SUB-20 User Manual - Dimax
SUB-20 User Manual - Dimax
SUB-20 User Manual - Dimax
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
41<strong>SUB</strong>-<strong>20</strong><strong>SUB</strong>-<strong>20</strong> APIError Codes3.7.8 Fast PWMFast PWM outputs are available on SPI header pins 4,6,8 (see SPI Header). Outputs are referenced asFPWM_0, FPWM_1 and FPWM_2. All three outputs share the same PWM generation module in <strong>SUB</strong>-<strong>20</strong> andhave the same PWM frequency but separate duty cycle configuration.Fast PWM frequency range is 8Mhz .. 0.238Hz. Duty cycle precision is 2..16 bits depending on the PWMfrequency.Functionssub_fpwm_configsub_fpwm_set© <strong>20</strong>13 xdimax.com rev 2.17