will not be consideredTENDER FORM (SECOND SHEET)Para 12:So as to reach his office not laterthan 15.00 hours of the 18/04/2011(Extended up to 09.05.2011) ordeposited in special box allotted forthe purpose with the officesuperintendent, at above mentionedoffice. This special box will be sealedat 15.00 hours of the 18/04/2011.(Extended up to 09.05.2011) Thetender will be opened at 15.30 hourson 18/04/2011 (extended up to09.05.2011).CHAPTER 2 Para 2.2 <strong>Tender</strong>s will besold up to 15.00 hrs. On 18/04/2011(Extended up to 09.05.2011). Sealedtenders will be received up to 15.00 hrson 18/04/2011 (Extended up to09.05.2011). Under no circumstances,the amount paid for the tender will berefunded. <strong>Tender</strong> form is nontransferable.CHAPTER 2 Para 2.4.1Any Relay Interlocking (RI) or ElectronicInterlocking (EI) or Colour LightSignaling (CLS) or Absolute / AutomaticBlock Signalling (ABS) or IntermediateBlock Signaling (IBS) work involvingOutdoor workCHAPTER 2 Para No. 2.10.2TENDER DUE TO OPEN ON: 18.04.2011(EXTENDED UP TO 09.05.2011).CHAPTER 2 Para No. 2.10.3The tender should be deposited in the<strong>Tender</strong> Box in the office of Sr. DivisionalSignal & Telecom Engineer (North), 2 ndFloor, Mumbai Central Station, <strong>Western</strong><strong>Railway</strong>, Mumbai-400008 before closing ofthe tender box at 15.00 hrs. On18.04.2011 (Extended up to 09.05.2011).will not be consideredTENDER FORM (SECOND SHEET)Para 12 :So as to reach his office not laterthan 15.00 hours of the 18/04/2011(Extended up to 27.06.2011) ordeposited in special box allotted forthe purpose with the officesuperintendent, at above mentionedoffice. This special box will be sealedat 15.00 hours of the 18/04/2011.(Extended up to 27.06.2011) Thetender will be opened at 15.30 hourson 18/04/2011 (extended up to27.06.2011).CHAPTER 2 Para 2.2<strong>Tender</strong>s will be sold up to 15.00 hrs. On18/04/2011 (Extended up to27.06.2011). Sealed tenders will bereceived up to 15.00 hrs on 18/04/2011(Extended up to 27.06.2011). Under nocircumstances, the amount paid for thetender will be refunded. <strong>Tender</strong> form isnon-transferable.CHAPTER 2 Para 2.4.1Any RI or EI or CLS or ABS or TPWS orIBS or any Track circuiting work or anyAFTC work or any axle counter workinvolving outdoor work.CHAPTER 2 Para No. 2.10.2TENDER DUE TO OPEN ON: 18.04.2011(EXTENDED UP TO 27.06.2011).CHAPTER 2 Para No. 2.10.3The tender should be deposited in the<strong>Tender</strong> Box in the office of Sr. DivisionalSignal & Telecom Engineer (North), 2 ndFloor, Mumbai Central Station, <strong>Western</strong><strong>Railway</strong>, Mumbai-400008 before closing ofthe tender box at 15.00 hrs. On18.04.2011 (Extended up to27.06.2011).DRM (S&T)For and on behalf of President of India Page 2Signature of <strong>Tender</strong>er & Seal


CHAPTER 4, Para 4.24 (vi)The Inspection Charges for the inspectionservice rendered to the S&T contractorsexecuting signaling works shall be borneby the contractorsCHAPTER 5,Para 5.22TECHNICAL SPECIFICATIONS FORINSULATION METER BMM2500MEGGER MAKE OR SIMILARCHAPTER 4, Para 4.24 (vi)The Inspection Charges for the inspectionservice rendered to the S&T contractors executing signaling works shall be borneby the <strong>Railway</strong>s.ITEM DELETED FROM TENDERSCHEDULE, HENCE PARA 5.22 MAY BETREATED AS DELETED.IN CHAPTER 6 (SCHEDULES OF MATERIAL AND WORK) should be replacedby the following Schedule:-.SCHEDULE OF MATERIAL & WORKName of work: Replacement of overaged outdoor signalling gears at Valsad in VR-STsection of Mumbai Division, <strong>Western</strong> <strong>Railway</strong>.<strong>Tender</strong> No. SG 217/2/156/WASr.No.DESCRIPTION UNIT QTY. RATE AMOUNT1.iiiiiiSchedule A : SupplySupply of Apparatus case(i)Apparatus case single NE Rly. As perDrg.No.W.Rly/SW/47/68.(ii)Apparatus case half NE Rly. As perDrg.No.W.Rly/SW/47/68.(iii) Minature `E' type lock complete with keys as per RDSODrg.No. SA 3473, 3373 & specn. IRS(S) 30/64. Ward to bespecified by Engineer - in - charge.No 40 13173.54 526941.60No 30 8443.19 253295.72No 140 1712.23 239712.552 Junction type Route indicator to IRS(S)66/84 as per drawings.i 1 way as per Drg. No. SA 23401 No 2 14197.89 28395.78ii 2 way as per Drg. No. SA 23402 No 3 15303.66 45910.9834Position light shunt signal unit suitable for LED, completepost. CI Base hood,cover etc. as per RDSO Drg. No.SA23840Position light shunt signal unit suitable for LED, complete withOff set bracket ,hood cover etc as per Drg.No. SA 23840No 22 3167.25 69679.50No 16 3127.89 50046.245 Calling on Signal Unit suitable for LED. No 3 2063.94 6191.826 Route indicator Multi lamp unit type as per Drg.No.23761 No 4 13617.00 54468.00DRM (S&T)For and on behalf of President of India Page 3Signature of <strong>Tender</strong>er & Seal


7 SPI complete with unit post CI based hood cover etc. No 4 3167.25 12669.008ARA terminal block as per Drg. No. SA-23741-A, Alt IV made ofPBT / Poly Carbonate as per spcn no. IRS.S.75/2006 (Rev.2)No 1000 63.96 63960.009Low-tension Power Panel suitable for three single phasesupplies as per Drawing No. DRM/SG/743 . This includessupply of supply proving relays, neutral relays, MCBs, fuses &contactor units etc. This also includes supply of powerNo 2 118050.65 236101.30distribution panel as per schematic drawing. Item includessupply of 10 spare fuses of each type used in power panel &one contactor unit of each type as spare.10Power wire (Copper , multi stand ) as per IS 649/1990 (1*6sqmm) 85 Conductor each dia. 0.30 +/- 0.01 with insulationthickness of 1.55 mm normal conductor assistance 3.14KM 2 32709.38 65418.75ohms/km and test parameters as per IRS(S)76/89.11Power wire (Copper , multi stand ) as per IS 2465/1984 & IS649/1990 (1*16sq mm) 85 Conductor each dia. 0.45 +/- 0.01with insulation thickness of 1.2 mm normal conductorKM 1 102930.57 102930.57assistance 1.127 ohms/km and test parameters as perIRS(S)76/89.12Wire PVC single core flexible 28 x 0.12 single IS 694/77Finolex makemtr 2000 4.80 9600.0013Supply & Installation of Earth leakage Detectore of 12channels as per RDSO/SPN/256/2002 and latest.No 2 107053.04 214106.0714B class G.I pipe 100mm dia (internal dia, 3.65mm +/- 10%thick) of IS specification 1239 of 1990 or latest with socket at Mtrs 100 522.68 52268.15on end and coupling. GI pipes shall have ISI mark on it.15Q series Neutral line A.C. Immune (QNA1) 24 V DCconforming BRS 931 A Confirguration 8F 8B complete with No 80 3648.94 291915.16plug board.16Supply of Double walled corugated (DWC) pipe with associatedcollars etc. as specification no. IS 14930 part-I & II or latest,anti-rodent and anti-oxidant and non-flame propagating typein 6 mtrs. straight length of size 120mm outer dia & 103 mmInner dia (the manufacturer, suppliers must produce valid ISlicence and should be certified under ISO 9000 and shallsubmit copy of certificate) The following required couplingarrangemetn should also be supplied:-No 30 1527.08 45812.461. Suitable snap fit couplers with rubber O-ring2. Spacers3. Tees4. Bend5. End Cap(1 no = 6 mtr straight pipe)length .17Key lock relays working on 60V D.C. AC immunized. With I K-50 neutral relay configuration to 4F/4B. Kay ward `Z' or as per No 30 5351.34 160540.23site requirement. Siemens make or similar.18 Electronic magneto phone as per IRS.TC.79/2000 or latest No 30 3003.66 90109.8019Cable marker hot dip galvanized as per Drg. no.CSTE/3644Page 9 of 11.No 400 227.75 91100.6020 Multimeter Fluke189 or simillar. Nos. 2 34107.28 68214.5621Supply of Digital multimeter 73402 Yokogawa make or similarwith acessories as per tech. specsNo. 2 44262.40 88524.80DRM (S&T)For and on behalf of President of India Page 4Signature of <strong>Tender</strong>er & Seal


Electric Drill machine working voltage 110V/AC 50C/s22 235Watt no load speed 700 RPM. Full load speed 250 RPM,Full load current 1.3A weight 2.6Kgs. WOLF make or simillarPortable electric grinder size 7", working voltage 110V AC.23Make black and Decker or similar.24 Supply of cable route tracer as per RDSO ref no. STT/Cablelocator/55L dt 07/05/2010 Tool set comprising of (1) Cableavoidance tool XD(2). Signal generator SG-V complete t withearth state ,direct connection lead and auxillary earthconnection lead (3) Signalling clamp (4)Carry Bag (5) Manual(6) Training for one day at user premises. Material will beaccepted after successful demo of equipment in user premises.Nos. 2 3617.60 7235.20No. 2 17388.80 34777.60No. 1 76609.00 76609.0025.i Supply of screw less mounted 2.5 sqmm 4 wire front entry, twoin put two out out, Disconnected cage clamp Terminal blockfor test and measurement. (Wago or Phoniex) as per siterequirement. as per specification no. RDSO/SPN/189/2004. Nos. 5000 115.52 577600.00The procurement should be done from RDSO recommendedsources. The colour wil be decided by the Engineer-in charge.(prefrebly in Blue, red & Grey in colour in the ratio 1:2:3)ii Supply of End plate for above item, 10mm/0.0394 in width asper site requirement. nos. 1000 21.28 21280.00iii Supply of End stopper for above item, 2.5mm/0.091 in thickas per site requirement. Nos. 1000 19.76 19760.00iv Supply of Carrier rails for above item, 35mm X 7.5mm, 1mmin thickness un-slotted type as per site requirement. Mtr. 350 193.04 67564.0026 Supply of Hylum sheet, resin bonded 10 mm thick, grade P3 instandard size of 1.22 x 1.22 mtr. As per spcn IS 2036 of 1974 Nos. 70 4060.23 284216.10or latestTOTAL for Schedule A3956955.5312Schedule 'B' EXECUTIONCasting of CC foundation for all types of apparatuscases.Casting of cement concrete foundation in the ratio 1:3:6for N.E. type A/case as per Drg. No.CSTE/5074. using std.size holding down bolts. Item includes excavation,ramming,curing and plastering with 1:4 cement - sand mixture(Aggregate not exceeding 3.8 cm).Plastering should be done to level the surface at sides 75 mmbelow the ground level after the cable is taken inside the A /case. Aggregate,cement, sand , holding down bolts, nuts to besupplied by contractor.(a) Single apparatus case.No40 8781.23 351249.20(b) Half apparatus case. No 30 4917.14 147514.16Installation of Apparataus cases with minature `E' type lockson CC foundation on grouted bolts. The item includes fitting ofE-type locks and fabrication of slotted angle frame and fixingthe same in location box as per Drg. given belowFilling the space enclosed below the location box with sandand fitting switch & holder for location light. Complete materialwill be contractor's own.This includes supply & fixing oftelephone sockets,location lamp holder and makingarrangements for pad locking of location boxes.(a) Single apparatus case. (Dy.CSTE/C/BCT/F/1097) No 40 986.47 39458.70(b) Half apparatus case. (Dy.CSTE/C/BCT/F/1097) No 30 591.50 17744.96DRM (S&T)For and on behalf of President of India Page 5Signature of <strong>Tender</strong>er & Seal


3Supply & fixing of hylam strips of size: 860 mm X 140 mm X10 mm for TF/TR wiring for NE single apparatus case.Thisincludes fixing of M6 terminals , ND type fuses on each strip.0 1686.07 0.00Two extra holes on either sides of M6 terminals/ ND type fusesto be drilled and two extra holes for fixng the strip.No4Fabrication of Hylum board of 10mm thick on the MS angleframe fixed in location box and fixing fuse blocks, fuses, bulbs,holders, switches, tele sockets and Q series relays with0.00suiitable arrangements.i Single Apparatus case Nos. 35 1965.54 68793.90ii Half Apparatus case Nos. 25 480.93 12023.255Fixing of Screwless/ARA/M-6 terminals and fuses blocks withprovision of holes on hylum sheets anad fixing by galvanisednuts and bolts. This includes provision of two additional holes1000 11.07 11070.00on the hylum board on either side for cable conductor entry.The work shall be done as per requirement of site.Nos.6Supply & fixing Hylum planks approx .25mm thickcommercially available make for keeping batteries, powerequipment etc. size to be obtained from Engineer in charge.2 75647.46 151294.92Commercially available thickness will be accepted as approvedby Engineer in charge.Cu.m7Costing of CC foundation for signal post. Casting of cementconcrete foundation in the ratio 1:3:6 as per Drg. No.CSTE/3122 using std. size holding down bolts for erection ofcolourlight signal post. Item includes excavation ramming,32 6560.55 209937.73curing and plastering with 1:4 cement-sand mixture (Aggregatenot exceeding 3:8 cm) Agregate, cemetn, sand and holdingdown boltss, nuts to be supplied by the contractor.No8Installation of CLS unit. The item includes errection of colourlight signal post with CI bases. Cis unit, Ladder with its base,ladder guards, platforms and MS sopporting bracket in themiddle of the ladder, hoods, current controller etc. it includesfixing and arrangement of extra accessories like pinacles, offsetbrackets, jn type route indicators (if any) 3 or 2 or 1 way etc.The item also includes termination of cables and wiring insidethe signal unit as per standard practice. Item includes supplyof number plates with photoluminiscent paint.It also includes provision & fising of maintainace platform asper design given by Engineer-in charge at site. Height of post3.5mtr. for loop line starters, advance starters distant signals,4.5 mtrs for main line starters & home, 5 mtrs. for Homesignal on curves. Decision of site in charge regarding height ofsignlas shall be final & binding on the contractor. The itemincludes cutting of signal post as per requirement by site incharge.(The signal units will be supplied by the railway)2/3/4 aspect signal unit mounted on offset bracket with Jni) type route indicators - 1/2/3 way on multi lamp route10 3414.48 34144.80indicators mounted on signals post.Noii) 2/3/4 aspect signal unit mounted directly on signals post. No 22 3050.40 67108.809Casting of CC foundation for position light shunt signal in theratio 1:3:6 as per Drg. No. Dy.CSTE/C/BCT/FOND/1087using std.size holding down bolts,nuts,Items includes26 4481.30 116513.74excavation,ramming,cutting,plastering, 1:4 cement sandmixture(Aggregate cement sandNo10Erection of position light shunt signal unit/SPI. CLS post, CIbase, pinacles, arrow etc. is covered in sch.'A'No.26 1876.98 48801.48DRM (S&T)For and on behalf of President of India Page 6Signature of <strong>Tender</strong>er & Seal


18Digging of cable trench 0.3 mtr deep,0.3 mtr wide on Asphaltedplatform /road. Refilling with earth leveling of trenches& restoring the original surfaces on trenches. The itemincludes covering of cables by sieved soil for depth of 5 Cms.90 401.43 36128.93before covering by bricks / trunking / capping (Laying of brick/ trunking / capping is covered in Sch. `B' separately.) Cum19Termination of outdoor cables,main cables laid in locationboxes, Cable termination rack etc at both ends. Both ends ofa cable core terminated shall be counted as one terminal.Theitem includes dressing of cables,making wiring tree etc. Thisincludes all associated works of pulling out the cable from5000 1.6385 8192.50underground. hte item includes dressing of cables, makingwiring tree etc. The work shall be done as per location plansand instruction of rly engineer at site.No.20Laying of S&T Cables of various cores/pairs/quads intrenches/GI pipes/RCC pipes/trunking. This also includeslaying of cables in track crossings & road crossings. Itemincludes provision of labels on each cable of coloured plasticadhesive tapes or any other identifiable material to give thecable number at each G.P.(Cables will be maggered before and20000 6.554 131080.00after its laying by contractor under supervision of<strong>Railway</strong>Representative and he will submit the maggeringreportof each testing.)Length of the cable laid includes the length ofthe cable coiled for termination purposes.Km21 Fixing of B class GI pipes (ISI mark) 100mm dia or other dia,troughing on culverts bridges & any other loc. etc. includingmaterial for fixing arrangements as directed by Engineer incharge.(Supply of GI pipes, troughing is covered in Sch A.)Rm 100 176.96 17695.80Other dia pipes will be supplied by <strong>Railway</strong>s where feltnecessary by the Engineer-in-charge.22 Supplying and placing of one layer of standard size of `B' gradequality bricks of the local make spreading on cables laid.i lengthwise ( upto 2 cables). RM 4000 11.4695 45878.00ii widthwise ( more than 2 cables)RM 12000 24.5775 294930.0023 Supply & fixing laminated sheets 12 mm thick commercialllyavailable make keeping batteries, power equipment etc. size tobe obtained from Engg - in- charge. Commercially availablethickness will be accepted as approved by Engineer in charge.Sq.mtr.10 2262.92 22629.20TOTAL for Schedule B 2369375.12TOTAL for Schedule A & B 6326331Note:1)The material will be supplied as per technical specification & special condition of contract.Material whichare based with IRS/RDSO specifications, The latest specification of the same will be considered & materialwill be accepted after competent inspection authority.2) Except the amount printed in rates, sub-total & total amount of above schedule of work, if at any place intender documents any mistakes due to printing will be found in description of items, specifications,drawing, etc. & terms & conditions in tender document, the <strong>Railway</strong> has full power to rectify the samewhich will be binding for Contractor to agree the same after rectification. In this regard, the decesion of<strong>Railway</strong> will be final and no any argument will be accepted from Contractor side.3) <strong>Tender</strong>er/s shall not quote for individual items mentioned in schedule of work. So, the tenderermust quote his offer above / below on total estimated cost of tender which is described in certificate belowonly. If any tenderer quotes the rates for individual items, his offer shall be summarily rejected.DRM (S&T)For and on behalf of President of India Page 8Signature of <strong>Tender</strong>er & Seal


4) Those tenderer should apply who has compeleted similar type of work which means any Signalling &Telecummunication work successfully in any government sector / Indian <strong>Railway</strong>.5) <strong>Tender</strong>er should go with special condition and technical specification of the work carefully before quotingthe rate. They must be able to supply the material as per specification desired by <strong>Railway</strong>s. However,<strong>Railway</strong> has full power to change / delete the specification if require in interest of <strong>Railway</strong>. In this regard,the decision of <strong>Railway</strong> will be final which will be binding to the Contractor.6) If tenderer quoted his rates without mentioning ABOVE / BELOW, it will treated as BELOW only and noanyargument will be accepted from Contractor side.7)<strong>Tender</strong>er/s should sign the following certificate.I/We offer and agree to execute the above work at*________% (in figure) ______________________%(in words) above / below the total estimated cost of Rs. 63,26,331/- (Rs. Sixty three Lakh twentysix Thousand three Hundred thirty one Only)(* Write percentage both in figure and in words.)Signature of the <strong>Tender</strong>er with SealFor & on behalf of the President of IndiaDivisional <strong>Railway</strong> ManagerMumbai central, <strong>Western</strong> <strong>Railway</strong>END OF CORRIGENDUM DOCUMENTDRM (S&T)For and on behalf of President of India Page 9Signature of <strong>Tender</strong>er & Seal