA1) 24 V DCconforming BRS 931 A Confirguration 8F 8B complete with No 80 3648.94 291915.16plug board.16Supply of Double walled corugated (DWC) pipe with associatedcollars etc. as specification no. IS 14930 part-I & II or latest,anti-rodent and anti-oxidant and non-flame propagating typein 6 mtrs. straight length of size 120mm outer dia & 103 mmInner dia (the manufacturer, suppliers must produce valid ISlicence and should be certified under ISO 9000 and shallsubmit copy of certificate) The following required couplingarrangemetn should also be supplied:-No 30 1527.08 45812.461. Suitable snap fit couplers with rubber O-ring2. Spacers3. Tees4. Bend5. End Cap(1 no = 6 mtr straight pipe)length .17Key lock relays working on 60V D.C. AC immunized. With I K-50 neutral relay configuration to 4F/4B. Kay ward `Z' or as per No 30 5351.34 160540.23site requirement. Siemens make or similar.18 Electronic magneto phone as per IRS.TC.79/2000 or latest No 30 3003.66 90109.8019Cable marker hot dip galvanized as per Drg. no.CSTE/3644Page 9 of 11.No 400 227.75 91100.6020 Multimeter Fluke189 or simillar. Nos. 2 34107.28 68214.5621Supply of Digital multimeter 73402 Yokogawa make or similarwith acessories as per tech. specsNo. 2 44262.40 88524.80DRM (S&T)For and on behalf of President of India Page 4Signature of <strong>Tender</strong>er & Seal

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!